Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Idioma
Intervalo de año de publicación
2.
Tsitologiia ; 30(12): 1449-53, 1988 Dec.
Artículo en Ruso | MEDLINE | ID: mdl-2470176

RESUMEN

A cytofluorometric study was made of the total glycogen and its of fractions in liver cells of patients with hard mechanic trauma with or without intoxication. For studying glycogen dynamics in the course of traumatic illness, the aspiration biopsy material was obtained (30 patients) using repeated liver biopsy of one and the same patient. The total glycogen was found to change insignificantly in liver cells of patients with traumatic illness, both under favourable conditions and with intoxication, and at the normal level. The labile glycogen fraction in liver cells of patients with traumatic illness without intoxication is contained almost at the normal level (80-95%) of the total glycogen and is not changed for a long time. At that time the relative content of the labile glycogen fraction decreases appreciably in some cases to 45-50% due to intoxication development. A relative content of the labile glycogen fraction in hepatocytes with hard mechanical intoxication correlates well with the degree of intoxication. This makes hepatocyte glycogen microfluorometry a diagnostic tool in measuring the functional state of liver in the course of intoxication.


Asunto(s)
Glucógeno Hepático/análisis , Heridas y Lesiones/metabolismo , Biopsia con Aguja , Citofotometría , Humanos , Hígado/patología , Choque Traumático/metabolismo , Coloración y Etiquetado/métodos
5.
Tsitologiia ; 26(4): 490-3, 1984 Apr.
Artículo en Ruso | MEDLINE | ID: mdl-6377627

RESUMEN

Destruction of human peripheral blood leukocytes by toxins has been studied with the aid of an automatic microimage analyzer the "Morphoquant". The most informative parameters which define destruction stages have been revealed: the area and number of fragments of nucleus images and their distance to the nucleus centre under different levels of the optical threshold. Software for morphological analysis of leukocytes has been developed in addition to their classification using four destruction stages. The results of computerized classification of blood smears will compare with those obtained by a working haemotologist (85% coincidence).


Asunto(s)
Leucocitos/clasificación , Autoanálisis/instrumentación , Técnicas Citológicas/instrumentación , Humanos , Leucocitos/efectos de los fármacos , Minicomputadores , Toxemia/sangre , Toxinas Biológicas/toxicidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA