Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 113(11): 118102, 2014 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-25260008

RESUMEN

We use standing surface acoustic waves to induce coherent phonons in model lipid multilayers deposited on a piezoelectric surface. Probing the structure by phase-controlled stroboscopic x-ray pulses we find that the internal lipid bilayer electron density profile oscillates in response to the externally driven motion of the lipid film. The structural response to the well-controlled motion is a strong indication that bilayer structure and membrane fluctuations are intrinsically coupled, even though these structural changes are averaged out in equilibrium and time integrating measurements. Here the effects are revealed by a timing scheme with temporal resolution on the picosecond scale in combination with the sub-nm spatial resolution, enabled by high brilliance synchrotron x-ray reflectivity.

2.
Phys Med Biol ; 57(16): 5309-23, 2012 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-22853964

RESUMEN

We have analyzed the model organism Caenorhabditis elegans with the help of phase-contrast x-ray tomography. This work combines techniques from x-ray imaging studies of single biological cells by in-line holography with three-dimensional reconstruction and furthermore extends these studies to the multicellular level. To preserve the sub-cellular ultrastructure of the nematodes, we used the near-native sample preparation of high-pressure freezing as commonly used in the field of electron microscopy. For the presented samples, a standard, non-magnifying parallel-beam setting, as well as a magnifying, divergent-beam setting using nanofocusing optics is evaluated based on their tomographic reconstruction potential. In this paper, we address difficulties in sample preparation and issues of image processing. By experimental refinement and through optimized reconstruction procedures, we were able to perform x-ray imaging studies on a living specimen.


Asunto(s)
Caenorhabditis elegans/ultraestructura , Tomografía Computarizada por Rayos X/métodos , Animales , Caenorhabditis elegans/citología , Criopreservación , Imagenología Tridimensional , Tomografía Computarizada por Rayos X/instrumentación
3.
J Synchrotron Radiat ; 19(Pt 1): 30-8, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22186641

RESUMEN

The new third-generation synchrotron radiation source PETRA III located at the Deutsches Elektronen-Synchrotron DESY in Hamburg, Germany, has been operational since the second half of 2009. PETRA III is designed to deliver hard X-ray beams with very high brilliance. As one of the first beamlines of PETRA III the high-resolution diffraction beamline P08 is fully operational. P08 is specialized in X-ray scattering and diffraction experiments on solids and liquids where extreme high resolution in reciprocal space is required. The resolving power results in the high-quality PETRA III beam and unique optical elements such as a large-offset monochromator and beryllium lens changers. A high-precision six-circle diffractometer for solid samples and a specially designed liquid diffractometer are installed in the experimental hutch. Regular users have been accepted since summer 2010.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA