Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 10(16)2021 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-34441837

RESUMEN

Additively manufactured subperiosteal jaw implants (AMSJI) are patient-specific, 3D-printed, titanium implants that provide an alternative solution for patients with severe maxillary bone atrophy. The aim of this study was to evaluate the bony remodeling of the maxillary crest and supporting bone using AMSJI. Fifteen patients with a Cawood-Howell Class V or greater degree of maxillary atrophy were evaluated using (cone beam) computed tomography scans at set intervals: one month (T1) and twelve months (T2) after definitive masticatory loading of bilateral AMSJI implants in the maxilla. The postoperative images were segmented and superimposed on the preoperative images. Fixed evaluation points were determined in advance, and surface comparison was carried out to calculate and visualize the effects of AMSJITM on the surrounding bone. A total mean negative bone remodeling of 0.26 mm (SD 0.65 mm) was seen over six reference points on the crest. Minor bone loss (mean 0.088 mm resorption, SD 0.29 mm) was seen at the supporting bone at the wings and basal frame. We conclude that reconstruction of the severely atrophic maxilla with the AMSJI results in minimal effect on supporting bone. Reduced stress shielding with a biomechanically tuned subperiosteal implant does not induce radiographically significant crestal bone atrophy.

2.
Clin Oral Implants Res ; 28(1): 103-108, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26749417

RESUMEN

INTRODUCTION AND AIM: Buccal bone thickness is considered to be an important factor during implant surgery. Its resorption might have an effect on the soft tissue stability and eventually on implant survival. This study aimed to investigate the resorption of the buccal bone over the first 12 months after implant loading. MATERIALS AND METHODS: Twenty-four subjects (47 implants) were included. The buccal bone thickness was measured during implant surgery at several distances from the implant shoulder using a specifically designed device which allows buccal bone thickness measurements without the elevation of a muco-periostal flap. These measurements were repeated after 12 months of loading. Sixteen implants were placed flapless and 31 with the elevation of a flap. Of the latter, 19 were placed following a one-stage protocol and 12 following a two-stage protocol. RESULTS: The mean reduction in buccal bone thickness, when all groups pooled, was 0.26, 0.36, 0.35 and 0.27 mm at the shoulder and 2, 4 and 6 mm apically. Implants with initial bone thickness <1mm (thin buccal plate) did not lose significantly more bone than those with an initial thickness ≥1mm (thick bone plate) except in the 'open-flap, one-stage' group (P = 0.009). A flapless procedure leads to less bone resorption compared to an open-flap procedure (P = 0.03). However, the number of surgeries (one stage vs. two stages) did not influence the rate of bone resorption (P = 0.23). CONCLUSION: Within the limitations of this study, one might question the necessity of having a thick bone plate at the vestibular site of the implant.


Asunto(s)
Resorción Ósea , Implantación Dental Endoósea , Huesos Faciales/fisiología , Mejilla , Implantación Dental Endoósea/métodos , Huesos Faciales/anatomía & histología , Estudios de Seguimiento , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA