Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Diagn Interv Imaging ; 97(2): 203-9, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26282051

RESUMEN

PURPOSE: To assess the incidence and presentation of ipsilateral cancer recurrences (ICR) after deep inferior epigastric perforator (DIEP) flap reconstruction for breast cancer. PATIENTS AND METHODS: Data of 247 consecutive women with DIEP flap reconstruction after breast cancer in our institution between 1997 and 2009 were retrospectively reviewed. RESULTS: Mean follow-up time was 4.1years±3.2 (SD) (median: 3years; range: 1month - 14years). Thirty-one patients (12.5%, 95%CI: =8.7-17.3) presented 34 relapses, in average 4.1years±2.6 after mastectomy: 14 (41%) were ipsilateral, 6 (18%) contralateral and 14 (41%) metastatic. ICRs occurred earlier (3.9 vs. 5.8years; P<0.05) than non-ICRs. Most ICRs (10/14, 71%) involved the periphery of the flap and presented as palpable nodules. The remaining (4/14, 29%) involved the axilla and 3/4 (75%) were palpable. Imaging procedures detected infra-clinical ICRs in 3 of 10 imaged patients (30%). CONCLUSION: ICRs after DIEP flap reconstruction are more frequent than contralateral recurrences suggesting the need for imaging follow-up of the reconstructed breast.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología , Mamoplastia/métodos , Mamografía , Neoplasias Primarias Secundarias/diagnóstico por imagen , Neoplasias Primarias Secundarias/epidemiología , Colgajo Perforante , Adulto , Anciano , Neoplasias de la Mama/cirugía , Femenino , Humanos , Incidencia , Persona de Mediana Edad , Estudios Retrospectivos
2.
Diagn Interv Imaging ; 96(9): 931-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25908324

RESUMEN

PURPOSE: To evaluate using phantom study the average glandular dose (AGD) and image quality in breast tomosynthesis. MATERIALS AND METHODS: The study was performed with a full-field digital mammography system (Mammomat Inspiration(®), Siemens, Erlangen, Germany) combined with tomosynthesis equipment (3D). For AGD evaluation, polymethyl methacrylate (PMMA) plates and a dosimeter were used to directly measure the absorbed doses in 2D and in 3D. The doses were then compared to the doses displayed on the equipment using the Mann-Whitney test. Three phantoms, accredited for 2D digital mammography (MTM 100, ACR RMI 156, BR3D), were imaged three times in 2D then in 3D. For each acquisition, the AGD was recorded. For image quality assessment, scores, defined by the rate of visible inserts, obtained for each acquisition both in 2D and in 3D, and for each phantom, were compared (Kruskall-Wallis and post-hoc Dunn tests). RESULTS: There was no significant difference between the measured and displayed AGD, both in 2D and in 3D imaging (P>0.05). With identical acquisition parameters, AGD were significantly greater in 3D than in 2D P<0.01). For phantoms MTM 100 and ACR RMI 156, there was no significant difference between the rate of visible inserts in 2D and in 3D (P=0.06 and P=0.36, respectively). However for phantom BR3D, the rate was significantly higher in 3D than in 2D (P<0.0001). CONCLUSION: Doses are significantly greater in 3D than in 2D. With tomosynthesis, out of the three phantoms tested, only phantom BR3D showed a higher rate of visible inserts.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Mamografía/métodos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Radiometría , Femenino , Francia , Humanos , Control de Calidad , Dosis de Radiación , Sensibilidad y Especificidad
3.
Ann Oncol ; 24(8): 2023-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23616280

RESUMEN

BACKGROUND: Recent data from ACOSOG Z0011 and NSABP B32 trials suggested no need for axillary lymph node dissection (ALND) in patients with micrometastatic involvement of the sentinel lymph node (SLN). The low rate of axillary recurrence was attributed to the axilla coverage by the tangential fields (TgFs) irradiation and systemic therapy. This study aimed to evaluate dose distribution and coverage of the axilla levels I-II and the SLN area. PATIENTS AND METHODS: One hundred and nine patients were analyzed according to three groups: group 1 (50 Gy; n = 18), group 2 (60 Gy; n = 34) and group 3 (66 Gy; n = 57). Patients were treated using the standard (STgF; n = 22) or high (HTgF; n = 87) TgF. RESULTS: The median doses delivered to level I using HTgF versus STgF were 33 and 20 Gy (P = 0.0001). The mean dose delivered to the SLN area was only 28 Gy. Additionally, the SLN area was totally included in the HTgF in 1 out of 12 patients who had intraoperative clip placement in the SNL area. CONCLUSIONS: TgFs provide a limited coverage of the axilla and the SNLB area. This information should be considered when only TgFs are planned to target the axilla in patients with a positive SLN without ALND. Standardization of locoregional radiotherapy in this situation is urgently needed.


Asunto(s)
Neoplasias de la Mama/radioterapia , Metástasis Linfática/radioterapia , Recurrencia Local de Neoplasia/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Axila , Neoplasias de la Mama/mortalidad , Femenino , Humanos , Ganglios Linfáticos/efectos de la radiación , Persona de Mediana Edad , Estudios Prospectivos , Dosificación Radioterapéutica , Sobrevida , Tasa de Supervivencia
4.
J Radiol ; 91(3 Pt 2): 375-80, 2010 Mar.
Artículo en Francés | MEDLINE | ID: mdl-20508572

RESUMEN

Hemato-oncologic imaging combines anatomical and functional imaging data for optimal staging and follow-up of patients. It is currently possible to achieve high spatial resolution and functional evaluation at whole body MR imaging. Functional imaging may be achieved with two techniques: dynamic imaging following intravenous contrast injection and diffusion-weighted imaging. The purpose of this article is to demonstrate how both functional imaging techniques can be combined with whole body MR imaging for the evaluation of multiple myeloma and lymphomas.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias Hematológicas/diagnóstico , Imagen por Resonancia Magnética/métodos , Imagen de Cuerpo Entero/métodos , Medios de Contraste , Estudios de Seguimiento , Humanos , Aumento de la Imagen/métodos , Linfoma/diagnóstico , Mieloma Múltiple/diagnóstico , Estadificación de Neoplasias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA