Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Radiat Environ Biophys ; 57(4): 357-363, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30324495

RESUMEN

Otoliths are the organs which fish use for hearing and keeping balance. Otoliths are the most calcified tissues in the fish body. In contrast to bones, otoliths are not affected by remodeling and, therefore, they are expected to accumulate any dose from ionizing radiation during lifetime. Therefore, EPR dosimetry with fish otoliths could be an important tool for dose reconstruction in radiobiology and radioecology. It could also provide useful information remediation actions to de-contaminate waterbodies. Consequently, in the present study, otoliths of three contaminated fish species (roach (Rutilus rutilus), pike (Esox lucius) and perch (Perca Fluviatilis)) were examined with Electron Paramagnetic Resonance (EPR) spectroscopy. The fish were caught at storage reservoirs of liquid radioactive waste from Mayak PA and from the upper reach of the Techa River, which have been contaminated with different levels of radionuclide activity concentrations. It is shown that the radiation-induced EPR signal of otolith is stable and characterized by a linear dose response. However, the slope of the calibration curve (corresponding to the radiation sensitivity of the material) is not the same for different species; this may be caused by differences in mineralization. The reconstructed doses were found to be in the range from undetectable (in fish from the upper stream of the Techa River) up to 265 Gy (in roach from the most contaminated waterbody). In parallel, otoliths were measured with ß-counter to detect 90Sr/90Y. Samples were also tested on the presence of alpha-emitters, but no alpha activity above background could be detected. However, a significant activity concentration of 90Sr was detected (from 1 × 101 to 2 × 104 Bq/g). The EPR doses measured correlated with the 90Sr activity concentration measured in the otolith samples.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón , Membrana Otolítica/efectos de la radiación , Radiometría/métodos
2.
Radiat Prot Dosimetry ; 120(1-4): 176-83, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16702247

RESUMEN

The objective of the Third International Intercomparison on EPR Tooth Dosimetry was to evaluate laboratories performing tooth enamel dosimetry <300 mGy. Final analysis of results included a correlation analysis between features of laboratory dose reconstruction protocols and dosimetry performance. Applicability of electron paramagnetic resonance (EPR) tooth dosimetry at low dose was shown at two applied dose levels of 79 and 176 mGy. Most (9 of 12) laboratories reported the dose to be within 50 mGy of the delivered dose of 79 mGy, and 10 of 12 laboratories reported the dose to be within 100 mGy of the delivered dose of 176 mGy. At the high-dose tested (704 mGy) agreement within 25% of the delivered dose was found in 10 laboratories. Features of EPR dose reconstruction protocols that affect dosimetry performance were found to be magnetic field modulation amplitude in EPR spectrum recording, EPR signal model in spectrum deconvolution and duration of latency period for tooth enamel samples after preparation.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón/métodos , Odontología Forense/métodos , Radioisótopos/análisis , Radiometría/métodos , Diente/química , Espectroscopía de Resonancia por Spin del Electrón/tendencias , Odontología Forense/tendencias , Humanos , Radiometría/tendencias , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Appl Radiat Isot ; 62(2): 163-71, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15607443

RESUMEN

The objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 11 molars, which were cut into two halves. One half of each tooth was irradiated in a 60Co beam to doses in the ranges of 30-100 mGy (5 samples), 100-300 mGy (5 samples), and 300-900 mGy (1 sample). Fourteen international laboratories participated in this intercomparison programme. A first analysis of the results and an overview of the essential features of methods applied in different laboratories are presented. The relative standard deviation of results of all methods was better than 27% for applied doses in the range of 79-704 mGy. In the analysis of the unirradiated tooth halves 8% of the samples were identified as outliers with additional absorbed dose above background dose.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón/métodos , Espectroscopía de Resonancia por Spin del Electrón/normas , Radiometría/métodos , Radiometría/normas , Estándares de Referencia , Diente/química , Diente/efectos de la radiación , Benchmarking/métodos , Carga Corporal (Radioterapia) , Humanos , Técnicas In Vitro , Internacionalidad , Garantía de la Calidad de Atención de Salud/métodos , Garantía de la Calidad de Atención de Salud/normas , Dosis de Radiación , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo/métodos , Medición de Riesgo/normas , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA