Pacing Clin Electrophysiol ; 44(5): 814-823, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33738812

RESUMEN

RATIONALE: Coronavirus disease 2019 (COVID-19) is associated with many clinical manifestations including respiratory failure and cardiovascular compromise. OBJECTIVES: We examine outcomes in critically ill individuals with COVID-19 who develop atrial tachyarrhythmias. METHODS: We collected data from electrocardiograms and the electronic medical record of COVID-19 positive (COVID+ ) and negative (COVID- ) individuals admitted to our medical intensive care unit between February 29 and June 28, 2020. We compared clinical and demographic characteristics, new onset atrial tachyarrhythmia, hemodynamic compromise following atrial tachyarrhythmia, and in-hospital mortality in COVID+ versus COVID- . Hemodynamic compromise was defined as having a new or increased vasopressor requirement or the need for direct current cardioversion for hemodynamic instability within 1 hour of atrial tachyarrhythmia onset. RESULTS: Of 300 individuals included, 200 were COVID+ and 100 were COVID- . Mean age was 60 ± 16 years, 180 (60%) were males, and 170 (57%) were African American. New onset atrial tachyarrhythmia occurred in 16% of COVID+ and 19% of COVID- individuals (P = .51). When compared to COVID- participants without atrial tachyarrhythmia, COVID+ individuals with new onset atrial tachyarrhythmia had higher mortality after multivariable adjustment (OR 5.0, 95% CI 1.9-13.5). New onset atrial tachyarrhythmia was followed by hemodynamic compromise in 18 COVID+ but no COVID- participants (P = .0001). COVID+ individuals with hemodynamic compromise after atrial tachyarrhythmia required increased ventilatory support at the time of atrial tachyarrhythmia onset. CONCLUSIONS: Atrial tachyarrhythmia is associated with increased mortality in critically ill individuals with COVID-19, especially those mechanically ventilated. Recognition of this could assist with clinical care for individuals with COVID-19.


Asunto(s)
COVID-19 , Enfermedad Crítica , Adulto , Anciano , Arritmias Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , SARS-CoV-2 , Taquicardia
4.
J Cardiovasc Electrophysiol ; 28(5): 552-558, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28181727

RESUMEN

BACKGROUND: Real-time estimated longevity has been reported in pacemakers for several years, and was recently introduced in implantable cardioverter-defibrillators (ICDs). OBJECTIVE: We sought to evaluate the accuracy of this longevity estimate in St. Jude Medical (SJM) ICDs, especially as the device battery approaches depletion. METHODS: Among patients with SJM ICDs who underwent generator replacements due to reaching elective replacement indicator (ERI) at our institution, we identified those with devices that provided longevity estimates and reviewed their device interrogations in the 18 months prior to ERI. Significant discrepancy was defined as a difference of more than 12 months between estimated and actual longevity at any point during this period. RESULTS: Forty-six patients with Current/Promote devices formed the study group (40 cardiac resynchronization therapy [CRT] and 6 single/dual chamber). Of these, 34 (74%) had significant discrepancy between estimated and actual longevity (28 CRT and all single/dual). Longevity was significantly overestimated by the device algorithm (mean maximum discrepancy of 18.8 months), more in single/dual than CRT devices (30.5 vs. 17.1 months). Marked discrepancy was seen at voltages ≥2.57 volts, with maximum discrepancy at 2.57 volts (23 months). The overall longevity was higher in the discrepant group of CRT devices than in the nondiscrepant group (67 vs. 61 months, log-rank P = 0.03). CONCLUSIONS: There was significant overestimation of longevity in nearly three-fourths of Current/Promote SJM ICDs in the last 18 months prior to ERI. Longevity estimates of SJM ICDs may not be reliable for making clinical decisions on frequency of follow-up, as the battery approaches depletion.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Suministros de Energía Eléctrica , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Algoritmos , Remoción de Dispositivos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo