RESUMEN
(1) Objective: The aim of this study was to assess the biological behavior of bone tissue on a machined surface (MS) and modifications made by a laser beam (LS) and by a laser beam incorporated with hydroxyapatite (HA) using a biomimetic method without thermic treatment (LHS). (2) Methods: Scanning electron microscopy coupled with energy-dispersive X-ray spectrometry (SEM/EDX) was performed before and after installation in the rabbit tibiae. A total of 20 Albinus rabbits randomly received 30 implants of 3.75 × 10 mm in the right and left tibias, with two implants on each surface in each tibia. In the animals belonging to the 4-week euthanasia period group, intramuscular application of the fluorochromes calcein and alizarin was performed. In implants placed mesially in the tibiofemoral joint, biomechanical analysis was performed by means of a removal torque (N/cm). The tibias with the implants located distally to the joint were submitted for analysis by confocal laser microscopy (mineral apposition rate) and for histometric analysis by bone contact implant (%BIC) and newly formed bone area (%NBA). (3) Results: The SEM showed differences between the surfaces. The biomechanical analysis revealed significant differences in removal torque values between the MSs and LHSs over a 2-week period. Over a 4-week period, both the LSs and LHSs demonstrated removal torque values statistically higher than the MSs. BIC of the LHS implants were statistically superior to MS at the 2-week period and LHS and LS surfaces were statistically superior to MS at the 4-week period. Statistical analysis of the NBA of the implants showed difference between the LHS and MS in the period of 2 weeks. (4) Conclusions: The modifications of the LSs and LHSs provided important physicochemical modifications that favored the deposition of bone tissue on the surface of the implants.
RESUMEN
This study evaluated the bone incorporation process of a screw-shaped internal fixation device made of poly (L-lactide-co-D, L-lactide) (PLDLLA). Thirty-two male Wistar rats received 32 fixation devices (2 mm × 6 mm) randomly assigned to either the right or left tibia and one implant in each animal. After 7, 14, 28, and 42 days, the rats were euthanized and the specimens were subjected to microtomographic computed tomography (microCT) and histomorphometric analyses to evaluate bone interface contact (BIC%) and new bone formation (NBF%) in cortical and cancellous bone areas. The animals euthanized on days 28 and 42 were treated with calcein and alizarin red, and confocal LASER microscopy was performed to determine the mineral apposition rate (MAR). Micro-CT revealed a higher percentage of bone volume (p < 0.006), trabecular separation (p < 0.001), and BIC in the cortical (p < 0.001) and cancellous (p = 0.003) areas at 28 and 42 days than at 7 and 14 days. The cortical NBF at 42 days was greater than that at 7 and 14 days (p = 0.022). No statistically significant differences were observed in cancellous NBF or MAR at 28 and 42 days. Based on these results, it can be seen that the PLDLLA internal fixation device is biocompatible and allows new bone formation around the screw thread.
RESUMEN
This study aimed to develop a polymeric matrix of polyamide-6 (P6) impregnated with trimetaphosphate (TMP) nanoparticles and silver nanoparticles (AgNPs), and to evaluate its antimicrobial activity, surface free energy, TMP and Ag+ release, and cytotoxicity for use as a support in dental tissue. The data were subjected to statistical analysis (p < 0.05). P6 can be incorporated into TMP without altering its properties. In the first three hours, Ag+ was released for all groups decorated with AgNPs, and for TMP, the release only occurred for the P6-TMP-5% and P6-TMP-10% groups. In the inhibition zones, the AgNPs showed activity against both microorganisms. The P6-TMP-2.5%-Ag and P6-TMP-5%-Ag groups with AgNPs showed a greater reduction in CFU for S. mutans. For C. albicans, all groups showed a reduction in CFU. The P6-TMP groups showed higher cell viability, regardless of time (p < 0.05). The developed P6 polymeric matrix impregnated with TMP and AgNPs demonstrated promising antimicrobial properties against the tested microorganisms, making it a potential material for applications in scaffolds in dental tissues.
RESUMEN
A abrasão dos dentes artificiais utilizados nos tratamentos reabilitadores protéticos é de grande preocupação para o CD, uma vez que altera a DVO podendo desencadear distúrbios crânio-mandibulares, diminui a eficiência mastigatória, aumenta o desconforto do paciente e prejudica a estética. Por isso umas das mais importantes propriedades físicas dos dentes artificiais é a resistência ao desgaste e a capacidade de manter estável a relação oclusal do paciente. Para avaliar o grau de desgaste de oito diferentes marcas de dentes artficiais de resina disponíveis comercialmente, foram preparados 48 corpos-de-prova de oito marcas disponíveis no mercado, totalizando oito grupos com seis elementos cada. As amostras foram avaliadas através do método gravimétrico, analisadas segundo a diferença dos pesos inicial e final após o ensaio dos corpos-de-prova. Os valores obtidos foram submetidos à análise de variância e teste de Tukey (p<0,05). A análise estatística revelou diferença entre os dentes das marcas Artplus, Biolux, Duratone, Trilux, Trubyte Biotone e Vipi Dent Plus e os dentes SR Orthosit. Os dentes da marca Myerson não apresentaram diferença estatistica-mente significante com nenhuma das outras marcas testadas (p<0,05). Os dentes das marcas Artplus, Biolux, Duratone, Trilux, Trubyte Biotone e Vipi Dent Plus apresentaram os maiores valores de desgaste, enquanto que os dentes da marca Ivoclar apresentaram os menores valores. Os dentes Myerson apresentaram resultados com valores intermediários.
Asunto(s)
Ciencia de los Materiales , Abrasión de los Dientes , Diente Artificial , Análisis de VarianzaRESUMEN
Não existe consenso quanto às relações oclusais excêntricas para próteses totais,pois os benefícios da oclusão balanceada permanecem desconhecidos. O objetivo deste estudo foi determinar a influência da desoclusão pelo canino sobre os movimentos da prótese total maxilar durante a mastigação. A amostra foi formada por 15 portadores de próteses totais bimaxilares (10 mulheres, 5 homens) e analisada durante a mastigação de alimento-teste (pedaço de pão tipo forma) por 20 segundos. A movimentação das próteses foi mensurada por um cinesiógrafomandibular (K6-I Diagnostic System, Myotronics Research Inc, Seattle, WA) capaz de detectar movimentos de um magneto aderido à prótese. Realizou-se o procedimento inicialmente comoclusão balanceada bilateral (A), imediatamente após conferir desoclusão pelo canino (B) e com 15 dias de desoclusão pelo canino (C). Os resultados foram comparados por meio do teste de Friedman (α = 0,05). Os valores médios (em mm; ± desvio padrão) foram: A: 0,60 ± 0,39(eixo vertical), 0,57 ± 0,34 (eixo ântero-posterior) e 0,24 ± 0,41 (eixo lateral); B: 0,63 ± 0,44 (eixo vertical), 0,69 ± 0,54 (eixo antero-posterior) e 0,01 ± 0,34 (eixo lateral); C: 0,61 ± 0,45 (eixo vertical), 0,58 ± 0,49 (eixo antero-posterior) e 0,04 ± 0,39 (eixo lateral). A análise dos eixos vertical e ântero-posterior não demonstrou diferenças significantes (P < 0,89 e P < 0,19, respectivamente). Houve diferença somente para o eixo lateral (P < 0,02), e apenas A e C foramdiferentes. Este estudo sugere que a oclusão excursiva influencia o movimento da prótese total maxilar durante a mastigação. O efeito da desoclusão pelo canino foi uma redução no movimento da prótese após 15 dias.
Asunto(s)
Masticación , Oclusión Dental Balanceada , Dentadura CompletaRESUMEN
O conhecimento das estruturas anatômicas da cavidade oral é fundamental para realização do tratamento protético, bem como das alterações ocorridas nos tecidos ósseo, gengival, muscular e nas articulações têmporo-mandibulares (ATM) com a perda dos dentes. Tais modificações afetam a mastigação, fonação, estética e conforto do paciente. Alterações como reabsorção óssea, hipotonicidade muscular e disfunções da ATM podem ser amenizados com um tratamento reabilitador protético adequado. O entendimento destes processos propicia a realização de uma reabilitação consciente, suprindo as necessidades e expectativas do paciente e proporcionando satisfação ao dentista. Assim, na confecção dessa prótese deve-se respeitar os limites anatômicos e fisiológicos da atuação da musculatura envolvida, analisar a área de rebordo residual, definindo corretamente a área chapeavel, diagnosticar a presença de bridas e torus e no assoalho bucal deve-se respeitar o freio lingual, as inserções dos músculos genioglosso e o fórnix gengival. Conhecer e respeitar as estruturas anatômicas é essencial para a obtenção de sucesso no tratamento de indivíduos desdentados totais
The knowledge of the mouth anatomic structure and the alterations ocurred after teeth lost, are very important for good results in complete denture. After the lost of teeth changes in bone, gingival and muscle tissue and temporomandibular articulations affecting directly in mastication, speaking, esthetic and patient confort. Alterations like bone resorption, muscle hipotonicity and temporomandibular disorders can be minimized with an adequate prosthetic rehabilitation treatment. The understanding of these process leads to a conscious prosthetic rehabilitation, suppling the needs and expectations of the patient and providing satisfaction to dentist. So, in the fabrication of complete denture the anatomic limit and the post damming should be respect; the residual bone area should be analysed; the presence of lingual frenun, torus, insertion of genioglosso muscle and lingualgingival fornix should be diagnosed. Knowing and respecting the mouth anatomic structures is essencial to achieve success in prosthesis treatment of edentulous patient