Talanta ; 55(2): 249-54, 2001 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-18968367

RESUMEN

The PB film-modified electrode was used as an amperometric detector for flow injection analysis of ascorbic acid. The modified electrode detector showed good sensitivity, stability and reproducibility. The calibration curve for ascorbic acid was linear over the concentration range from 5.0x10(-6) to 1.0x10(-3) mol l(-1) with a slope of 19.9 mA mol(-1) per litre and a correlation coefficient of 0.999. The detection limit of this method was 2.49x10(-6) mol l(-1). The relative standard deviation of six replicate injections of 2.5x10(-4) mol l(-1) ascorbic acid was 2.5%. The results obtained for ascorbic acid determination in pharmaceutical products are in good agreement with those obtained by using the procedure involving the reaction between triiodide and ascorbic acid.

3.
Talanta ; 49(2): 271-5, 1999 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-18967597

RESUMEN

Electroactive nickel(II) hexacyanoferrate (NiHCF) thin film modified electrodes are effective potentiometric sensors for the determination of potassium ions. The NiHCF films are deposited onto glassy carbon electrodes by repetitive potential cycling in K(3)Fe(CN)(6)/NaNO(3)/Ni(NO(3))(2) solution. The modified electrodes exhibit a linear response to potassium ions in the concentration range 1x10(-3) to 2.0 mol dm(-3), with a near-Nernstian slope (45-49 mV per decade) at 25 degrees C. In the determination of potassium ion in syrups used for treatment of potassium deficiency, the NiHCF-modified electrode gave comparable results to those obtained using flame emission spectrophotometry.

4.
Talanta ; 44(2): 185-8, 1997 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18966733

RESUMEN

The determination of traces of Zn, Pb and Cu in rum samples by anodic stripping voltammetry without previous treatment or addition of a supporting electrolyte, using a hanging mercury drop electrode, is described. The choice of an appropriate stripping voltammetric method and deposition potential minimizes the influence of the organic content and ensures good reproductibility of the measurements. The reliability of the method was tested by comparing the results with those given by absorption spectrometry, the differences being about 10%. The method allows heavy metal ions to be determined in the mug l(-1) concentration range.