Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 34(7): 1039-49, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17287961

RESUMEN

PURPOSE: A procedure for the measurement of spatial dose rate distribution of beta particles emitted by 186Re-liposomes in tumoral tissue, using HS GafChromic films, is presented. METHODS: HNSCC xenografts were intratumorally injected with 3.7 or 11.1 MBq of 186Re-liposomes, and planar gamma camera images were acquired to determine the liposome retention in the tumor. After imaging, rats were sacrificed and tumors were excised and processed in slices; HS film sections were placed between slices and the tumor lobe was reassembled. Tumors and films were kept in the dark at 4 degrees C for 18 h. After irradiation, films were removed and response was read using a transmission scanner. Films were analyzed to determine two-dimensional spatial dose rate distributions and cumulative dose volume histograms. Dose rate distributions were quantified using a 60Co calibration curve, the 186Re physical half-life, and a perturbation factor that takes into account the effect of the film protective layer. RESULTS: Dose rate distributions are highly heterogeneous with maximal dose rates about 0.4 Gy h(-1) in tumors injected with 3.7 MBq and 1.3 Gy h(-1) in tumors injected with 11.1 MBq. Dose volume histograms showed dose distributed in more than 95% and 80% of the tumor when injected with the lower and the higher activity, respectively. CONCLUSION: The described procedures and techniques have shown the potential and utility of HS GafChromic film for determination of dose rate distributions in solid tumors injected intratumorally with 186Re-liposomes. The film's structure and the liposomes' biodistribution must be taken into account to obtain quantitative dose measurements.


Asunto(s)
Carcinoma de Células Escamosas/metabolismo , Dosimetría por Película/métodos , Liposomas/química , Radioisótopos/farmacocinética , Radiofármacos/administración & dosificación , Renio/administración & dosificación , Renio/farmacocinética , Animales , Carcinoma de Células Escamosas/radioterapia , Portadores de Fármacos/química , Humanos , Masculino , Radioisótopos/administración & dosificación , Radiofármacos/farmacocinética , Dosificación Radioterapéutica , Ratas , Ratas Desnudas , Efectividad Biológica Relativa , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA