Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 25(6): e14379, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38700940

RESUMEN

PURPOSE: A novel pulse normalization technology enabling the acquisition of low noise beam data without the use of a physical reference chamber has recently been commercially released. The purpose of this study was to characterize the use of this technology for beam scanning of small fields required in the commissioning of a stereotactic radiotherapy program. METHODS: Three detectors (Edge diode, microDiamond, PinPoint) were used to acquire beam data under three conditions: with a reference chamber, with pulse normalization and no reference chamber (PN), and without pulse normalization and no reference chamber (nPN). Percent depth dose (PDD) scans were acquired for 0.5, 1.0, 2.0, and 3.0 cm2 field sizes and profiles were acquired at 1.4, 10, and 30 cm depths using continuous scanning. The coefficient of variation (CoV) was calculated for all beam data to compare signal-to-noise and gamma comparisons (1%, 1 mm) were calculated of the PN and nPN scans compared to the reference data. RESULTS: Average 95th percentile CoV values were similar for all detectors across conditions, with PN data being comparable to reference data and minor increases observed for nPN data. Mean gamma pass rates for PN PDD scans exceeded 98% for all detectors. Profile gamma pass rates were 100% for all detectors at 1.4 and 10 cm depth. At 30 cm depth, profiles acquired with the PinPoint and microDiamond detectors had lower mean gamma pass rates than the Edge, at 95% and 95.7%, respectively. CONCLUSIONS: A novel pulse normalization technology was demonstrated to be effective for acquiring beam profiles and PDDs for small fields without the use of a physical reference chamber. Limitations in how the method is implemented led to some errors in data acquired using lower sensitivity detectors. When used with a diode, pulse normalization produced equivalent scans to those acquired with a reference chamber.


Asunto(s)
Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Fantasmas de Imagen , Radiometría/métodos , Radiometría/instrumentación , Aceleradores de Partículas/instrumentación , Radioterapia de Intensidad Modulada/métodos , Relación Señal-Ruido
2.
J Appl Clin Med Phys ; 24(12): e14206, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37962024

RESUMEN

PURPOSE: To present the commissioning process of a low-cost solution for directly 3D printed flexible patient specific bolus. METHODS: The 3D printing solution used in this study consisted of a resin stereolithography 3D printer and a flexible curing resin. To test the dimensional accuracy of the 3D printer, rectangular cuboids with varying dimensions were 3D printed and their measured dimensions were compared to the designed dimensions. Percent Depth Dose (PDD) profiles were measured by irradiating film embedded in a 3D printed phantom made of the flexible material. A CT of the phantom was acquired and used to replicate the irradiation setup in the treatment planning system. PDDs were calculated for both the native HU of the phantom, and with the phantom HU overridden to 300 HU to match its physical density. Dosimetric agreement was characterized by comparing calculated to measured depths of R90, R80, and R50. Upon completion of the commissioning process, a bolus was 3D printed for a clinical case study for treatment of the nose. RESULTS: Dimensional accuracy of the printer and material combination was found to be good, with all measured dimensions of test cuboids within 0.5 mm of designed. PDD measurements demonstrated the best dosimetric agreement when the material was overridden to 300 HU, corresponding to the measured physical density of the material of 1.18 g/cc. Calculated and measured depths of R90, R80, and R50 all agreed within 1 mm. The bolus printed for the clinical case was free from defects, highly conformal, and led to a clinically acceptable plan. CONCLUSION: The results of the commissioning measurements performed indicate that the 3D printer and material solution are suitable for clinical use. The 3D printer and material combination can provide a low-cost solution a clinic can implement in-house to directly 3D print flexible bolus.


Asunto(s)
Nariz , Radiometría , Humanos , Dosificación Radioterapéutica , Fantasmas de Imagen , Impresión Tridimensional
3.
J Appl Clin Med Phys ; 24(3): e13858, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36583305

RESUMEN

PURPOSE: Patient Specific QA (PSQA) by direct phantom measurement for all intensity modulated radiation therapy (IMRT) cases is labor intensive and an inefficient use of the Medical Physicist's time. The purpose of this work was to develop a hybrid quality assurance (QA) technique utilizing 3D dose verification as a screening tool to determine if a measurement is necessary. METHODS: This study utilized Sun Nuclear DoseCHECK (DC), a 3D secondary verification software, and Fraction 0, a trajectory log IMRT QA software. Twenty-two Lung stereotactic body radiation therapy (SBRT) and thirty single isocentre multi-lesion SRS (MLSRS) plans were retrospectively analysed in DC. Agreement of DC and the TPS dose for selected dosimetric criteria was recorded. Calculated 95% confidence limits (CL) were used to establish action limits. All cases were delivered and measured using the Sun Nuclear stereotactic radiosurgery (SRS) MapCheck. Trajectory logs of the delivery were used to calculate Fraction 0 results for the same criteria calculated by DC. Correlation of DC and Fraction 0 results were calculated. Phantom measured QA was compared to Fraction 0 QA results for the cases which had DC criteria action limits exceeded. RESULTS: Correlation of DC and Fraction 0 results were excellent, demonstrating the same action limits could be used for both and DC can predict Fraction 0 results. Based on the calculated action limits, zero lung SBRT cases and six MLSRS cases were identified as requiring a measurement. All plans that passed the DC screening had a passing measurement based PSQA and agreed with Fraction 0 results. CONCLUSION: Using 95% CL action limits of dosimetric criteria, a 3D secondary dose verification can be used to determine if a measurement is required for PSQA. This method is efficient for it is part of the normal clinical workflow when verifying any clinical treatment. In addition, it can drastically reduce the number of measurements needed for PSQA.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Estudios Retrospectivos , Garantía de la Calidad de Atención de Salud , Radiometría/métodos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos
4.
J Appl Clin Med Phys ; 22(11): 64-70, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34609063

RESUMEN

There are several methods available in the literature for predicting the insert factor for clinical electron beams. The purpose of this work was to build on a previously published technique that uses a bivariate spline model generated from elliptically parameterized empirical measurements. The technique has been previously validated for Elekta linear accelerators for limited clinical electron setups. The same model is applied to Varian machines to test its efficacy for use with these linear accelerators. Insert factors for specifically designed elliptical cutouts were measured to create spline models for 6, 9, 12, 16, and 20 MeV electron energies for four different cone sizes at source-to-surface distances (SSD) of 100, 105, and 110 cm. Insert factor validation measurements of patient cutouts and clinical standard cutouts were acquired to compare to model predictions. Agreement between predicted insert factors and validation measurements averaged 0.8% over all energies, cones, and clinical SSDs, with an uncertainty of 0.6% (1SD), and maximum deviation of 2.1%. The model demonstrated accurate predictions of insert factors using the minimum required amount of input data for small cones, with more input measurements required for larger cones. The results of this study provide expanded validation of this technique to predict insert factors for all energies, cones, and SSDs that would be used in most clinical situations. This level of accuracy and the ease of creating the model necessary for the insert factor predictions demonstrate its acceptability to use clinically for Varian machines.


Asunto(s)
Electrones , Planificación de la Radioterapia Asistida por Computador , Humanos , Método de Montecarlo , Aceleradores de Partículas , Dosificación Radioterapéutica
5.
J Appl Clin Med Phys ; 21(9): 6-15, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32603542

RESUMEN

PURPOSE: Frameless Gamma Knife stereotactic radiosurgery (SRS) uses a moldable headrest with a thermoplastic mask for patient immobilization. An efficacious headrest is time consuming and difficult to fabricate due to the expertise required to mold the headrest within machine geometrical limitations. The purpose of this study was to design and validate a three-dimensional (3D)-printed headrest for frameless Gamma Knife SRS that can overcome these difficulties. MATERIALS AND METHODS: A headrest 3D model designed to fit within the frameless adapter was 3D printed. Dosimetric properties of the 3D-printed headrest and a standard-of-care moldable headrest were compared by delivering a Gamma Knife treatment to an anthropomorphic head phantom fitted with an ionization chamber and radiochromic film. Ionization measurements were compared to assess headrest attenuation and a gamma index was calculated to compare the film dose distributions. A volunteer study was conducted to assess the immobilization efficacy of the 3D-printed headrest compared to the moldable headrest. Five volunteers had their head motion tracked by a surface tracking system while immobilized in each headrest for 20 min. The recorded motion data were used to calculate the average volunteer movement and a paired t-test was performed. RESULTS: The ionization chamber readings were within 0.55% for the 3D-printed and moldable headrests, and the calculated gamma index showed 98.6% of points within dose difference of 2% and 2 mm distance to agreement for the film measurement. These results demonstrate that the headrests were dosimetrically equivalent within the experimental uncertainties. Average motion (±standard deviation) of the volunteers while immobilized was 1.41 ± 0.43 mm and 1.36 ± 0.51 mm for the 3D-printed and moldable headrests, respectively. The average observed volunteer motion between headrests was not statistically different, based on a P-value of 0.466. CONCLUSIONS: We designed and validated a 3D-printed headrest for immobilizing patients undergoing frameless Gamma Knife SRS.


Asunto(s)
Radiocirugia , Cabeza , Humanos , Fantasmas de Imagen , Impresión Tridimensional , Radiometría
6.
J Appl Clin Med Phys ; 20(3): 89-96, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30821903

RESUMEN

PURPOSE: The goal of total scalp irradiation (TSI) is to deliver a uniform dose to the scalp, which requires the use of a bolus cap. Most current methods for fabricating bolus caps are laborious, yet still result in nonconformity and low reproducibility, which can lead to nonuniform irradiation of the scalp. We developed and validated patient-specific bolus caps for TSI using three-dimensional (3D) printing. METHODS AND MATERIALS: 3D-printing materials were radiologically analyzed to identify a material with properties suitable for use as a bolus cap. A Python script was developed within a commercial treatment planning system to automate the creation of a ready-to-print, patient-specific 3D bolus cap model. A bolus cap was printed for an anthropomorphic head phantom using a commercial vendor and a computed tomography simulation of the anthropomorphic head phantom and bolus cap was used to create a volumetric-modulated arc therapy TSI treatment plan. The planned treatment was delivered to the head phantom and dosimetric validation was performed using thermoluminescent dosimeters (TLD). The developed procedure was used to create a bolus cap for a clinical TSI patient, and in vivo TLD measurements were acquired for several fractions. RESULTS: Agilus-60 was validated as a new 3D-printing material suitable for use as bolus. A 3D-printed Agilus-60 bolus cap had excellent conformality to the phantom scalp, with a maximum air gap of 4 mm. TLD measurements showed that the bolus cap generated a uniform dose to the scalp within a 2.7% standard deviation, and the delivered doses agreed with calculated doses to within 2.4% on average. The patient bolus was conformal and the average difference between TLD measured and planned doses was 5.3%. CONCLUSIONS: We have developed a workflow to 3D-print highly conformal bolus caps for TSI and demonstrated these caps can reproducibly generate a uniform dose to the scalp.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Fantasmas de Imagen , Impresión Tridimensional/instrumentación , Cuero Cabelludo/efectos de la radiación , Neoplasias Cutáneas/radioterapia , Anciano , Humanos , Masculino , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada
7.
J Vis Exp ; (134)2018 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-29708544

RESUMEN

The Radiation Planning Assistant (RPA) is a system developed for the fully automated creation of radiotherapy treatment plans, including volume-modulated arc therapy (VMAT) plans for patients with head/neck cancer and 4-field box plans for patients with cervical cancer. It is a combination of specially developed in-house software that uses an application programming interface to communicate with a commercial radiotherapy treatment planning system. It also interfaces with a commercial secondary dose verification software. The necessary inputs to the system are a Treatment Plan Order, approved by the radiation oncologist, and a simulation computed tomography (CT) image, approved by the radiographer. The RPA then generates a complete radiotherapy treatment plan. For the cervical cancer treatment plans, no additional user intervention is necessary until the plan is complete. For head/neck treatment plans, after the normal tissue and some of the target structures are automatically delineated on the CT image, the radiation oncologist must review the contours, making edits if necessary. They also delineate the gross tumor volume. The RPA then completes the treatment planning process, creating a VMAT plan. Finally, the completed plan must be reviewed by qualified clinical staff.


Asunto(s)
Dosificación Radioterapéutica/normas , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Humanos
8.
Phys Imaging Radiat Oncol ; 8: 38-43, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33458415

RESUMEN

BACKGROUND AND PURPOSE: Postmastectomy radiotherapy (PMRT) is complex to plan and deliver, but could be improved with 3D-printed, patient-specific electron tissue compensators. The purposes of this study were to develop an algorithm to design patient-specific compensators that achieve clinical goals, to 3D-print the planned compensators, and validate calculated dose distributions with film and thermoluminescent dosimeter (TLD) measurements in 3D-printed phantoms of PMRT patients. MATERIALS AND METHODS: An iterative algorithm was developed to design compensators corresponding to single-field, single-energy electron plans for PMRT patients. The 3D-printable compensators were designed to fit into the electron aperture, with cerrobend poured around it. For a sample of eight patients, calculated dose distributions for compensator plans were compared with patients' (multi-field, multi-energy) clinical treatment plans. For all patients, dosimetric parameters were compared including clinical target volume (CTV), lung, and heart metrics. For validation, compensators were fabricated and irradiated for a set of six 3D-printed patient-specific phantoms. Dose distributions in the phantoms were measured with TLD and film. These measurements were compared with the treatment planning system calculated dose distributions. RESULTS: The compensator treatment plans achieved superior CTV coverage (97% vs 89% of the CTV receiving the prescription dose, p < 0.0025), and similar heart and lung doses (p > 0.35) to the conventional treatment plans. Average differences between calculated and measured TLD values were 2%, and average film profile differences were <2 mm. CONCLUSIONS: We developed a new compensator based treatment methodology for PMRT and demonstrated its validity and superiority to conventional multi-field plans through end-to-end testing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA