1.
Phys Med ; 124: 103431, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39059250

RESUMEN

PURPOSE: The objective of our IAEA-coordinated international study was to assess CT practices and radiation doses from multiple hospitals across several African countries. METHODS: The study included 13 hospitals from Africa which contributed information on minimum of 20 consecutive patients who underwent head, chest, and/or abdomen-pelvis CT. Prior to the data recording step, all hospitals had a mandatory one-hour training on the best practices in recording the relevant data elements. The recorded data elements included patient age, weight, protocol name, scanner information, acquisition parameters, and radiation dose descriptors including phase-specific CT dose index volume (CTDIvol in mGy) and dose length product (DLP in mGy.cm). We estimated the median and interquartile range of body-region specific CTDIvol and DLP and compared data across sites and countries using the Kruskal-Wallis H Test for non-normal distribution, analysis of variance. RESULTS: A total of 1061 patients (mean age 50 ± 19 years) were included in the study. 16 % of CT exams had no stated clinical indications for CT examinations of the head (32/343, 9 %), chest (50/281, 18 %), abdomen-pelvis (67/243, 28 %), and/or chest-abdomen-pelvis CT (24/194, 12 %). Most hospitals used multiphase CT protocols for abdomen-pelvis (9/11 hospitals) and chest CT (10/12 hospitals), regardless of clinical indications. Total median DLP values for head (953 mGy.cm), chest (405 mGy.cm), and abdomen-pelvis (1195 mGy.cm) CT were above the UK, German, and American College of Radiology Diagnostic Reference Levels (DRLs). CONCLUSIONS: Concerning variations in CT practices and protocols across several hospitals in Africa were demonstrated, emphasizing the need for better protocol optimization to improve patient safety.


Asunto(s)
Agencias Internacionales , Dosis de Radiación , Tomografía Computarizada por Rayos X , Humanos , África , Persona de Mediana Edad , Masculino , Femenino , Adulto , Energía Nuclear , Anciano
2.
Phys Med ; 68: 146-154, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31786482

RESUMEN

PURPOSE: The aim of this multicenter study was to evaluate the performance of the upgraded version of the Ingenuity TF PET/CT scanner, according to the NEMA NU-2 2012 standards. METHODS: Spatial resolution, sensitivity, count rate response, scatter fraction, image quality and accuracy were evaluated on three Ingenuity TF scanners installed in Italian hospitals. Furthermore, energy and timing resolution were measured. A detailed image quality phantom analysis was performed to evaluate the effect of different clinical reconstruction parameters, including the application of PSF correction. RESULTS: Results show an average spatial resolution of 4.7 mm and an average absolute system sensitivity of 7.9 cps/kBq. The average maximum NECR was 119.83 kcps at 20.67 kBq/ml, while the maximum true event rate was 322.62 kcps at the concentration of 24.51 kBq/ml. The average maximum bias below NECR peak was 12.58%. All the results of NEMA tests were in agreement with the values declared by the manufacturer. The estimated average energy and timing resolution were 10.83% and 536.2 ps, respectively. Image quality phantom analysis obtained with different reconstruction settings showed that PSF correction was the parameter that affected mainly on contrast recovery coefficient, while the iteration number and amplitude of Gaussian filter had no significant effect. Of relevance, the application of PSF correction never led to recovery coefficient values higher than 100% and to Gibbs or edge artifacts. CONCLUSIONS: The new Ingenuity TF model shows physical performance similar to other scanners of the latest generation for all standard NEMA NU2-2012 measurements.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones/instrumentación , Humanos , Procesamiento de Imagen Asistido por Computador , Control de Calidad , Factores de Tiempo