Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Prosthodont ; 27(5): 421-428, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29143397

RESUMEN

PURPOSE: To evaluate the marginal fit of CAD/CAM copings milled from hybrid ceramic (Vita Enamic) blocks and lithium disilicate (IPS e.max CAD) blocks, and to evaluate the effect of crystallization firing on the marginal fit of lithium disilicate copings. MATERIALS AND METHODS: A standardized metal die with a 1-mm-wide shoulder finish line was imaged using the CEREC AC Bluecam. The coping was designed using CEREC 3 software. The design was used to fabricate 15 lithium disilicate and 15 hybrid ceramic copings. Design and milling were accomplished by one operator. The copings were seated on the metal die using a pressure clamp with a uniform pressure of 5.5 lbs. A Macroview Microscope (14×) was used for direct viewing of the marginal gap. Four areas were imaged on each coping (buccal, distal, lingual, mesial). Image analysis software was used to measure the marginal gaps in µm at 15 randomly selected points on each of the four surfaces. A total of 60 measurements were made per specimen. For lithium disilicate copings the measurements for marginal gap were made before and after crystallization firing. Data were analyzed using paired t-test and Kruskal-Wallis test. RESULTS: The overall mean difference in marginal gap between the hybrid ceramic and crystallized lithium disilicate copings was statistically significant (p < 0.01). Greater mean marginal gaps were measured for crystallized lithium disilicate copings. The overall mean difference in marginal gap before and after firing (precrystallized and crystallized lithium disilicate copings) showed an average of 62 µm increase in marginal gap after firing. This difference was also significant (p < 0.01). CONCLUSIONS: A significant difference exists in the marginal gap discrepancy when comparing hybrid ceramic and lithium disilicate CAD/CAM crowns. Also crystallization firing can result in a significant increase in the marginal gap of lithium disilicate CAD/CAM crowns.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Adaptación Marginal Dental , Diseño de Prótesis Dental , Cerámica/química , Cristalización , Técnica de Colado Dental , Técnica de Impresión Dental , Porcelana Dental/química , Humanos , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA