Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
EuroIntervention ; 20(18): e1173-e1183, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39279514

RESUMEN

BACKGROUND: The 12-month outcomes of BIOMAG-I - the first-in-human study investigating the third-generation drug-eluting resorbable magnesium scaffold (DREAMS 3G) - showed promising results regarding clinical outcomes and late lumen loss. AIMS: The current study aimed to investigate vascular healing parameters assessed by optical coherence tomography (OCT) and intravascular ultrasound (IVUS), focusing on strut visibility, vessel and scaffold areas, and neointimal growth patterns. METHODS: This is a BIOMAG-I substudy including patients with available serial OCT and IVUS data. We conducted a frame-based analysis of OCT findings in conjunction with IVUS-derived vessel and scaffold areas, evaluating the qualitative and quantitative aspects of vascular healing. RESULTS: Among the 116 patients enrolled in this trial, 56 patients treated with DREAMS 3G were included in the analysis. At 12 months, OCT imaging revealed that 99.0% of the struts were invisible, and no malapposed struts were depicted. While the vessel area showed no significant difference between the timepoints, the minimum lumen area significantly decreased from post-percutaneous coronary intervention to 6 months (6.88 mm2 to 4.75 mm2; p<0.0001), but no significant changes were observed between 6 and 12 months. Protruding neointimal tissue (PNT) - a unique neointimal presentation observed following resorbable magnesium scaffold implantation - was observed in 89.3% of the study patients at 12 months, and its area exhibited a 47.4% decrease from 6 to 12 months. CONCLUSIONS: This imaging substudy revealed that, at 12-month follow-up, virtually all struts of the DREAMS 3G scaffold became invisible, without evident malapposition. The vascular healing response to DREAMS 3G implantation also appeared favourable up to 12 months, which is indicated by advanced strut degradation and spontaneous regressing PNT between 6 and 12 months.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Stents Liberadores de Fármacos , Magnesio , Intervención Coronaria Percutánea , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Humanos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Persona de Mediana Edad , Ultrasonografía Intervencional/métodos , Anciano , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/instrumentación , Vasos Coronarios/diagnóstico por imagen , Resultado del Tratamiento , Neointima , Andamios del Tejido
2.
Clin Res Cardiol ; 113(7): 1060-1069, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38740722

RESUMEN

BACKGROUND: The ISAR-REACT 5 trial compared the efficacy and safety of ticagrelor and prasugrel in patients with ACS managed invasively. The present study sought to investigate the impact of ticagrelor and prasugrel on the incidence and pattern of urgent revascularization in acute coronary syndromes (ACS) patients undergoing percutaneous coronary intervention (PCI). METHODS AND RESULTS: This post-hoc analysis of the ISAR-REACT 5 trial included all ACS patients who underwent PCI. The primary endpoint for this analysis was the incidence of urgent revascularization at 12-month follow-up. Secondary outcome was the pattern of urgent revascularization procedures (namely, urgent target vessel/non-target vessel revascularization - TVR/NTVR). Among 3,377 ACS patients who underwent PCI, 1,676 were assigned to ticagrelor and 1,701 to prasugrel before PCI. After 12 months, the incidence of urgent revascularization was higher among patients assigned to ticagrelor as compared to prasugrel (6.8% vs. 5.2%; hazard ratio [HR] = 1.32, 95% confidence interval [CI] 1.00-1.75; p = 0.051), mostly attributable to significantly more urgent NTVR in the ticagrelor group (3.8% vs. 2.4%; HR = 1.62 [1.09-2.41]; p = 0.017). The risk of urgent TVR did not differ between treatment groups (3.3% vs. 3.0%; HR = 1.13 [0.77-1.65]; p = 0.546). CONCLUSIONS: In ACS patients treated with PCI, the cumulative rate of urgent revascularizations after 12 months is higher with ticagrelor compared to prasugrel, due to a significant increase in urgent revascularizations involving remote coronary vessels.


Asunto(s)
Síndrome Coronario Agudo , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria , Clorhidrato de Prasugrel , Ticagrelor , Humanos , Ticagrelor/uso terapéutico , Clorhidrato de Prasugrel/uso terapéutico , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/cirugía , Masculino , Femenino , Intervención Coronaria Percutánea/métodos , Persona de Mediana Edad , Incidencia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Resultado del Tratamiento , Anciano , Estudios de Seguimiento , Factores de Tiempo
3.
Clin Res Cardiol ; 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37930402

RESUMEN

BACKGROUND: The performance of modified balloons (namely cutting or scoring balloons) to prepare severely calcified lesions in patients undergoing percutaneous coronary intervention (PCI) remains controversial. We investigated the clinical and imaging outcomes of patients undergoing PCI assigned to modified balloon therapy to prepare severely calcified coronary lesions before stent implantation. METHODS: In this meta-analysis, we aggregated the study-level data from trials enrolling invasively treated patients who were randomly assigned to modified balloon or control therapy to prepare severely calcified lesions before stenting. The primary outcome was major adverse cardiac events (MACE), including death, myocardial infarction (MI), and repeat revascularization. The secondary outcomes included the individual components of the primary outcome, coronary perforation and final minimal stent area (MSA) as measured by intracoronary imaging. RESULTS: A total of 648 participants in six trials were allocated to modified balloon therapy (n = 335) or control therapy (semi-compliant, non-compliant, or super high-pressure balloon, n = 313). The median follow-up was 11 months. Overall, MACE occurred in 8.96% of patients assigned to a modified balloon and 12.78% of patients assigned to control therapy [risk ratio = 0.70, 95% confidence interval (CI) 0.35-1.39; P = 0.24]. There was a significant treatment effect-by-modified balloon type interaction for the outcome MACE in patients assigned to cutting balloon compared with control therapy [RR = 0.40 (0.28-0.56), P for interaction (Pint) < 0.001]. Patients treated with a modified balloon compared with control therapy showed neither a significant difference for the other clinical outcomes nor for final MSA [standardized mean difference = 0.67 (- 0.71, 2.06); P = 0.26]. CONCLUSIONS: In patients treated with PCI for severely calcific coronary artery disease a strategy of lesion preparation with a modified balloon before stenting does not improve clinical or imaging outcomes compared with control therapy. The different performance of cutting and scoring balloons warrants further investigation.

4.
Am Heart J ; 264: 114-122, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37315878

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) was established as a standard treatment for high-operative risk patients with severe aortic stenosis (AS). Although coronary artery disease (CAD) often coexists with AS, clinical and angiographic evaluations of stenosis severity are unreliable in this specific setting. To provide precise risk stratification of coronary lesions, combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) was developed to integrate morphological and molecular information on plaque composition. However, there is a lack of evidence on the association between NIRS-IVUS derived findings such as maximum 4mm lipid core burden index (maxLCBI4mm) and clinical outcomes in AS patients undergoing TAVI. This registry aims to assess feasibility and safety of NIRS-IVUS imaging in the setting of routine pre-TAVI coronary angiography to improve assessment of CAD severity. METHODS: The registry is designed as a non-randomized, prospective, observational, multicenter cohort registry. Patients referred for TAVI with angiographic evidence of CAD receive NIRS-IVUS imaging and are followed up to 24 months. Enrolled patients are classified as NIRS-IVUS positive and NIRS-IVUS negative, respectively, based on their maxLCBI4mm to compare their clinical outcomes. The primary endpoint of the registry is major adverse cardiovascular events over a 24-month follow-up period. CONCLUSIONS: Identification of patients likely or unlikely to benefit from revascularization prior to TAVI represents an important unmet clinical need. This registry is designed to investigate whether NIRS-IVUS-derived atherosclerotic plaque characteristics can identify patients and lesions at risk for future adverse cardiovascular events after TAVI, in order to refine interventional decision-making in this challenging patient population.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Espectroscopía Infrarroja Corta/métodos , Estudios Prospectivos , Ultrasonografía Intervencional/métodos , Angiografía Coronaria , Sistema de Registros
5.
J Clin Med ; 12(9)2023 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-37176615

RESUMEN

BACKGROUND: The aspartate aminotransferase (AST) to alanine aminotransferase (ALT) ratio (De Ritis ratio), obtained from AST and ALT activities in the healthy range, has not been studied in association with mortality. METHODS: This study included 3392 patients with stable coronary heart disease and aminotransferase activity in the reference range. Patients are categorized into two groups: a group with AST and ALT activity in the healthy range (n = 1697), and a group with AST and/or ALT activity outside the healthy range but in the reference range (n = 1695). The primary endpoint was all-cause mortality at three years. RESULTS: The De Ritis ratio (median 5th-95th percentile] was 0.94 [0.61-1.41] in patients with AST and ALT in the healthy range and 0.93 [0.45-1.96] in patients with AST and/or ALT outside the healthy range (p = 0.700). At three years, there were 86 deaths in patients with AST and ALT in the healthy range: 27 deaths (3.9%) in patients with a De Ritis ratio ≤median, and 59 deaths (8.2%) in patients with the De Ritis ratio >median (adjusted hazard ratio [HR] = 1.16, 95% confidence interval [CI] 0.94 to 1.42; p = 0.159); in patients with AST and/or ALT outside the healthy range, there were 148 deaths: 49 deaths (6.6%) in patients with a De Ritis ratio ≤median, and 99 deaths (14.1%) in patients with De Ritis ratio >median (adjusted HR = 1.27 [1.09-1.48], p = 0.002), with both HRs calculated per unit higher values of the De Ritis ratio. CONCLUSIONS: The De Ritis ratio obtained from AST and ALT activity in the healthy range was not independently associated with higher risk of mortality. The De Ritis ratio obtained from aminotransferase activity outside the healthy range (but still in the reference range) was independently associated with the risk of mortality.

7.
EuroIntervention ; 18(16): e1328-e1338, 2023 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-36785947

RESUMEN

BACKGROUND: The treatment of drug-eluting stent (DES) in-stent restenosis (ISR) is challenging as it has a high risk of recurrence. AIMS: The aim of this analysis was to develop and validate a model to predict the risk of repeat percutaneous coronary intervention (PCI) for recurrent DES-ISR. METHODS: A retrospective, observational analysis was performed including consecutive patients treated with PCI for DES-ISR at two centres in Germany. Included patients were randomly divided into training and validation cohorts. Two regression analyses identified factors associated with repeat PCI for recurrent DES-ISR up to 1 year. The discriminative ability of the resultant model was then compared to a benchmark ISR classification model using bootstrap resampling. A classification and regression tree analysis and a numerical scoring system (the ISAR score) were used to predict the risk of repeat PCI for recurrent DES-ISR based on the identified predictors. RESULTS: We included 1,986 patients in the current analysis, divided randomly into training (1,471 patients, 1,778 lesions) and validation (515 patients, 614 lesions) cohorts. Four factor variables (a non-focal ISR pattern, a time interval to ISR of <6 months, ISR of the left circumflex artery and ISR in a calcified vessel) were associated with repeat PCI for recurrent DES-ISR at 1-year follow-up. On bootstrap resampling analysis, the C-statistic for the model including these four variables was 0.60 (95% confidence interval [CI]: 0.57-0.63), whereas the C-statistic for the benchmark ISR classification model was 0.54 (95% CI: 0.52-0.57), a difference that was statistically significant (delta C-statistic 0.062; 95% CI: 0.035-0.094; p<0.001). The cumulative incidence of repeat PCI for recurrent DES-ISR was over three times higher in DES-ISR lesions with an ISAR score of ≥3 in comparison to lesions with an ISAR score of 0. CONCLUSIONS: This study developed and validated a risk prediction model for repeat PCI for recurrent DES-ISR at 1-year follow-up. This model served to generate the ISAR score, a standardised tool that can be used to predict the 1-year risk of repeat PCI for recurrent DES-ISR.


Asunto(s)
Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Stents Liberadores de Fármacos/efectos adversos , Estudios Retrospectivos , Angiografía Coronaria/efectos adversos , Reestenosis Coronaria/etiología , Resultado del Tratamiento , Factores de Riesgo
8.
Clin Res Cardiol ; 112(9): 1231-1239, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36786829

RESUMEN

OBJECTIVE: The aim of this study was to assess the association between high on-aspirin treatment platelet reactivity (HAPR) and the subsequent risk of restenosis after percutaneous coronary intervention (PCI) with predominantly drug-eluting stents. BACKGROUND: The association between HAPR and subsequent risk of restenosis after PCI is unclear. METHODS: This study included 4839 patients undergoing PCI (02/2007-12/2011) in the setting of the Intracoronary Stenting and Antithrombotic Regimen-ASpirin and Platelet Inhibition (ISAR-ASPI) registry. Platelet function was assessed with impedance aggregometry using the multi-plate analyzer immediately before PCI and after intravenous administration of aspirin (500 mg). The primary outcome was clinical restenosis, defined as target lesion revascularization at 1 year. Secondary outcomes included binary angiographic restenosis and late lumen loss at 6- to 8-month angiography. RESULTS: The upper quintile cut-off of platelet reactivity measurements (191 AU × min) was used to categorize patients into a group with HAPR (platelet reactivity > 191 AU × min; n = 952) and a group without HAPR (platelet reactivity ≤ 191 AU × min; n = 3887). The primary outcome occurred in 94 patients in the HAPR group and 405 patients without HAPR (cumulative incidence, 9.9% and 10.4%; HR = 0.96, 95% CI 0.77-1.19; P = 0.70). Follow-up angiography was performed in 73.2% of patients. There was no difference in binary restenosis (15.2% vs. 14.9%; P = 0.79) or late lumen loss (0.32 ± 0.57 vs. 0.32 ± 0.59 mm; P = 0.93) between patients with HAPR versus those without HAPR. CONCLUSIONS: This study did not find an association between HAPR, measured at the time of PCI, and clinical restenosis at 1 year after PCI.


Asunto(s)
Reestenosis Coronaria , Intervención Coronaria Percutánea , Humanos , Aspirina , Inhibidores de Agregación Plaquetaria/uso terapéutico , Fibrinolíticos/uso terapéutico , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/prevención & control , Resultado del Tratamiento , Angiografía Coronaria
9.
Circulation ; 147(7): 575-585, 2023 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-36780380

RESUMEN

BACKGROUND: Although some studies have investigated sex-related outcomes up to 5 years after percutaneous coronary intervention (PCI), analyses at longer follow-up (ie, to 10 years) in large cohorts treated exclusively with drug-eluting stent (DES) platforms are lacking. Therefore, this study aimed to define whether sex-related differences in long-term outcomes after PCI persist both in the DES era and at longer-term follow-up. METHODS: Individual data of patients treated with DES in 5 randomized controlled trials with 10-year follow-up were pooled. Patients were divided into 2 groups by sex. The analysis of individual participant data was performed using a 1-stage approach by entering a clustering effect by parent study in all univariable and multivariable models focusing on sex. The main outcomes of interest for this analysis included cardiovascular death, myocardial infarction, repeat revascularization, and definite stent thrombosis to 10 years after PCI. Survival was analyzed by the Kaplan-Meier method to estimate the time to first event, and differences between the 2 groups were tested with the log-rank test. Hazard ratios (HRs) and 95% CIs were calculated with a Cox proportional hazards model. Conventional multivariable analyses with adjustment for relevant variables were performed. RESULTS: Among 9700 patients undergoing PCI with DES implantation included in the present analysis, 2296 were women and 7404 were men. Through to 10 years, cardiovascular death occurred in 407 of the 2296 female patients and 1012 of the 7404 male patients (adjusted HR [HRadj], 0.94 [95% CI, 0.80-1.11]). Female sex was associated with a lower risk of repeat revascularization of the target lesion (HRadj, 0.80 [95% CI, 0.74-0.87]), target vessel (HRadj, 0.81 [95% CI, 0.76-0.87]), and nontarget vessels (HRadj, 0.69 [95% CI, 0.62-0.77]). Compared with male patients, female patients displayed an increased risk of myocardial infarction in the first 30 days after PCI with DES (HRadj, 1.65 [95% CI, 1.24-2.19]) but a comparable risk of myocardial infarction thereafter. The risk of definite stent thrombosis was not significantly different between female and male patients (HRadj, 1.14 [95% CI, 0.89-1.47]). CONCLUSIONS: Through to 10-year follow-up after PCI with DES, female patients are at increased risk of early myocardial infarction, receive fewer repeat revascularizations, and have no difference in cardiovascular mortality compared with male patients.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Femenino , Humanos , Masculino , Stents Liberadores de Fármacos/efectos adversos , Estimación de Kaplan-Meier , Infarto del Miocardio/complicaciones , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Factores de Riesgo , Caracteres Sexuales , Stents/efectos adversos , Trombosis/etiología , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 101(3): 628-638, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36709496

RESUMEN

OBJECTIVES: To investigate the feasibility and safety of percutaneous transluminal angioplasty (PTA) of the iliofemoral arteries (IFA) before transfemoral transcatheter aortic valve implantation (Tf-TAVI) in patients with advanced peripheral artery disease (PAD). BACKGROUND: Although Tf-TAVI represents the access of choice, alternative vascular access routes are preferred for patients displaying advanced PAD. PTA of the IFA represents a less invasive option, broadening the spectrum of patients eligible for Tf-TAVI. METHODS: All patients requiring PTA of the IFA before Tf-TAVI, between 2012 and 2021, were included. Primary efficacy endpoint was the rate of successful transcatheter heart valve (THV) delivery and implantation. Primary safety endpoint was the rate of PTA and access-site-related vascular complications, procedural- and in-hospital complications. RESULTS: Among 2726 Tf-TAVI procedures, 59 patients required IFA predilation. Successful THV delivery and implantation was achieved in 57 (96.6%) patients, respectively. Sheath placement was achieved in 59 (100%) patients with only one minor dissection and no major vascular complications following iliofemoral PTA. Regarding access site complications, two (3.4%) vessel perforations and one (1.7%) vessel rupture were observed, with eight (13.5%) patients requiring unplanned endovascular interventions. There was one intraprocedural death due to THV-induced vessel laceration, while in-hospital all-cause mortality was 8.5% in the present high-risk patient cohort. CONCLUSIONS: Predilation of IFA is safe and effective in patients with advanced PAD. Careful preprocedural planning is paramount in improving procedural safety and efficacy. This strategy has the potential to broaden the spectrum of patients eligible for Tf-TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad Arterial Periférica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/complicaciones
11.
J Cardiol ; 81(2): 179-188, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36122642

RESUMEN

Bioresorbable scaffolds (BRS) were developed to overcome the obstacles of metallic stents, mostly related to sustained presence of metallic foreign body in the coronary vessel. Following earlier success of single-arm BRS studies, randomized controlled trials of Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, CA, USA) showed poor long-term clinical outcomes, particularly in terms of scaffold thrombosis. BRS made from magnesium alloy provide a promising alternative in terms of radial force, strut thickness and, potentially lower thrombogenicity. A recent clinical study demonstrated that magnesium-based BRS seems to be promising with regards to the risk of scaffold thrombosis. In this review, our aim is to describe the issues that prevented Absorb BVS from achieving favorable outcomes, provide current status of existing BRS technologies and the challenges that newer generation BRSs need to overcome, and the results of clinical studies for commercially available magnesium-based BRS, which remain the only BRS actively studied in clinical practice.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Trombosis , Humanos , Implantes Absorbibles , Magnesio , Diseño de Prótesis , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Enfermedad de la Arteria Coronaria/cirugía
13.
Eur Heart J Cardiovasc Pharmacother ; 9(3): 231-239, 2023 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-36434779

RESUMEN

AIMS: The effect of a prasugrel vs. a ticagrelor based strategy on total (including both first and recurrent) ischaemic and bleeding events in patients with acute coronary syndromes (ACS) has not been evaluated. The aim of this analysis was to investigate the treatment effect of a prasugrel vs. a ticagrelor based strategy in patients with ACS undergoing an invasive management strategy when both first and recurrent non-fatal ischaemic and bleeding events are taken into account. METHODS AND RESULTS: This is a post-hoc analysis of the ISAR-REACT 5 randomized control trial, including all 4018 patients in the trial. The main clinical endpoints of interest included ischaemic events [myocardial infarction (MI) and stroke] and bleeding events [Bleeding Academic Research Consortium (BARC) type 3 to 5 bleeding]. An additional endpoint of interest was definite/probable stent thrombosis. The effect of the prasugrel vs. ticagrelor based strategies on these endpoints was evaluated on both time-to-first event and total events analyses. Patients in the prasugrel group had a lower risk of MI in comparison to the ticagrelor group on both time-to-first event [hazard ratio (HR) = 0.61; 95% confidence interval 0.44-0.85] and total events [HR = 0.62 (0.45-0.86)] analysis. The risk of BARC type 3 to 5 bleeding was comparable between the prasugrel and ticagrelor groups on both time-to-first event [HR = 0.96 (0.75-1.25)] and total events [HR = 0.99 (0.76-1.31)] analysis. CONCLUSION: A prasugrel based strategy was associated with a reduction in total MI events in comparison to a ticagrelor based strategy in patients with ACS undergoing invasive assessment. Total BARC type 3 to 5 bleeding events were comparable between the two groups. Given the importance of this topic, future studies to confirm these findings would be welcome. ClinicalTrials.gov identifier: NCT01944800.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Clorhidrato de Prasugrel/efectos adversos , Ticagrelor/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/tratamiento farmacológico , Infarto del Miocardio/tratamiento farmacológico , Hemorragia/inducido químicamente
14.
EuroIntervention ; 18(14): 1188-1196, 2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36453826

RESUMEN

BACKGROUND: Long-term data concerning the efficacy of different polymer-coating strategies of new-generation drug-eluting stents (DES) in patients with coronary artery calcification (CAC) are scant. AIMS: We aimed to investigate 10-year outcomes by degree of CAC after new-generation DES implantation with different polymer-coating strategies. METHODS: We analysed individual patient and lesion characteristics of patients randomised to treatment with polymer-free sirolimus-eluting, biodegradable-polymer sirolimus-eluting and permanent-polymer zotarolimus- or everolimus-eluting stents. Endpoints of interest at 10 years were all-cause mortality, myocardial infarction (MI), target lesion revascularisation (TLR) and definite or probable stent thrombosis (ST) according to the degree of CAC (no, mild, moderate or severe) and coating strategy (polymer-free vs biodegradable-polymer vs permanent-polymer). RESULTS: A total of 4,953 patients with 6,924 lesions were included. No, mild, moderate or severe CAC was present in 24.5%, 41.8%, 25.8% and 8.0% of patients, respectively. At 10-year follow-up, overall event rates were high, with an incremental increase according to the degree of CAC (all-cause mortality: no 25.3%, mild 32.1%, moderate 41.7%, severe CAC 46.5%; adjusted [adj.] p=0.004; TLR: no 17.4%, mild 16.5%, moderate 19.8%, severe CAC 28.7%; adj. p=0.001; MI: no 4.9%, mild 5.9%, moderate 6.0%, severe CAC 10.5%; adj. p=0.02; and ST: no 1.3%, mild 1.4%, moderate 1.8%, severe CAC 3.6%; adj. p=0.57). In patients with moderate-severe CAC, event rates were comparable, regardless of the DES polymer-coating strategy. CONCLUSIONS: At 10 years after PCI with new-generation DES, there was an incremental increase in adverse events by degree of coronary calcification. These detrimental effects do not seem to be impacted by different polymer-coating strategies.


Asunto(s)
Calcinosis , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Humanos , Stents Liberadores de Fármacos/efectos adversos , Polímeros , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Sirolimus/uso terapéutico , Enfermedad de la Arteria Coronaria/terapia , Infarto del Miocardio/etiología , Calcinosis/complicaciones , Trombosis/etiología , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto
15.
Eur Heart J Cardiovasc Imaging ; 24(1): e1-e16, 2022 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-36002376

RESUMEN

Progression of atherosclerotic plaque in coronary arteries is characterized by complex cellular and non-cellular molecular interactions. Within recent years, atherosclerosis has been recognized as inflammation-driven disease condition, where progressive stages are characterized by morphological changes in plaque composition but also relevant molecular processes resulting in increased plaque vulnerability. While existing intravascular imaging modalities are able to resolve key morphological features during plaque progression, they lack capability to characterize the molecular profile of advanced atherosclerotic plaque. Because hybrid imaging modalities may provide incremental information related to plaque biology, they are expected to provide synergistic effects in detecting high risk patients and lesions. The aim of this article is to review existing literature on intravascular molecular imaging approaches, and to provide clinically oriented proposals of their application. In addition, we assembled an overview of future developments in this field geared towards detection of patients at risk for cardiovascular events.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Enfermedad de la Arteria Coronaria/patología , Imagen Multimodal/métodos , Placa Aterosclerótica/patología , Espectroscopía Infrarroja Corta/métodos , Ultrasonografía Intervencional/métodos
16.
Am J Cardiol ; 176: 15-23, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35606172

RESUMEN

The optimal antiplatelet therapy of patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACS) and chronic kidney disease (CKD) remains unknown. This study included 2,364 patients with NSTE-ACS undergoing predominantly percutaneous coronary intervention (PCI), who were randomized to ticagrelor or prasugrel in the ISAR-REACT 5 trial. Estimated glomerular filtration rate (eGFR) was calculated using the Chronic Kidney Disease Epidemiology Collaboration equation. The primary end point was 1-year mortality. Overall, there were 85 deaths (3.6%): 6 deaths (17.1%) in patients with eGFR <30, 31 deaths (6.9%) in patients with eGFR 30 to <60, 34 deaths (3.0%) in patients with eGFR 60 to <90, and 14 deaths (2.0%) in patients with eGFR ≥90 ml/min/1.73 m2; adjusted hazard ratio (HR)=1.15, 95% confidence interval (CI) 1.01 to 1.31; p = 0.033 for 10 ml/min/1.73 m2 decrement in the eGFR. Bleeding occurred in 129 patients (5.5%): 7 bleeds (20.2%) in patients with eGFR <30, 36 bleeds (8.0%) in patients with eGFR 30 to <60, 64 bleeds (5.6%) in patients with eGFR 60 to <90, and 22 bleeds (3.1%) in patients with eGFR ≥90 ml/min/1.73 m2; adjusted HR=1.11 (1.01 to 1.23); p = 0.045 for 10 ml/min/1.73 m2 decrement in the eGFR. One-year mortality and bleeding did not differ significantly between ticagrelor and prasugrel in all categories of impaired renal function. In conclusion, in patients with NSTE-ACS undergoing PCI with drug-eluting stents and third-generation antiplatelet drugs, impaired renal function was independently associated with higher risk of 1-year mortality and bleeding. The ischemic and bleeding risks appear to differ little between ticagrelor and prasugrel in all categories of impaired renal function.


Asunto(s)
Síndrome Coronario Agudo , Intervención Coronaria Percutánea , Insuficiencia Renal Crónica , Síndrome Coronario Agudo/tratamiento farmacológico , Síndrome Coronario Agudo/cirugía , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Humanos , Isquemia , Riñón/fisiología , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria , Clorhidrato de Prasugrel/uso terapéutico , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/epidemiología , Ticagrelor/uso terapéutico , Resultado del Tratamiento
17.
J Am Heart Assoc ; 11(9): e023493, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-35470682

RESUMEN

Background Stent underexpansion has been known to be associated with worse outcomes. We sought to define optical coherence tomography assessed optimal stent expansion index (SEI), which associates with lower incidence of follow-up major adverse cardiac events (MACEs). Methods and Results A total of 315 patients (involving 370 lesions) who underwent optical coherence tomography-aided coronary stenting were retrospectively included. SEI was calculated separately for equal halves of each stented segment using minimum stent area/mean reference lumen area ([proximal reference area+distal reference area]/2). The smaller of the 2 was considered to be the SEI of that case. Follow-up MACE was defined as a composite of all-cause death, myocardial infarction, stent thrombosis, and target lesion revascularization. Average minimum stent area was 6.02 (interquartile range, 4.65-7.92) mm2, while SEI was 0.79 (interquartile range, 0.71-0.86). Forty-seven (12.7%) incidences of MACE were recorded for 370 included lesions during a median follow-up duration of 557 (interquartile range, 323-1103) days. Receiver operating characteristic curve analysis identified 0.85 as the best SEI cutoff (<0.85) to predict follow-up MACE (area under the curve, 0.60; sensitivity, 0.85; specificity, 0.34). MACE was observed in 40 of 260 (15.4%) lesions with SEI <0.85 and in 7 of 110 (6.4%) lesions with SEI ≥0.85 (P=0.02). Least absolute shrinkage and selection operator regression identified SEI <0.85 (odds ratio, 3.55; 95% CI, 1.40-9.05; P<0.01) and coronary calcification (odds ratio, 2.47; 95% CI, 1.00-6.10; P=0.05) as independent predictors of follow-up MACE. Conclusions The present study identified SEI <0.85, associated with increased incidence of MACE, as the optimal cutoff in daily practice. Along with suboptimal SEI (<0.85), coronary calcification was also found to be a significant predictor of follow-up MACE.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Pronóstico , Estudios Retrospectivos , Stents , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento
18.
Clin Res Cardiol ; 111(7): 827-837, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35476138

RESUMEN

AIMS: Aim of the present study was to investigate the impact of increasing neointimal inhomogeneity and neoatherosclerosis as well as of treatment modality of in-stent restenosis (ISR) on the occurrence of periprocedural myocardial injury (PMI). METHODS AND RESULTS: Patients with normal or stable/falling increased baseline high-sensitivity troponin T (hs-cTnT) undergoing intravascular optical coherence tomography (OCT) and subsequent percutaneous coronary intervention (PCI) of ISR by means of drug-coated balloon (DCB) or drug-eluting stent (DES) were included. Overall, 128 patients were subdivided into low (n = 64) and high (n = 64) inhomogeneity groups, based on the median of distribution of non-homogeneous quadrants. No significant between-group differences were detected in terms of hs-cTnT changes (28.0 [12.0-65.8] vs. 25.5 [9.8-65.0] ng/L; p = 0.355), or the incidence of major PMI (31.2 vs. 31.2%; p = 1.000). Similarly, no differences were observed between DCB- and DES-treated groups in terms of hs-cTn changes (27.0 [10.0-64.0] vs. 28.0 [11.0-73.0] ng/L; p = 0.795), or the incidence of major PMI (28.9 vs. 35.6%; p = 0.566). Additionally, no significant interaction was present between optical neointimal characteristics and treatment modality in terms of changes in hs-cTnT (Pint = 0.432). No significant differences in PMI occurrence were observed between low and high neoatherosclerosis subgroups. CONCLUSIONS: In patients undergoing PCI for ISR, there was no association between increasing neointimal inhomogeneity, or increasing expression of neoatherosclerotic changes and occurrence of PMI. PMI occurrence was not influenced by the treatment modality (DCB vs. DES) of ISR lesions, a finding that supports the safety of DCB treatment for ISR.


Asunto(s)
Reestenosis Coronaria , Stents Liberadores de Fármacos , Lesiones Cardíacas , Intervención Coronaria Percutánea , Angiografía Coronaria/efectos adversos , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Vasos Coronarios/patología , Stents Liberadores de Fármacos/efectos adversos , Lesiones Cardíacas/complicaciones , Humanos , Neointima , Intervención Coronaria Percutánea/efectos adversos , Stents/efectos adversos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
19.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35437213

RESUMEN

INTRODUCTION AND OBJECTIVES: The DECADE cooperation is a pooled analysis of individual patient data from drug-eluting stent (DES) trials with a 10-year follow-up. This analysis reports the risk of definite stent thrombosis (ST) through to 10 years after percutaneous coronary intervention (PCI) in patients treated with early- and new-generation DES. METHODS: Individual patient data from 5 DES trials with a 10-year follow-up were pooled. The primary endpoint was definite ST up to 10 years after PCI. Patients were divided into 2 groups as per the generation of DES implanted (early and new DES). Individual participant data were analyzed using a 1-stage approach. RESULTS: We included 9700 patients, 6866 in the new DES group and 2834 in the early DES group. Through to 10 years, definite ST occurred in 69 of 6866 patients treated with new DES and in 91 of 2834 patients treated with early DES (1.0% vs 3.5%, adjusted hazard ratio, 0.32; 95%CI, 0.23-0.45). The rate of definite ST was lower in the new DES group than in the early DES group from 1 to 5 years (rate ratio, 0.14; 95%CI, 0.08-0.26) and from 5 to 10 years (rate ratio, 0.23; 95%CI, 0.08-0.61) after PCI. CONCLUSIONS: The incidence of definite ST through to 10 years after PCI with new-generation DES was 1%. New-generation DES are associated with a lower 10-year incidence of definite ST than early-generation DES, particularly beyond 1 year after PCI.

20.
J Invasive Cardiol ; 34(4): E266-E273, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35343914

RESUMEN

OBJECTIVES: This study aimed to compare 10-year clinical outcomes in patients with acute coronary syndrome (ACS) treated with new-generation biodegradable-polymer (BP-DES), polymer-free (PF-DES), and permanent-polymer drug-eluting stents (PPDES). METHODS: We analyzed 10-year clinical outcomes for 2042 patients with ACS enrolled in the ISAR-TEST 4 and ISAR-TEST 5 randomized controlled trials. Patients were divided into 3 groups: new-generation PP-DES, BP-DES, and PF-DES. Endpoints of interest included a device-oriented composite endpoint (DOCE) and a patient-oriented composite endpoint (POCE) at 10 years. RESULTS: BP-DES as compared with PP-DES demonstrated a lower DOCE frequency, but this did not meet statistical significance (BP-DES vs PP-DES, 35.4% vs 41.5%, respectively; adjusted hazard ratio (HR), 0.83; 95% confidence interval [CI], 0.68-1.00; P=.05). There was a significantly lower POCE frequency in patients treated with BP-DES compared with PP-DES (65.3% vs 69.0%, respectively; HR, 0.86; 95% CI, 0.75-0.99; P=.04). The relative frequency of the DOCE (41.4% vs 41.5%; HR, 0.97; 95% CI, 0.83-1.15; P=.76) and the POCE (66.8% vs 69.0%; HR, 0.99; 0.87-1.12; P=.82) were comparable in patients treated with PF-DES and PP-DES. CONCLUSION: In patients with ACS, BP-DES were associated with a lower relative frequency of a POCE compared with new-generation PP-DES at 10 years. The relative frequencies of both device- and patient-related outcomes were comparable in patients treated with PF-DES and PP-DES at 10 years.


Asunto(s)
Síndrome Coronario Agudo , Stents Liberadores de Fármacos , Implantes Absorbibles , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/cirugía , Stents Liberadores de Fármacos/efectos adversos , Humanos , Polímeros , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA