Comput Methods Programs Biomed ; 231: 107366, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36720186

RESUMEN

BACKGROUND AND OBJECTIVE: Computer simulations of joint contact mechanics have great merit to improve our current understanding of articular ankle pathology. Owed to its computational simplicity, discrete element analysis (DEA) is an encouraging alternative to finite element analysis (FEA). However, previous DEA models lack subject-specific anatomy and may oversimplify the biomechanics of the ankle. The objective of this study was to develop and validate a personalized DEA framework that permits movement of the fibula and incorporates personalized cartilage thickness as well as ligamentous constraints. METHODS: A linear and non-linear DEA framework, representing cartilage as compressive springs, was established, verified, and validated. Three-dimensional (3D) bony ankle models were constructed from cadaveric lower limb CT scans imaged during application of weight (85 kg) and/or torque (10 Nm). These 3D models were used to generate cartilage thickness and ligament insertion sites based on a previously validated statistical shape model. Ligaments were modelled as non-linear tension-only springs. Validation of contact stress prediction was performed using a simple, axially constrained tibiotalar DEA model against an equivalent FEA model. Validation of ligamentous constraints compared the final position of the ankle mortise to that of the cadaver after application of torque and sequential ligament sectioning. Finally, a combined ligamentous-constraining DEA model was validated for predicted contact stress against an equivalent ligament-constraining FEA model. RESULTS: The linear and non-linear DEA model reproduced a mean articular contact stress within 0.36 MPa and 0.39 MPa of the FEA calculated stress, respectively. With respect to the ligamentous validation, the DEA ligament-balancing algorithm could reproduce the position of the distal fibula within the ankle mortise to within 0.97 mm of the experimental observed distal fibula. When combining the ligament-constraining and contact stress algorithm, DEA was able to reproduce a mean articular contact stress to within 0.50 MPa of the FEA calculated contact stress. CONCLUSION: The DEA framework presented herein offers a computationally efficient alternative to FEA for the prediction of contact stress in the ankle joint, manifesting its potential to enhance the mechanical understanding of articular ankle pathologies on both a patient-specific and population-wide level. The novelty of this model lies in its personalized nature, inclusion of the distal tibiofibular joint and the use of non-linear ligament balancing to maintain the physiological ankle joint articulation.


Asunto(s)
Articulación del Tobillo , Ligamentos , Humanos , Estrés Mecánico , Torque , Peroné
2.
Thorax ; 58(5): 411-6, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12728161

RESUMEN

BACKGROUND: Recent evidence suggests that the frequency response requirements for peak expiratory flow (PEF) meters are higher than was first thought and that the American Thoracic Society (ATS) waveforms to test PEF meters may not be adequate for the purpose. METHODS: The dynamic response of mini-Wright (MW), Vitalograph (V), TruZone (TZ), MultiSpiro (MS) and pneumotachograph (PT) flow meters was tested by delivering two differently shaped flow-time profiles from a computer controlled explosive decompression device fitted with a fast response solenoid valve. These profiles matched population 5th and 95th centiles for rise time from 10% to 90% of PEF and dwell time of flow above 90% PEF. Profiles were delivered five times with identical chamber pressure and solenoid aperture at PEF. Any difference in recorded PEF for the two profiles indicates a poor dynamic response. RESULTS: The absolute (% of mean) flow differences in l/min for the V, MW, and PT PEF meters were 25 (4.7), 20 (3.9), and 2 (0.3), respectively, at PEF approximately 500 l/min, and 25 (10.5), 20 (8.7) and 6 (3.0) at approximately 200 l/min. For TZ and MS meters at approximately 500 l/min the differences were 228 (36.1) and 257 (39.2), respectively, and at approximately 200 l/min they were 51 (23.9) and 1 (0.5). All the meters met ATS accuracy requirements when tested with their waveforms. CONCLUSIONS: An improved method for testing the dynamic response of flow meters detects marked overshoot (underdamping) of TZ and MS responses not identified by the 26 ATS waveforms. This error could cause patient misclassification when using such meters with asthma guidelines.


Asunto(s)
Diagnóstico por Computador/instrumentación , Pruebas de Función Respiratoria/instrumentación , Análisis de Varianza , Humanos , Ápice del Flujo Espiratorio , Presión , Valores de Referencia , Sensibilidad y Especificidad