Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Small ; 20(21): e2308320, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38105422

RESUMEN

The urgent need for the development of micro-thin shields against electromagnetic interference (EMI) has sparked interest in MXene materials owing to their metallic electrical conductivity and ease of film processing. Meanwhile, postprocessing treatments can potentially exert profound impacts on their shielding effectiveness (SE). This work comprehensively compares two reduction methods, hydrazine versus thermal, to fabricate foamed titanium carbonitride (Ti3CNTx) MXene films for efficient EMI shielding. Upon treatment of ≈ 100 µm-thick MXene films, gaseous transformations of oxygen-containing surface groups induce highly porous structures (up to ≈ 74.0% porosity). The controlled application of hydrazine and heat allows precise regulation of the reduction processes, enabling tailored control over the morphology, thickness, chemistry, and electrical properties of the MXene films. Accordingly, the EMI SE values are theoretically and experimentally determined. The treated MXene films exhibit significantly enhanced SE values compared to the pristine MXene film (≈ 52.2 dB), with ≈ 38% and ≈ 83% maximum improvements for the hydrazine and heat-treated samples, respectively. Particularly, heat treatment is more effective in terms of this enhancement such that an SE of 118.4 dB is achieved at 14.3 GHz, unprecedented for synthetic materials. Overall, the findings of this work hold significant practical implications for advancing high-performance, non-metallic EMI shielding materials.

2.
ACS Appl Mater Interfaces ; 15(46): 53847-53858, 2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-37960885

RESUMEN

The fabrication of absorption-dominant electromagnetic interference (EMI) shielding materials is a pressing priority to prevent secondary electromagnetic pollution in miniaturized electronic devices and communication systems. Meeting this goal has remained a tough challenge to keep pace with the rapid evolution of electronics due to the complex compositional and structural design and narrow operating bands. This work articulates a sound and simple strategy to precisely modulate the electrical conductivity of reduced graphene oxide (rGO), as the building block in lightweight double-layered rGO-film/rGO-aerogel/polyvinyl-alcohol (PVA) composites, for efficient microwave absorption over the entire Ku-band frequency range. These constructs reasonably comprised a porous absorption structure built from parallel rGO sheets aligned and prepared via freeze casting followed by freeze drying. The electrical conductivity and impedance of this layer were tuned by varying the annealing temperature from 400 to 800 °C, thereby adjusting the degree of reduction and the absorption characteristic. This layer was backed by a highly conductive rGO film reduced at a high temperature of 1000 °C, with a reflectivity of 97.5%. The incorporation of this film ensured high EMI shielding effectiveness of the double-layered structure through the absorption-reflection-reabsorption mechanism, consistent with the predicted values based on calculated loss factors and the input impedance of the structure. Accordingly, at an average EMI shielding effectiveness of 57.59 dB, the reflection shielding effectiveness (SER) and reflectivity (R) of the assembled composites were optimized to be as low as 0.22 dB and 0.049, respectively. This equates to approximately 99.999% shielding (SET) and ∼95% absorptivity (A) of the incident wave. This study opens new avenues for the development of lightweight (with a density as low as 15 mg/cm3) absorption-dominant EMI shielding composite materials with promising EMI shielding efficiency and potential applications in modern electronics.

3.
HSS J ; 17(2): 213-222, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34421433

RESUMEN

Background: Pedicle screw (PS) placement has been widely used in fusion surgeries on the thoracic spine. Achieving cost-effective yet accurate placements through nonradiation techniques remains challenging. Questions/Purposes: Novel noncovering lock-mechanism bilateral vertebra-specific drill guides for PS placement were designed/fabricated, and their accuracy for both nondeformed and deformed thoracic spines was tested. Methods: One nondeformed and 1 severe scoliosis human thoracic spine underwent computed tomographic (CT) scanning, and 2 identical proportions of each were 3-dimensional (3D) printed. Pedicle-specific optimal (no perforation) drilling trajectories were determined on the CT images based on the entry point/orientation/diameter/length of each PS. Vertebra-specific templates were designed and 3D printed, assuring minimal yet firm contacts with the vertebrae through a noncovering lock mechanism. One model of each patient was drilled using the freehand and one using the template guides (96 pedicle drillings). Postoperative CT scans from the models with the inserted PSs were obtained and superimposed on the preoperative planned models to evaluate deviations of the PSs. Results: All templates fitted their corresponding vertebra during the simulated operations. As compared with the freehand approach, PS placement deviations from their preplanned positions were significantly reduced: for the nonscoliosis model, from 2.4 to 0.9 mm for the entry point, 5.0° to 3.3° for the transverse plane angle, 7.1° to 2.2° for the sagittal plane angle, and 8.5° to 4.1° for the 3D angle, improving the success rate from 71.7% to 93.5%. Conclusions: These guides are valuable, as the accurate PS trajectory could be customized preoperatively to match the patients' unique anatomy. In vivo studies will be required to validate this approach.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA