Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rev. colomb. cardiol ; 29(2): 244-247, ene.-abr. 2022. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1376886

RESUMEN

Resumen La fibrilación auricular es la arritmia más prevalente en la práctica clínica, y se asocia con una morbimortalidad significativa, la cual, en parte, se explica por el riesgo de fenómenos embólicos. En la actualidad, el uso de anticoagulantes es el estándar de manejo en aquellos pacientes con riesgo embólico significativo (dado por un puntaje ≥ 2 en la escala CHA2DS2Vasc). Sin embargo, algunos pacientes tienen contraindicaciones que impiden recibir este tipo de tratamiento a largo plazo, en cuyo caso se considera el cierre percutáneo de la orejuela como medida para la disminución del riesgo de embolia. Al requerir una punción transeptal, la presencia de dispositivos de cierre de defectos del septo interauricular dificulta el procedimiento de manera significativa. Se presenta el caso de una paciente con contraindicación absoluta para recibir anticoagulantes debido a sangrado gastrointestinal y antecedente de cierre percutáneo de comunicación interauricular sometida a cierre percutáneo de orejuela como alternativa terapéutica a la anticoagulación.


Abstract Atrial fibrillation is the most prevalent arrythmia in clinical practice, associated with a significant morbimortality explained, in part, by the high risk of embolic phenomena. The use of anticoagulation is the standard of care in those patients with increased embolic risk (given by a score ≥ 2 in the CHA2DS2Vasc scale). However, some patients have contraindications to receiving this treatment long-term, in which case percutaneous left atrial appendage occlusion can be considered as a means of decreasing their embolic risk. Because the procedure requires transeptal puncture, the presence of devices for atrial septal defect closure can difficult the technique. We present the case of a patient with absolute contraindication to anticoagulation therapy given gastrointestinal bleeding, with history of percutaneous closure of interauricular communication, who was treated with percutaneous left atrial appendage occlusion as an alternative to oral anticoagulants.

2.
Rev. colomb. cardiol ; 27(5): 362-367, sep.-oct. 2020. tab
Artículo en Español | LILACS, COLNAL | ID: biblio-1289243

RESUMEN

Resumen Introducción: La falla cardíaca es un problema de salud pública, cuya prevalencia aumenta con la edad. Hasta el 50% de los casos tiene fracción de eyección preservada. Pocos estudios evalúan arritmias en este tipo de población. Se conoce una asociación con fibrilación auricular, pero se ignora qué otro tipo de arritmias pueden estar presentes. Objetivo: Describir arritmias por medio de monitorización Holter de 24 horas en pacientes con disfunción diastólica. Materiales y métodos: Se realizó un estudio observacional, descriptivo y retrospectivo, en el que se evaluaron y compararon los parámetros de la monitorización Holter de 24 horas en pacientes con disfunción diastólica, provenientes de un solo centro y residentes en Medellín, durante el año 2017. Resultados: 67 pacientes tenían disfunción diastólica; la mayoría correspondió a mujeres (65.7%). El promedio de edad fue 71 años, el índice de masa corporal fue de 26,8 y las comorbilidades más frecuentes fueron hipertensión arterial (68,7%), fibrilación auricular (19,4%) y enfermedad coronaria (19,4%). El promedio de fracción de eyección fue de 58%; el 67,2% tenía disfunción diastólica tipo I y el promedio del volumen de la aurícula izquierda fue de 33 ml/m2. Las arritmias más frecuentes fueron taquicardia atrial no sostenida (40,3%), fibrilación auricular (10,4%), taquicardia ventricular monomórfica (7,5%) y taquicardia por reentrada intranodal (1.5%). Se presentó bloqueo AV de primer grado (22,4%) y bloqueo sinoatrial (1,5%). El promedio de variabilidad de la frecuencia cardíaca fue 126.23. Conclusiones: En pacientes con disfunción diastólica tipo I y II se documentaron varios tipos de arritmias más allá de la fibrilación auricular. No hubo alteraciones en la variabilidad de la frecuencia cardíaca y tampoco en el tiempo de QTc. Dada la existencia de trasfondo fisiopatológico común, se debe evaluar en estudios futuros la relación entre arritmias y disfunción diastólica, además de su potencial tratamiento y modificación de su curso clínico.


Abstract Introduction: Heart failure is a public health problem, with a prevalence that increases with age. Up to 50% of cases have a preserve ejection fraction. Few studies have evaluated arrhythmias in this population type. It is known that there is an association with atrial fibrillation, but other types of arrhythmias that could be present are ignored. Objective: To describe arrhythmias using 24 hour Holter monitoring in patients with diastolic dysfunction. Materials and methods: An observational, descriptive, and retrospective study was performed in which the parameters from 24 hour Holter monitoring were evaluated and compared in patients with diastolic dysfunction from a single centre and resident in Medellin, during the year 2017. Results: A total of 67 patients had diastolic dysfunction, in which the majority (65.7%) were women. The mean age was 71 years, with a mean body mass index of 26.8. The most frequent comorbidities were arterial hypertension (68.7%), atrial fibrillation (19.4%), and coronary disease (19.4%). The mean ejection fraction was 58%; 67.2% had a type I diastolic dysfunction, and the mean atrial volume was 33 ml/m2. The most common arrhythmias were discontinuous atrial flutter (40.3%), atrial fibrillation (10.4%), monomorphic ventricular tachycardia (7.5%) and nodal re-entrant tachycardia (1.5%). First degree AV block (22.4%) and sinoatrial block (1.5%) were observed. The mean heart rate variability was 126.23. Conclusions: Several types of arrhythmias other than atrial fibrillation were documented in patients with type I and type II diastolic dysfunction. There were no changes in the heart rate variability or in the QTc time. Given the existence of a common pathophysiological background, further studies are needed in order to evaluate the relationship between arrhythmias and diastolic dysfunction, as well as any potential treatment and modification of its clinical course.


Asunto(s)
Femenino , Anciano , Arritmias Cardíacas , Insuficiencia Cardíaca Diastólica , Fibrilación Atrial , Taquicardia Ventricular , Frecuencia Cardíaca
3.
Rev. mex. cardiol ; 29(1): 27-36, Jan.-Mar. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1004297

RESUMEN

Abstract: Introduction: The implantable cardioverter defibrillator (ICD) has become the first-line treatment option for SCD prevention. In Colombia, while ICD therapy has been available for several years, extensive registries or studies documenting the impact of ICD therapy are lacking. Objective: To evaluate the association between appropriate and inappropriate ICD therapies and mortality in Colombian patients. Methods: Prospective observational cohort study including 530 patients with cardiomyopathy of varied etiology, from eight clinics in Medellin, Colombia, from 2013 to 2016. Adjusted and survival analyses were performed. Results: Of all participating patients, 72.1% were men, and median age was 64 years. Mean follow-up time was 1.5 ± 0.92 years, with a follow-up rate of 353.3 patients/year. The most common indication for ICD implantation was ischemic heart disease (48.7%), and indication of primary prevention (63.4%). Mortality was 12.8%, and patients with ischemic etiology had 1.8-times greater risk of death compared to non-ischemic patients. 14% of the patients received appropriate therapies, while 13.6% were inappropriate. There was a 65% greater risk of appropriate therapies in patients with ischemic heart disease. High blood pressure, being over 61 years of age, and having left ventricular ejection fraction < 35%, were risk factors for death, while use of beta-blockers was associated with a reduced risk of death. Conclusions: The main indication for ICD was ischemic etiology and primary prevention. Mortality is higher in patients with ischemic etiology, who in addition have increased risk of presenting appropriate therapies. The frequency of device therapies was decreased compared to previous reports.(AU)


Resumen: Introducción: El desfibrilador cardioversor implantable (DCI) se ha convertido en la opción de primera línea de tratamiento para la prevención de la MCS. En Colombia, aunque la terapia DCI ha estado disponible durante varios años, faltan extensos registros o estudios que documenten el impacto de la terapia DCI. Objetivo: Evaluar la asociación entre las terapias apropiadas e inapropiadas de DCI y la mortalidad en pacientes colombianos. Métodos: Estudio prospectivo observacional de cohorte que incluye 530 pacientes con cardiomiopatía de etiología variada, de ocho clínicas en Medellín, Colombia, de 2013 a 2016. Se realizaron análisis ajustados y de supervivencia. Resultados: De todos los pacientes participantes, el 72.1% fueron hombres y la edad mediana fue de 64 años. El tiempo medio de seguimiento fue de 1.5 ± 0.92 años, con una tasa de seguimiento de 353.3 pacientes/año. La indicación más común para la implantación del DCI fue la cardiopatía isquémica (48.7%) y la indicación de prevención primaria (63.4%). La mortalidad fue del 12.8% y los pacientes con etiología isquémica tuvieron un riesgo de muerte 1.8 veces mayor en comparación con los pacientes no isquémicos. Catorce por ciento de los pacientes recibieron terapias apropiadas, mientras que el 13.6% fueron inapropiadas. Hubo un riesgo 65% mayor de terapias apropiadas en pacientes con cardiopatía isquémica. La hipertensión arterial, el tener más de 61 años de edad y haber dejado la fracción de eyección ventricular < 35%, fueron factores de riesgo de muerte, mientras que el uso de betabloqueantes se asoció con un menor riesgo de muerte. Conclusiones: La principal indicación para la DCI fue etiología isquémica y prevención primaria. La mortalidad es mayor en pacientes con etiología isquémica, que además tienen mayor riesgo de presentar terapias apropiadas. La frecuencia de las terapias con dispositivos se redujo en comparación con los informes anteriores.(AU)


Asunto(s)
Humanos , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/provisión & distribución , Estudios Prospectivos , Estudios de Cohortes , Colombia , Cardiomiopatías/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA