Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 39(2): 494-500, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37572716

RESUMEN

BACKGROUND: Knee arthrodesis is a means of avoiding above-knee amputation after a prosthetic joint infection (PJI). The objective of this study was to analyze the results of floating knee arthrodesis in patients who had a history of aprosthetic knee infection. The analysis consisted of determining reinfection rates, functional results, and the survival of arthrodesis. METHODS: There were 48 patients who underwent a cemented floating knee arthrodesis in cases of PJI retrospectively included in the study, having been operated on between 2012 and 2020. In addition to being evaluated clinically, analytically, and radiographically, the patients were assessed functionally by means of a newly-created scale. RESULTS: At a mean follow-up of 4 years (1 year to 9 years), 7 patients suffered reinfection (14.6%). The recurrence of infection was not observed to be significantly affected by sex (P = .16), age(P = .09), or the type of surgery previously undergone (P = .18), nor was the McPherson Host Grade (P = .4) observed to have a significant effect. Patients who had a McPherson Limb Grade 3 were more likely to suffer reinfection than those with a McPherson Limb Grade 2 (P = .034). There were 26 patients (54%)fully evaluated and scored on the Knee Arthrodesis Functional Scale(BAOR). For 11 patients (42%), the results were evaluated as excellent, for 11 (42%) acceptable, for 3 (12%) low, and for 1(4%) poor. CONCLUSION: The arthrodesis nail is an effective and safe procedure for patients who have a recurrent PJI, providing an effective alternative when the criteria for a new revision total knee arthroplasty are not met.


Asunto(s)
Artritis Infecciosa , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Humanos , Reinfección/etiología , Estudios Retrospectivos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Articulación de la Rodilla/cirugía , Artritis Infecciosa/etiología , Artrodesis/efectos adversos , Artrodesis/métodos , Reoperación/efectos adversos , Prótesis de la Rodilla/efectos adversos , Resultado del Tratamiento
2.
Acta Orthop Belg ; 74(6): 801-8, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19205328

RESUMEN

Concern about polyethylene wear and related osteolysis after knee arthroplasty has developed in the last years. Mobile-bearing knee prostheses were designed in order to reduce the influence of this critical factor on long-term success of total knee replacement. We present a prospective study comparing clinical and radiological results with a mobile-bearing (Ceragyr) and a fixed-bearing knee prosthesis (posterior stabilized Hermes). Clinical results did not show any significant differences in Knee Society scores. We found better results in the mobile-bearing group for pain scores and subjective preference, but the difference did not reach statistical significance. Within the time limits of this study, radiological analysis showed no osteolysis in either group, but longer follow-up will be needed to confirm this.


Asunto(s)
Prótesis de la Rodilla , Diseño de Prótesis , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Dolor Postoperatorio/epidemiología , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA