Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
An Acad Bras Cienc ; 93(1): e20190137, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33852714

RESUMEN

This work aims to identify the best treatment condition for removal of chemical oxigen demand (COD) and increase of biodegradability in an advanced oxidative process of photocatalytic ozonation with titanium dioxide (TiO2), applied to the remediation of the leachate produced at the municipal landfill of Campo Mourão, Paraná. The experiment was carried out using a photocatalytic chamber and an ozonation system based on the corona effect. A statistical model of the central composite rotatable design (CCRD) was elaborated and three variables (pH, TiO2 dose and airflow) were analyzed, to define the optimum condition that allows the highest perfomance of the treatment. The statistical model was valid for the data. The best condition identified was: pH = 3.3 TiO2 dose = 0.012 g and flow = 9.0 L.min-1 (8.79 g, O3.min-1). The removal of filtrate COD was approximately 30% and increase in biodegradability (BOD/COD) = 0.59 in the optimum condition. Factors such as the complex composition of the leachate and treatment time were considered as possible limitants for better results. The treatment did not allow to reach the permissible limits for disposal of the effluent at the environment, in Brazil.


Asunto(s)
Ozono , Contaminantes Químicos del Agua , Brasil , Oxidación-Reducción
2.
An. acad. bras. ciênc ; 82(2): 521-537, June 2010. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-548431

RESUMEN

Bed aerators designed to increase air void ratio are used to prevent cavitation and related damages in spillways. Air entrained in spillway discharges also increases the dissolved oxygen concentration of the water, which can be important for the downstream fishery. This study considers results from a systematic series of measurements along the jet formed by a bed aerator, involving concentration profiles, pressure profiles, velocity fields and corresponding air discharges. The experimental results are, then, compared, with results of computational fluid dynamics (CFD) simulations with the aim of predicting the air discharge numerically. Comparisons with jet lengths and the air entrainment coefficients from the literature are also made. It is shown that numerical predictive tools furnish air discharges comparable to measured values. However, if more detailed predictions are desired, verification experiments are still necessary.


Aeradores de fundo projetados para aumentar a concentração de ar são utilizados para previnir a cavitação e danos dela derivados em vertedouros. O oxigênio contido na água também é um parâmetro relevante para garantir alta qualidade das águas a jusante do vertedouro, com reflexos na qualidade ambiental. Equações e critérios de projeto existentes ainda são considerados aproximados, mostrando a necessidade de mais estudos para elucidar os mecanismos que governam o carreamento de ar. Este trabalho apresenta resultados de uma série sistemática de medidas de concentração de ar ao longo da superfície inferior do jato de um aerador de fundo, juntamente com medidas pertinentes de descargas de ar e campos de velocidade da água. Foram feitas comparações com resultados da literatura, considerando perfis de concentração ao longo do jato do aerador até a região de jusante. As medições sob condições controladas forneceram informações necessárias para testar resultados numéricos de aeração obtidos em simulações desses escoamentos, utilizando mecânica dos fluidos computacional (CFD). Mostra-se que ferramentas numéricas preditivas fornecem vazões de ar comparáveis aos valores medidos. Também é concluído que, se detalhes são necessários, experimentos são ainda úteis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA