Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Neth Heart J ; 21(1): 44-6, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23081810

RESUMEN

We describe a 59-year-old patient presenting with ST-elevation acute coronary syndrome. Coronary angiography with intravascular ultrasound (IVUS) showed an important nonsignificant atherosclerotic lesion in the proximal left anterior descending artery (LAD) and presence of bridging in the mid-LAD. Our hypothesis was that focal spasm at this site was the cause of transmural ischaemia; therefore, treatment was given by performing a percutaneous coronary intervention (PCI) of the lesion. The patient remained symptom-free which confirmed our conclusion. The myocardial bridging had no clinical implications at this moment.

4.
Neth Heart J ; 18(2): 90-8, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20200615

RESUMEN

Hybrid imaging of positron emission tomography (PET) together with computed tomography (CT) is rapidly emerging. In cardiology, this new advanced hybrid imaging modality allows quantification of cardiac perfusion in combination with assessment of coronary anatomy within a single scanning session of less than 45 minutes. The near-simultaneous anatomical evaluation of coronary arteries using CT and corresponding functional status using PET provides a wealth of complementary information in patients who are being evaluated for (suspected) coronary artery disease, and could help guide clinical patient management in a novel manner. Clinical experience gained with this recently introduced advanced hybrid imaging tool, however, is still limited and its implementation into daily clinical practice remains largely unchartered territory. This review discusses principles of perfusion PET, its diagnostic accuracy, and potential clinical applications of cardiac PET-CT in patients with ischaemic heart disease. (Neth Heart J 2010;18:90-8.).

5.
Neth Heart J ; 18(12): 598-602, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21301622

RESUMEN

Cardiovascular disease develops 7 to 10 years later in women than in men and is still the major cause of death in women. The risk of heart disease in women is often underestimated due to the misperception that females are 'protected' against cardiovascular disease. The under-recognition of heart disease and differences in clinical presentation in women lead to less aggressive treatment strategies and a lower representation of women in clinical trials. Furthermore, self-awareness in women and identification of their cardiovascular risk factors needs more attention, which should result in a better prevention of cardiovascular events. In this review we summarise the major issues that are important in the diagnosis and treatment of coronary heart disease in women. (Neth Heart J 2010;18:598-603.).

6.
Int J Card Imaging ; 16(4): 267-77, 2000 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11219598

RESUMEN

OBJECTIVES: Evaluation of the long-term functional outcome assessed by exercise myocardial perfusion imaging following excimer laser angioplasty compared to balloon angioplasty in coronary lesions > 10 mm in length. BACKGROUND: Previous randomized studies evaluating the effect of coronary interventions mainly focused on the long-term clinical and angiographic outcome. The functional outcome, assessed by myocardial perfusion scintigraphy, has not been evaluated in a randomized setting. METHODS: A total of 308 patients with stable angina and a longer coronary lesion (> 10 mm) were randomized to excimer laser angioplasty or balloon angioplasty. A 99mTechnetium-2-methoxy isobutyl isonitrile (MIBI) single-photon emission computed tomography (SPECT) study was performed in 139 patients before the initial angioplasty procedure and at 6 months follow-up (73 patients in the laser group versus 66 patients in the balloon group, respectively). Exercise tolerance at follow-up was compared to baseline values by means of exercise duration and double product at peak exercise. Myocardial perfusion of the randomized vascular bed was assessed semi-quantitatively on the MIBI SPECT images. The reversible defects were graded as mild, moderate or severe. Myocardial perfusion at follow-up was expressed as a percentage reduction in incidence and grading of the reversible defects compared to baseline values. RESULTS: Forty-four (61%) patients assigned to laser angioplasty were asymptomatic at 6 months follow-up compared to 34 (52%) patients assigned to balloon angioplasty (p = NS). Improvement in exercise duration and double product were 0.7 +/- 2.1 min and 4.3 +/- 6.2 min/mmHg/l,000, respectively, in the laser group, versus 0.3 +/- 2.5 min and 3.1 +/- 5.5 min/mmHg/1,000, respectively, in the balloon group (both p = NS). The percentage reduction of reversible defects was 23% in patients assigned to laser angioplasty vs. 29% in patients assigned to balloon angioplasty (Relative risk [RR]: 0.79, 95% confidence interval [CI]: 0.40-1.57; p = 0.50). The mild, moderate and severe reversible defects improved in 44.4, 63.6 and 66.6%, respectively, in the laser angioplasty group vs. 66.6, 53.8 and 90%, respectively, in the balloon angioplasty group. None of the comparisons were significantly different. CONCLUSION: Excimer laser angioplasty compared to balloon angioplasty in coronary lesions > 10 mm in length yields a similar long-term functional outcome assessed by anginal status, exercise tolerance and myocardial perfusion.


Asunto(s)
Angioplastia de Balón Asistida por Láser/métodos , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/cirugía , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/cirugía , Intervalos de Confianza , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Tecnecio Tc 99m Sestamibi , Resultado del Tratamiento
7.
Int J Card Imaging ; 14(1): 19-26, 1998 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9559375

RESUMEN

This study evaluated an analogue laser optical disc (MVP) as an alternative for cinefilm angiography in the visual analysis of coronary angiograms. Visual analysis was performed independently by 5 observers using cinefilm and MVP before and after PTCA (194 coronary lesions in 88 patients) and the outcomes were compared with QCA. The mean percentage diameter stenosis on cinefilm and MVP yielded similar results compared to QCA. Regression analysis showed a good correlation between the mean cinefilm and MVP values per diameter stenosis (p < 0.001). Bland-Altman plots confirmed these findings. Qualitative analysis for detection of coronary dissections after PTCA showed an incidence of 31.3% (cinefilm) and 21.8% (MVP) (p < 0.05). The results of this study indicate that the visual analysis of the coronary angiograms using the analogue laser optical disc (MVP) yields similar results compared to the cinefilm concerning coronary lesion severity, although there is an underestimation of coronary dissections.


Asunto(s)
Enfermedad Coronaria/diagnóstico , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/instrumentación , Imagen por Resonancia Cinemagnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón , Enfermedad Coronaria/terapia , Vasos Coronarios/patología , Femenino , Tecnología de Fibra Óptica , Humanos , Rayos Láser , Modelos Lineales , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
8.
Heart ; 79(1): 34-8, 1998 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9505916

RESUMEN

OBJECTIVES: To compare clinical outcome in patients with complex coronary lesions treated with either excimer laser coronary angioplasty (ELCA) or balloon angioplasty. PATIENTS AND DESIGN: 308 patients with stable angina and a coronary lesion of more than 10 mm in length were randomised to ELCA (151 patients, 158 lesions) or balloon angioplasty (157 patients, 167 lesions). The primary clinical end points were death, myocardial infarction, coronary bypass surgery, or repeated coronary angioplasty of the randomised segment during six months of follow up. Subanalysis was performed to identify a subgroup of patients with a beneficial clinical outcome following ELCA or balloon angioplasty. SETTING: Two university hospitals and one general hospital. RESULTS: There were no deaths. Myocardial infarction, coronary bypass surgery, and repeated angioplasty occurred in 4.6, 10.6, and 21.2%, respectively, of patients treated with ELCA compared with 5.7, 10.8, and 18.5%, respectively, of those treated with balloon angioplasty. ELCA did not yield a favourable clinical outcome in subgroups of patients with long (more than 20 mm) coronary lesions, calcified lesions, small diseased vessels (< or = 2.5 mm reference diameter), or total coronary occlusions. There was a worse clinical outcome in patients with tandem lesions treated with ELCA compared with balloon angioplasty (9/18 v 3/26 lesions; p = 0.01); while a trend towards an unfavourable clinical outcome was found in patients with vessels with a reference diameter of more than 2.5 mm (23/66 v 13/63 lesions, p = 0.07) and left circumflex coronary lesions (12/41 v 6/42 lesions, p = 0.08). CONCLUSIONS: The findings indicate a worse clinical outcome in patients with lesions of more than 10 mm treated with ELCA compared with balloon angioplasty who have tandem coronary lesions and in those with vessels with a reference diameter of more than 2.5 mm and left circumflex coronary lesions.


Asunto(s)
Angioplastia de Balón Asistida por Láser , Angioplastia de Balón , Enfermedad Coronaria/terapia , Anciano , Distribución de Chi-Cuadrado , Angiografía Coronaria , Puente de Arteria Coronaria , Enfermedad Coronaria/mortalidad , Enfermedad Coronaria/cirugía , Vasos Coronarios/patología , Estudios de Evaluación como Asunto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Reoperación , Resultado del Tratamiento
9.
Am J Cardiol ; 78(7): 757-62, 1996 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-8857478

RESUMEN

Registries of excimer laser coronary angioplasty have reported good results in the treatment of complex coronary artery disease, including total or subtotal coronary occlusions. One hundred three patients (103 lesions) with a functional or total coronary occlusion were included in a randomized trial (Amsterdam-Rotterdam [AMRO] trial, total of 308 patients), 49 patients were allocated to laser angioplasty and 54 patients to balloon angioplasty. The primary clinical end points were death, myocardial infarction, coronary bypass surgery, or repeated coronary angioplasty of the randomized segment during a 6-month follow-up period. The primary angiographic end point was the minimal lumen diameter at follow-up in relation to the baseline value (net gain), as determined by an automated contour-detection algorithm. Laser angioplasty was followed by balloon angioplasty in all procedures. The angiographic success rate was 65% in patients treated with excimer laser-assisted balloon angioplasty compared with 61% in patients treated with balloon angioplasty alone. No deaths occurred. There were no significant differences between the laser angioplasty group and the balloon angioplasty group in the incidence of myocardial infarctions (1 patient vs 3, respectively, p = 0.36), coronary bypass surgery (4 patients vs 2, respectively, p = 0.34), repeat angioplasty (10 patients vs 8, respectively, p = 0.46) or primary clinical end point (15 patients vs 12, respectively, p = 0.34). The net gain in minimal lumen diameter and restenosis rate (>50% diameter stenosis at follow-up) were 0.81 +/- 0.74 mm and 66.7%, respectively, in patients treated with laser angioplasty compared with 1.04 +/- 0.68 mm and 48.5%, respectively, in patients treated with balloon angioplasty (p = 0.59 and p = 0.15, respectively). Excimer laser-assisted balloon angioplasty demonstrated no benefit over balloon angioplasty with respect to initial and long-term clinical and angiographic outcome in the treatment of patients with functional or total coronary occlusions of >10 mm in length.


Asunto(s)
Angioplastia de Balón Asistida por Láser , Angioplastia de Balón , Enfermedad Coronaria/terapia , Adulto , Anciano , Angioplastia de Balón/efectos adversos , Angioplastia de Balón Asistida por Láser/efectos adversos , Distribución de Chi-Cuadrado , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Vasoespasmo Coronario/etiología , Vasos Coronarios/lesiones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Recurrencia , Heridas Penetrantes/etiología
10.
Lasers Surg Med ; 18(2): 197-205, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8833290

RESUMEN

BACKGROUND AND OBJECTIVE: The relationship between tissue ablation volume and the formation of insoluble gas of the currently available excimer laser systems is unknown. This aspect was evaluated in two excimer laser systems. STUDY DESIGN/MATERIALS AND METHODS: We measured tissue ablation volume and gas production of two excimer laser systems (308 nm) on porcine aortic tissue immersed in saline (the CVX-300 using 1.4 and 1.7 mm laser catheters and the Dymer 200 + using 1.3, 1.3z and 1.6 mm laser catheters). RESULTS: Tissue ablation volume and gas production increased proportionally with the applied energy fluence, ranging from 30-60 mJ/mm2. The gas production per unit of ablated tissue volume of the 1.4 mm laser catheter was significantly higher than the 1.3 mm laser catheter (mean difference +117%, 95% CI from +64% till +188%, P<0.001). The gas production of the 1.7 mm laser catheter was higher than the 1.6 mm laser catheter (mean difference +70%, 95% CI from +28% till +126%, P<0.001). The 1.3z mm laser catheter demonstrated more gas production than the 1.3 mm laser catheter (mean difference +123%, 95% CI from +68% till +196%, P<0.001). CONCLUSION: The results of our study indicate that excimer laser with the use of the CVX-300 laser system results in significantly higher gas production than the Dymer 200+ laser system, which can be markedly reduced by lowering the applied energy fluence. The 1.3z laser catheter constitutes an exception, showing similar characteristics as the CVX-300 laser catheters.


Asunto(s)
Aorta/cirugía , Gases , Terapia por Láser , Animales , Aorta/patología , Técnicas In Vitro , Porcinos
11.
Lancet ; 347(8994): 79-84, 1996 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-8538345

RESUMEN

BACKGROUND: Excimer laser coronary angioplasty is reported to give excellent procedural results for treatment of complex coronary lesions, but this method has not been compared with balloon angioplasty in a randomised trial. METHODS: Patients (n = 308) with stable angina and coronary lesions longer than 10 mm on visual assessment were included. 151 patients (158 lesions) were assigned randomly to laser angioplasty and 157 (167 lesions) to balloon angioplasty. The primary clinical endpoints were death, myocardial infarction, coronary bypass surgery, or repeat coronary angioplasty of the randomised segment during 6 months of follow-up. The primary angiographic endpoint was the minimal lumen diameter at follow-up in relation to the baseline value (net gain), as determined by quantitative coronary angiography. FINDINGS: Laser angioplasty was followed by balloon angioplasty in 98% of procedures. The angiographic success rate was 80% in patients treated with laser angioplasty compared with 79% in patients treated with balloon angioplasty. There were no deaths. Myocardial infarction, coronary bypass surgery, and repeat angioplasty occurred in 4.6%, 10.6%, and 21.2%, respectively, of the patients in the laser angioplasty group compared with 5.7%, 10.8%, and 18.5% of the balloon angioplasty group. Net mean (SD) gain in minimal lumen diameter was 0.40 (0.69) mm in patients treated with laser angioplasty and 0.48 (0.66) mm in those treated with balloon angioplasty (p = 0.34). The restenosis rate (> 50% diameter stenosis) was 51.6% in the laser angioplasty group versus 41.3% in the balloon angioplasty group (p = 0.13). INTERPRETATION: Excimer laser angioplasty followed by balloon angioplasty provides no benefit additional to balloon angioplasty alone with respect to the initial and long-term clinical and angiographic outcome in the treatment of obstructive coronary artery disease.


Asunto(s)
Angioplastia Coronaria con Balón , Angioplastia de Balón Asistida por Láser , Enfermedad Coronaria/cirugía , Enfermedad Coronaria/terapia , Adulto , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA