1.
Radiat Prot Dosimetry ; 172(4): 341-345, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26656077

RESUMEN

Measurements described in this article were carried out with the aim of evaluating risks of the patient exposure to secondary neutrons during treatment at the Proton Therapy Centre Prague. The neutron spectral fluence was measured by means of the extended Bonner sphere spectrometer (EBS). The article presents secondary neutron spectral fluences obtained by the EBS with passive thermoluminescent detectors, i.e. pairs of 6LiF and 7LiF chips. Measurements were performed in two positions: the first one behind the Nylon 6 phantom, and the second one close to the range shifter to evaluate their contribution to the generation of neutrons. Both the Nylon 6 phantom and the range shifter were irradiated with a pencil beam of protons 4 mm in diameter and the energy of 200 MeV. The results are supplemented with the values of effective dose derived from neutron spectral fluences.


Asunto(s)
Neutrones , Fantasmas de Imagen , Terapia de Protones/efectos adversos , Radiometría/instrumentación , Humanos , Terapia de Protones/instrumentación , Terapia de Protones/métodos , Dosis de Radiación , Radiometría/métodos
2.
Prague Med Rep ; 107(3): 317-26, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17385404

RESUMEN

Success of advanced cardiac life support (ACLS) depends on several factors: character and severity of the primary insult, time interval between cardiac arrest and effective basic life support (BLS) and the ensuing ACLS, patient's general condition before the insult, environmental circumstances and efficacy of BLS and ACLS. From these factors, only the efficacy of ACLS is under control of emergency personnel. The end tidal partial pressure of CO2 (P(ET)CO2) has been shown to be an indicator of the efficiency of ACLS and a general prognostic marker. In this study P(ET)CO2 was monitored during out-of hospital ACLS in three cases of cardiac arrest of different aetiology. The aetiology included lung oedema, tension pneumothorax and high voltage electric injury. P(ET)CO2 served for adjustments of ACLS. In these three cases the predictive value of P(ET)CO2 monitoring corresponded to previously reported recommendations.


Asunto(s)
Apoyo Vital Cardíaco Avanzado , Capnografía , Monitoreo Fisiológico , Adolescente , Adulto , Anciano , Dióxido de Carbono/análisis , Reanimación Cardiopulmonar , Femenino , Humanos , Masculino