Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Photodiagnosis Photodyn Ther ; : 104333, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39245304

RESUMEN

BACKGROUND: Hybrid ceramics bonding with the dentinal substrate is crucial for clinical success and longevity. To enhance adhesion, the surface of ceramic restorations is modified through various conditioning techniques AIM: Effect of Different Surface Conditioners Erbium-doped yttrium aluminum garnet (ER: YAG) laser and Low-level laser therapy (LLLT) activated Methylene blue (MB) on the surface roughness (Ra) and shear bond strength (SBS) of Polymer infiltrating ceramic network (PICN) discs bonded using different viscosity resin cement before and after thermal aging. MATERIAL AND METHODS: One hundred and fifty human central incisors and one hundred and fifty-three PICN discs were prepared. PICN discs were randomly allocated into three groups based on the surface conditioning(n=51) Group 1:10% HF acid-S, Group 2: LLLT (MB), and Group 3: Er: YAG laser. Following conditioning Ra scores of ten samples were performed. Surface topography of samples was performed using a scanning electron microscope (SEM). Bonding of forty PICN discs from each conditioning group was performed with high (A) or low viscosity (B) dual-curing resin cement (n= 20 each). Each subgroup was divided into two cohorts and subjected to varying storage conditions. The SBS test and failure mode analysis were performed using a universal testing machine and stereomicroscope. Descriptive statistics of SBS and Ra for each group were analyzed using ANOVA and Tukey post hoc tests. HF acid-S attained the highest Ra scores. RESULTS: Group 1A (HF-S+HIGH) samples achieved the highest SBS values at baseline. Group 3A, on the other hand, displayed the lowest bond score (Er: YAG laser+HIGH) after thermal aging. Intergroup comparison analysis at baseline unveiled that Group 1A and Group 1B (HF(S) + LOW) displayed no significant difference in their bond strength scores (p>0.05). Following artificial aging, it was observed that Group 2A (LLLT (MB) + HIGH) and Group 3A (Er:YAG laser + HIGH) ) presented comparable SBS(p>0.05). Thermal aging decreased SBS significantly in all groups. PICN conditioned with HF-S results in high surface roughness. CONCLUSION: PICN conditioned with HF acid with silane and bonded with low-viscosity resin cement to the dentinal substrate is preferable. Aging influences SBS.

2.
Int Dent J ; 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38851931

RESUMEN

Dental radiography is widely used in dental practices and offers a valuable resource for the development of AI technology. Consequently, many researchers have been drawn to explore its application in different areas. The current systematic review was undertaken to critically appraise developments and performance of artificial intelligence (AI) models designed for tooth numbering and detection using dento-maxillofacial radiographic images. In order to maintain the integrity of their methodology, the authors of this systematic review followed the diagnostic test accuracy criteria outlined in PRISMA-DTA. Electronic search was done by navigating through various databases such as PubMed, Scopus, Embase, Cochrane, Web of Science, Google Scholar, and the Saudi Digital Library for the articles published from 2018 to 2023. Sixteen articles that met the inclusion exclusion criteria were subjected to risk of bias assessment using QUADAS-2 and certainty of evidence was assessed using GRADE approach.AI technology has been mainly applied for automated tooth detection and numbering, to detect teeth in CBCT images, to identify dental treatment patterns and approaches. The AI models utilised in the studies included exhibited a highest precision of 99.4% for tooth detection and 98% for tooth numbering. The use of AI as a supplementary diagnostic tool in the field of dental radiology holds great potential.

3.
Photodiagnosis Photodyn Ther ; 47: 104210, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38729233

RESUMEN

AIM: Different remineralizing pretreatments Casein phosphopeptide-amorphous calcium phosphate fluoride (CPP-ACPF), tricalcium phosphate fluoride (TCP-F), self-assembling peptide (SAP) P11-4 and 10 % Nanohydroxyapatite (nHA) gel activation via invisible infrared light on the dentin microhardness (MH) and micro shear bond strength (µSBS) of composite restoration. METHODS: Seventy-five human molar teeth were collected and the dentinal surface of all the samples was exposed to different demineralizing solutions. (n = 15) Group 1 (demineralized dentin), Group 2 (CPP ACP), Group 3 (TCP-F), Group 4 (SAP P11-4), Group 5 (nHA gel activation via invisible infrared light). MH assessment was performed using Vickers hardness. Each group of 10 samples was subjected to composite restoration buildup and µSBS were tested. The debonded samples were then observed under a stereo-microscope for failure analysis. ANOVA was conducted, along with Tukey's post hoc analysis, to examine the µSBS of composite and MH of the remineralized surface. RESULTS: nHA gel activation via invisible infrared light pretreated specimens showed the maximum outcomes of surface hardness (331.2 ± 77.3) and bond strength (10.38 ± 2.77). However, Group 4 (SAP P11-4) (148.3 ± 29.2) remineralized dentin displayed minimum scores of MH and µSBS (5.88 ± 1.01). CONCLUSION: Remineralizing pretreatment nHA gel activation via invisible infrared light and casein phosphopeptide-amorphous calcium phosphate fluoride seem to improve the dentin MH and µSBS of the composite restoration.


Asunto(s)
Caseínas , Remineralización Dental , Caseínas/farmacología , Caseínas/química , Humanos , Remineralización Dental/métodos , Dentina/efectos de los fármacos , Dureza , Rayos Infrarrojos , Resistencia al Corte , Durapatita/química , Durapatita/farmacología , Diente Molar , Fosfatos de Calcio/farmacología , Fosfatos de Calcio/química , Restauración Dental Permanente/métodos
4.
Oral Health Prev Dent ; 21(1): 291-296, 2023 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-37724899

RESUMEN

PURPOSE: The goal of this study was to assess the peri-implant condition, peri-implant bone loss (PBL), and complication rates of short dental implant-supported splinted crowns (SDI-SCs) and non-splinted crowns (SDI-NSCs) in the maxillary premolar-molar region. MATERIALS AND METHODS: Patients who had short implants placed near their maxillary sinuses were evaluated. Both patient satisfaction and presence of any technical complication, e.g. porcelain wear and chipping, loss of retention and loosening of the abutment, fixture or screw, were noted. The peri-implant plaque index (PIPI), probing depth (PIPD), bleeding on probing (PIBP), and peri-implant bone loss (PBL) were evaluated. To assess the impact of prosthesis type and SDI placement on technical problems, a log-rank test was computed. p < 0.05 was considered statistically significant. RESULTS: A total of 72 patients agreed to be followed-up, showing a mean follow-up time of 3.1 years. Ninty-five implants in total (55 SDI-SCs, and 40 SDI-NSCs) with moderately rough surfaces were evaluated. The average PBL score for implant and patients was 1.27 (0.02-3.97) and 1.25 (0.03-4.41), respectively. More technical complications were observed with single crowns than with splinted crowns. There were no statistically significant differences in the peri-implant parameters between SDI-SCs and SDI-NSCs (p > 0.05). PBL at molar sites was substantially higher than at premolar sites (p = 0.048). Sixty patients (83.3%) were satisfied with the appearance of the crowns, while 57 patients (79.1%) were satisfied with the crowns' performance. CONCLUSION: The peri-implant conditions, bone levels, technical complication rates and patient satisfaction were comparable between the SDI-SCs and SDI-NSCs. However, implants placed in the molar sites had statistically significantly greater bone loss in comparison to those at the premolar sites.


Asunto(s)
Implantes Dentales , Satisfacción del Paciente , Humanos , Diente Premolar , Estudios Retrospectivos , Diente Molar/diagnóstico por imagen
5.
Photodiagnosis Photodyn Ther ; 40: 103074, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36028171

RESUMEN

AIM: To assess and equate the efficacy of different disinfection protocols autoclave, chlorhexidine (CHX), PDT utilizing Rose Bengal (RB), chitosan, and Er, Yag laser and their effect on fracture strength of PMMA denture-based polymer (DBP) colonized with C. Albicans, S. aureus, S.mutans, and E.coli. MATERIAL AND METHODS: A total of 50 (n = 10) PMMA DBP were manufactured and adulterated with the American Type Culture Collection (ATCC) of diverse microbial colonies inhabited by C. Albicans, S. aureus, S.mutans, and E.coli. The specimens were subjected to different denture disinfection approaches by randomly distributing in into five groups i.e., Er, Yag laser, RB, autoclave, CHX, and Chitosan, respectively for appraising antimicrobial effectiveness. PMMA fracture load was also assessed and statistical analysis was performed for CFU/mL (log10) of exposed C. Albicans, S. aureus, S.mutans, and E.coli by one-way ANOVA and Tukey's multiple comparison test at a significance level of p < 0.05. RESULTS: Intergroup comparison disclosed that denture disinfection with Er, Yag laser, autoclave, Chitosan, and CHX (control) validated comparable antimicrobial efficacy to denture against all inspected CFU/mL (log10) (p>0.05). The intragroup comparison revealed that DBP sanitization with Er, Yag laser, autoclave, Chitosan, RB, and CHX substantiated equivalent effective antimicrobial efficacy in plummeting CFU/mL (log10) of S. mutans and E. coli (p>0.05) but in consideration to S.aureus and C.albicans, all groups resulted in declining their count except 5µm RB activated by PDT(p < 0.05). No significant difference was perceived in fracture load of PMMA denture base among Er, Yag laser, RB, chitosan, and CHX (control) (p > 0.05) except autoclave decontamination procedure that indicated the least fracture strength of DBP when disinfected (p < 0.05). CONCLUSION: Er, Yag laser, and Chitosan activated by PDT have the potential to be used as an alternative to chlorhexidine for disinfecting Polymethyl methacrylate denture base as they demonstrated the highest antimicrobial efficacy against E. coli, C. Albicans, S aureus, and S. mutans with optimal fracture load.


Asunto(s)
Quitosano , Láseres de Estado Sólido , Staphylococcus aureus Resistente a Meticilina , Fotoquimioterapia , Láseres de Estado Sólido/uso terapéutico , Polimetil Metacrilato , Candida albicans , Escherichia coli , Staphylococcus aureus , Resistencia Flexional , Polímeros , Fotoquimioterapia/métodos , Clorhexidina/farmacología
6.
Saudi J Biol Sci ; 29(1): 622-629, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35002459

RESUMEN

OBJECTIVES: Peri-implantitis is a destructive inflammatory process that affects the soft and hard tissues around dental implants. porphyromonas gingivalis, an anaerobic gram-negative bacterium, appears to be the main culprit. Since there is no efficient and specific vaccine to treat peri-implantitis, the goal of our research has been to develop a multi-epitope vaccination utilizing an immunoinformatics approach that targeted P. gingivalis type I fim A. MATERIALS AND METHODS: P. gingivalis peptides 6JKZ and 6KMF are suitable for vaccine development. B- and T-cell epitopes from 6KMF and 6JKZ were detected and evaluated based on critical factors to produce a multi-epitope vaccine construct. It was assessed based on allergenicity, antigenicity, stability. The vaccine's dual major histocompatibility complex (MHC-I and MHC-II) binding epitopes allowed it to reach a larger population. P. gingivalis fimbriae induce immune subversion through TLR -CXCR4 receptor complex pathway. The ClusPro 2.0 server was used to do the molecular docking using TLR2 - CXCR4 and vaccine epitopes as receptor and ligand respectively. RESULTS: The designed vaccine was non-allergenic and had a high antigenicity, solubility, and stability. The 3D structure of the vaccine revealed strong interaction with CXCR4(TLR2) using molecular docking. The vaccine-CXCR4 interface was more consistent, possibly because the vaccination has a higher affinity for the CXCR4-TLR2 complex. CONCLUSION: This study details the vaccine's distinct and sustained interaction with the CXCR4(TLR2) immunological receptor and its consistent and effective utterance in the bacterial system. As a result, our vaccine formulation will evoke a significant memory response and induce an adaptive immune response against P. gingivalis.

7.
Photodiagnosis Photodyn Ther ; 37: 102566, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34619385

RESUMEN

AIM: To assess the effectiveness of chemical, ultrasonic and photodynamic therapy (PDT) mediated disinfection against in-vitro biofilms colonized with C. albicans, S. oralis, and S. aureus on surfaces of PMMA (polymethylmethacrylate) denture base material. MATERIALS AND METHODS: Fifty plates of PMMA were prepared with two different surface topography (rough and polished) analyzed by profilometry. Provenance culture (ATCC) of C. albicans, S. oralis, and S. aureus were inoculated on specimens and exposed to disinfection. The disinfection included Rosebengal (RB) 5 µM activated by a red LED, 2% glutaraldehyde, 70% Isopropyl alcohol, ultrasonic disinfection, and saline solution as a control. The antimicrobial efficacy was assessed by subsequently calculating viable counts after disinfection. The data were analyzed using analysis of variance (ANOVA) and Tukey's Post Hoc test. RESULTS: The unpolished surface demonstrated the highest average surface roughness As 5.32±0.36 (µm) and root mean square roughness Rr 7.22±0.81 (µm) compared to the polished surface. Intergroup comparison demonstrated polished and rough PMMA plate disinfected with rose bengal, glutaraldehyde and alcohol-based disinfection exhibited comparable reduction against C. albicans and S. oralis CFU/mL (log10) (p>0.05). Whereas, this reduction was significantly higher on the rough and polished surface of PMMA when disinfected using ultrasounds for 30 sec (p<0.05). Rose Bengal was the most effective method of disinfection against S. aureus both on polished (0.17±0.13) and rough (0.44±0.22) denture plates (p<0.05). CONCLUSION: The ultrasonic disinfection was most effective in reducing viable microbial counts. RB mediated PDT exhibited a more substantial reduction of the colonies of S.aureus.


Asunto(s)
Desinfección , Fotoquimioterapia , Resinas Acrílicas/farmacología , Candida albicans , Bases para Dentadura , Desinfección/métodos , Glutaral/farmacología , Ensayo de Materiales , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/farmacología , Polimetil Metacrilato/farmacología , Staphylococcus aureus , Ultrasonido
8.
Curr Med Imaging ; 18(8): 855-861, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34879811

RESUMEN

BACKGROUND: Dental implants are considered the first option to replace missing teeth. Alveolar bone resorption gradually progresses following tooth extraction leading to loss of vertical bone dimension for implant placement. The lateral window approach is the most commonly used procedure to treat vertical bone loss. OBJECTIVE: The aim of the present study is to evaluate the Lateral Wall Thickness (LWT) of the maxillary sinus and determine the influence of gender and side on maxillary LWT. METHODS: This study involved a cross sectional retrospective study. Cone- beam computed tomography data were collected from 99 patients with a total of 198 maxillary sinuses that met the inclusion criteria. The patient age ranged between 18 to 35 years. On the selected sagittal section, the points of measurement are determined by a perpendicular line at 5 mm from the lowest point of the sinus floor. Measurements were taken at four different areas; first premolar (P1), second premolar (P2), first molar (M1), and second molar (M2). Descriptive statistics were used to calculate mean lateral wall thickness for each tooth, and student's t-test was used to test the effect of gender and side on maxillary LWT. RESULTS: The greatest mean LWT was observed around the left first maxillary molar (2.43±0.82), while the lowest mean LWT was observed around the right second maxillary premolar (1.62±0.61). There was no significant difference in the LWT around any tooth (M1 p=0.56, M2 p=0.92, P1 p=0.14, P2 p=0.19). CONCLUSION: There was no significant difference in both males and females of the lateral wall thickness in the left and right side of maxillary sinus.


Asunto(s)
Seno Maxilar , Elevación del Piso del Seno Maxilar , Adolescente , Adulto , Tomografía Computarizada de Haz Cónico/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Seno Maxilar/diagnóstico por imagen , Estudios Retrospectivos , Adulto Joven
9.
Saudi Dent J ; 33(8): 958-964, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34938038

RESUMEN

AIM: To assess the relations between the divergence angle of the maxillary molar roots and their proximity to the maxillary sinus floor using CBCT. METHOD: This study comprised CBCT scans of the maxilla, including at least the inferior one-third of the maxillary sinus and at least one molar present in any quadrant with complete eruption and root formation. Evaluation included the vertical relations between the maxillary molar root apices and the maxillary sinus floor (MSF), and the root divergence was measured from the root apices to the floor of the pulp chamber. The chi-square test was used for the associations between the study parameters. For the correlation between root divergence angles and MSF vertical relationship types, the Spearman test was used. A P-value < 0.05 was considered significant. RESULTS: A total of 100 scans were analyzed, including 316 permanent maxillary first and second molars. The MSF Type II vertical relationship was the most prevalent (39.6%), followed by Type I (31.3%). The highest divergence angle was found between the distobuccal and palatal roots (mean = 44.9 ± 10.5°). For the mesiobuccal-distobuccal angle groups, there were higher percentages of the MSF Type I and II relationships among the angle groups < 1° and 21-45°. For the mesiobuccal-palatal angle groups, a higher prevalence of the MSF Type II relationship was found in the <21° and >45° angle groups, and a higher prevalence of the Type I relationship was found in the 21-45° angle group. For the distobuccal-palatal angle groups, higher percentages of the MSF Type II relationship were found in the three angle groups. For all teeth, there was a significant positive correlation between the MSF vertical relationship and the mesiobuccal-palatal angle (r = 0.116; P = 0.039). CONCLUSION: There was a positive correlation between the divergence angle of the roots and their vertical relationship with the MSF. Clinicians should assess the divergence between the roots before performing extraction or endodontic treatments.

10.
Materials (Basel) ; 14(24)2021 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-34947142

RESUMEN

Conventional osteotomy techniques can, in some cases, induce higher stress on bone during implant insertion as a result of higher torque. The aim of the present study was to evaluate and compare the stress exerted on the underlying osseous tissues during the insertion of a tapered implant using different osteotomy techniques through a dynamic finite element analysis which has been widely applied to study biomedical problems through computer-aided software. In three different types of osteotomy techniques, namely conventional (B1), bone tap (B2), and countersink (B3), five models and implants designed per technique were prepared, implant insertion was simulated, and stress exerted by the implant during each was evaluated. Comparison of stress scores on the cortical and cancellous bone at different time points and time intervals from initiation of insertion to the final placement of the implant was made. There was a highly statistically significant difference between B1 and B2 (p = 0.0001) and B2 and B3 (p = 0.0001) groups. In contrast, there was no statistically significant difference in the stress scores between B1 and B3 (p = 0.3080) groups at all time points of implant placement. Overall, a highly significant difference was observed between the stresses exerted in each technique. Within the limitations of our study, bone tap significantly exerted lesser stresses on the entire bone than conventional and countersink type of osteotomy procedures. Considering the stress distribution at the crestal region, the countersink showed lower values in comparison to others.

11.
Photodiagnosis Photodyn Ther ; 36: 102515, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34469796

RESUMEN

AIM: The present study aimed to evaluate the effect of different cleansers and photodynamic therapy (PDT) on disinfection of Co/Cr removable partial denture colonized with C. albicans, S.aureus and S.mutans. MATERIAL AND METHODS: Twenty-five Co/Cr removable partial dentures were constructed. and inoculated by American Type Culture Collection (ATCC) of Candida albicans, S.aureus, and S.mutans in an in-vitro setup. Co/Cr removable partial dentures were randomly allocated into five groups and framework was immersed in 15 mL of contaminated culture medium broth. Based on the cleansing method, disinfected dentures in group 1 were cleansed with porphyrin derivative; group 2 was exposed to 0.12% chlorhexidine digluconate; samples in group 3 and group 4 were subjected to sodium perborate enzyme and citric acid respectively. Through a surface analyzer, the surface roughness of Co/Cr and methacrylate resin was measured in 3 different zones in micrometers before and after disinfection. Two-way ANOVA and Tukey's test was used to analyze the data. Levene test was used to assess the normal distribution of data. Significance level p< 0.05 RESULTS: The results of metal roughness displayed that Co/Cr used as an alloy did not exhibit significant difference when exposed to different chemical disinfectants and photosensitizer (p > 0.05). Similarly, surface roughness (Ra) of heat polymerized acrylic resin using cleansers and PDT demonstrated no significant difference. Intergroup comparison showed that, hematoporphyrin derivative displayed comparable cleansing property against S. aureus, C.albicans, and S. mutans compared to to 0.12% CHX digluconate (p>0.05). The intragroup comparison showed hematoporphyrin derivative and CHX were equally effective against all bacteria (p>0.05). CONCLUSION: CHX digluconate and hematoporphyrin derivative demonstrated high antimicrobial activity against S.aureus, S.mutans, and C.albicans with minimum Ra of an acrylic denture and Co/Cr metallic framework.


Asunto(s)
Dentadura Parcial Removible , Fotoquimioterapia , Porfirinas , Clorhexidina/farmacología , Aleaciones de Cromo , Dentaduras , Desinfección , Ensayo de Materiales , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/farmacología , Staphylococcus aureus
12.
Photodiagnosis Photodyn Ther ; 35: 102362, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34062305

RESUMEN

AIM: The study aimed to assess the effect of in-vitro chlorhexidine and antimicrobial photodynamic therapy (aPDT) disinfection protocols against acrylic resin specimens colonized with S. mutans, S. aureus, E. coli, and C. albicans. MATERIAL AND METHODS: Reference strains of S. mutans, S. aureus, E. coli, and C. albicans were tested. Sixteen blocks of acrylic specimens were prepared by heat-cure acrylic resin and contaminated by in-vitro biofilm growth. Specimens in group 1, group 2 and group 3 were treated with Rose Bengal (RB), methylene blue (MB) 500 mg/L and porphyrin derivative (PD) 5 ml respectively, for the sensitization of biofilms. All photosensitizers (PS) were activated by LED at different wavelength. CHX was prepared in sterile distilled water and applied for 60 s. Each contaminated specimen was sprayed on all its surfaces with the aforementioned photosensitizers and control CHX. One-way analysis of variance (ANOVA) model was used to test the effect of the treatments and Tukey multiple comparison tests to compare means OF CFU/mL (log10) for exposed E. coli, C. albicans, S aureus, and S. mutans RESULTS: Specimens treated with 0.12% CHX (control) demonstrated a significant reduction in CFU/mL (log10) for exposed E. coli; 2.04±0.07 CFU/mL, C. albicans; 2.09±0.85 CFU/mL, S aureus; 3.04±0.11 CFU/mL, and S. mutans; 2.54±0.91 CFU/mL. The intragroup comparison revealed E.coli did not exhibit a decrease in reduction CFU/mL (log10) when acrylic resin irradiated with RB 5 µm. Whereas, CFU/mL (log10) values of S.aureus; 3.62±0.68 and S.mutans; 3.41±0.13 plummeted (p<0.05). Intergroup comparison showed E.coli values to display comparable reduction when disinfected with MB 500 mg/L and 0.12% CHX; 3.16±0.34 and 2.04±0.07 CFU/mL (log10) (p<0.05). CONCLUSION: Photosensitizers (RB, MB, PD) are selective in reducing bacterial count on acrylic resin blocks. CHX was found to be effective against all bacteria E.coli, C.albicans, S.aureus, and S.mutans at a concentration of 0.12%.


Asunto(s)
Fotoquimioterapia , Porfirinas , Resinas Acrílicas , Biopelículas , Dentaduras , Desinfección , Escherichia coli , Azul de Metileno/farmacología , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/farmacología , Polímeros , Rosa Bengala/farmacología , Staphylococcus aureus , Streptococcus mutans
13.
Photodiagnosis Photodyn Ther ; 34: 102341, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33992812

RESUMEN

OBJECTIVE: The aim was to compare Photodynamic therapy (PDT) as an adjunct to NaOCl and EDTA on the extrusion bond strength (EBS) of AH Plus (AH), Sealapex (SA) and MTA Fillapex (MF) root canal sealers. MATERIALS AND METHOD: Root canal treatment for human teeth (n = 60) using protaper universal system was performed followed by irrigation with NaOCl/ EDTA. Samples were divided (n = 30) based on disinfection technique, NaOCl/EDTA and NaOCl/EDTA with PDT (Curcumin-PS-CP) as an adjunct. Specimens were divided in three subgroups (n = 10) based on sealers used (Gp 1-Na-E-AH, Gp 2-Na-E-PDT-AH, Gp 3-Na-E-SA, Gp 4-Na-E-PDT-SA, Gp 5-Na-E-MF & Gp 6-Na-E-PDT-MF). Canals were dried and obturated followed by sectioning at coronal and middle third. EBS testing was performed using a universal testing machine (UTM) and modes of failure were assessed. Analysis of variance (ANOVA) and Tukey multiple comparison tests were used to compare the means of EBS. (p < 0.05). RESULTS: Sealers showed a significant influence on EBS, as Gp 1 (Co: 9.21 ± 0.62, Mid: 8.54 ± 0.55) and Gp 2 (Co: 7.11 ± 0.68, Mid: 7.30 ± 0.37) showed higher EBS than Gp 3 (Co: 5.21 ± 0.63, Mid: 4.36 ± 0.83) and Gp 4 (Co: 5.39 ± 0.72, Mid: 4.46 ± 0.74). Gp 5 (Co: 9.04 ± 0.13, Mid: 8.14 ± 0.91) and Gp 6 (Co: 8.67 ± 0.42, Mid: 8.07 ± 0.07) exhibited higher EBS than Gp 3 and Gp 4 specimens. Adjunctive use of PDT for AH sealer (Gp 2) showed decreased EBS compared to Gp 1 specimens. EBS remained comparable for both MTA-Fillapex and Sealapex with and without PDT. CONCLUSION: AH Plus (Gp 1 and 2) and MTA-Fillapex (Gp 5 and 6) sealers displayed better EBS compared to Sealapex (Group 3 and 4). Adjunctive Application of PDT (CP) did not show a significant improvement in bond strength of sealers to root dentin.


Asunto(s)
Curcumina , Fotoquimioterapia , Curcumina/farmacología , Cavidad Pulpar , Dentina , Humanos , Ensayo de Materiales , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/farmacología , Preparación del Conducto Radicular
14.
Artículo en Inglés | MEDLINE | ID: mdl-33800420

RESUMEN

Dental laboratories (LABs) are integral to the performance of a dentist in providing successful oral rehabilitation. The aim of this study was to compare the adaptation, contour, contacts, and shade matching of different government and commercial dental LABs in the fabrication of porcelain fused to metal (PFM) crowns. Thirty-two dental LABs were selected to fabricate PFM crowns (one PFM crown each). Marginal adaptation, contour, proximal contacts, and shade matching were evaluated. Evaluation of the crowns' quality was performed following modified USPHS/FDI criteria. Visual and colorimeter assessments were employed to evaluate shade matching. Differences between groups were examined by Pearson's Chi-square and Fisher's exact test. The quality of marginal adaptation of crowns was good in 81.25%, however the quality of contours, contacts, and shade matching was compromised in 43.75%, 59.38%, and 39% of all LABs, respectively. Visual and colorimeter shade matching was acceptable in 62.5% and 80% of LABs in the cervical third and middle third regions of crowns, respectively, however in the incisal third the shade matching was unacceptable in nearly 60% of LABs. Commercial laboratories showed significantly better contours and shade matching, but not marginal adaptation. However, no significant differences were found in comparison of proximal contacts between the groups.


Asunto(s)
Porcelana Dental , Diente , Color , Coronas , Laboratorios Odontológicos
15.
Children (Basel) ; 8(3)2021 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-33805733

RESUMEN

Aim: This study aimed to investigate an association between dental caries status and anthropometric measures in primary school children. Methods and Materials: An analytical cross-sectional study (n = 376) was conducted among primary school children (age range = 6-9 years) registered in private schools. Non-clinical data was gathered from parents of participating children through a self-administered structured questionnaire as well as from the children through an interviewer-administered questionnaire. Clinical data included the examination of dental caries using dmft/DMFT index and anthropometric measures including calculated z-scores of height-for-age (HAZ), weight-for-age (WAZ), BMI-for-age (BAZ), and physical examination. Inferential statistics included Kruskal Wallis and linear regression for univariate and multivariate analysis respectively. Results: The proportion of dental caries in primary and secondary dentition was 67.6% and 8.2% respectively. A significant association was observed between dental caries status and HAZ, WAZ, and BAZ (p < 0.001). An inverse relation was found between low, medium, and high dental caries categories and anthropometric measures. Conclusions: In the primary dentition, dental caries were significantly and inversely related to weight-for-age, height-for-age, and BMI-for-age. Hence, it can be concluded that among the low-income population dental caries is associated with lower anthropometric outcomes in children and therefore caries management should be considered an approach impacting overall health and quality of life.

16.
J Pharm Bioallied Sci ; 13(Suppl 2): S1093-S1097, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35017936

RESUMEN

AIM: The aim of the study was to investigate whether the surface geometry or topography of implant abutments affects the retentive strength of prosthesis cemented with zinc phosphate on standard machined, sandblasted, and grooved implant abutments and to compare the results between them. MATERIALS AND METHODS: Fifteen similarly shaped implant abutments (MDcpk61; MIS Implant Technologies Ltd.,) (height 6.0 mm and 6-degree taper) were divided into three groups (n = 05): Group I - standard machined abutments without grooves, Group II - sandblasted abutments (same as Group I but sandblasted with 50 µ aluminum oxide), and Group III - abutment with prefabricated circumferential grooves. Further in these groups of 15 abutments, 5 abutments each are to be taken to check the retentive force of zinc phosphate cement. Fifteen identical cast copings was prepared to fit all 15 abutments. The castings will be cemented to each group of abutments with an above-mentioned luting agent. After thermal cycling and storage for 6 days in a water bath, a retention test is to be done with a tensile testing machine (Instron) (5 mm/min) and retentive forces will be recorded. Data will be subjected to one-way ANOVA test and Student's t-test. RESULTS: For zinc phosphate cement, F = 30.53 (>3.59 for P = 0.05) shows a statistically significant difference between all the three groups. CONCLUSION: Circumferential grooves on implant abutments give better retention when compared with standard machined (plain) and sandblasted abutments despite marked difference. CLINICAL SIGNIFICANCE: Retention of restoration depends on the surface of the abutment as well as the luting agents used. Incorporation of retentive grooves can enhance retention of prosthesis, especially in situation of short abutments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA