Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cureus ; 16(8): e66922, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39280516

RESUMEN

A persistent stapedial artery (PSA) is a rare embryologic remnant that typically involutes at week 10 of embryogenesis. However, if it is persistent, it may lead to conductive hearing loss and pulsatile tinnitus. It is of utmost importance to identify such an anomaly, as it leads to serious complications intraoperatively if overlooked. Proper clinical and radiological assessment helps an otologist recognize the PSA. We describe the case of a 24-year-old female presenting with a chronically discharging ear in addition to pulsatile tinnitus and conductive hearing loss with an incidental finding of a PSA upon otoscopy.

2.
J Int Adv Otol ; 20(2): 108-112, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-39155857

RESUMEN

Cochlear size variation was first reported in 1884, and since then, there have been various reports confirming the same. Yet, there is no single report that has displayed the wide variations in the cochlear size in a single layout capturing the cochlea in the oblique coronal view/ cochlear view. Basal turn diameter (A-value) was measured in the oblique coronal plane using the OTOPLAN® otological preplanning tool in 104 computed tomography (CT) scans of the temporal bones of cochlear implant (CI) recipients in a tertiary CI center. All CT scans with an image resolution of at least 0.5 mm and identified as having cochleae with normal anatomy were included in this study. A 3-dimensional (3D) segmentation was performed using the 3D slicer and visualized to evaluate the impact of cochlear size on the number of turns studied. The A-value was found to vary between 7.3 mm and 10.4 mm among the studied patients. Three-dimensional segmentation of the inner ear revealed only 2 turns of the cochlea in 4 ears, with A-values of 7.3, 8.8, 7.8, and 7.7 mm. One ear had only 11 /2 turns of the cochlea, with an A-value of 7.9 mm. As a further advancement in the assessment of cochlear size as determined by the A-value, 3D segmentation of the complete inner ear provides a full picture of the number of cochlear turns. Three-dimensional segmentation of the entire inner ear could help improve the preoperative planning of CI surgery and have implications for electrode array selection. Cochlear size could be a predictor of the number of cochlear turns, even in cases that look normal from the radiological findings. The findings of this study could help in improving the preoperative planning for a more successful CI surgery by differentiating between the normal and abnormal cochlea.


Asunto(s)
Cóclea , Implantación Coclear , Imagenología Tridimensional , Hueso Temporal , Tomografía Computarizada por Rayos X , Humanos , Implantación Coclear/métodos , Cóclea/diagnóstico por imagen , Cóclea/anomalías , Cóclea/anatomía & histología , Tomografía Computarizada por Rayos X/métodos , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/anatomía & histología , Masculino , Femenino , Imagenología Tridimensional/métodos , Persona de Mediana Edad , Implantes Cocleares , Anciano , Adulto , Estudios Retrospectivos , Tamaño de los Órganos , Adolescente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA