Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 12841, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38834703

RESUMEN

Organic-inorganic hybrid light-emitting devices have garnered significant attention in the last few years due to their potential. These devices integrate the superior electron mobility of inorganic semiconductors with the remarkable optoelectronic characteristics of organic semiconductors. The inquiry focused on analyzing the optical and electrical properties of a light-emitting heterojunction that combines p-type GaN with organic materials (PEDOT, PSS, and PMMA). This heterojunction is an organic-inorganic hybrid. The procedure entailed utilizing a spin-coating technique to apply a layer of either poly(methyl methacrylate) (PMMA) or a mixture of PMMA and poly(3,4ethylenedioxythiophene)-poly(styrene sulfonate) (PEDOT: PSS) onto an indium tin oxide (ITO) substrate. Subsequently, different Nd:YAG laser pulses (200, 250, and 300 pulses) were used to administer a GaN inorganic layer onto the prepared organic layer using a pulsed laser deposition approach. Subsequently, the thermal evaporation technique was employed to deposit an aluminum electrode on the top of the organic and inorganic layers, while laser pulses were fine-tuned for optimal performance. The Hall effect investigation verifies the p-type conductivity of the GaN material. The electroluminescence studies confirmed the production of blue light by the GaN-based devices throughout a range of voltage situations, spanning from 45 to 72 V.

2.
J Ultrasound ; 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38324099

RESUMEN

PURPOSE: Graphene-polymer nanocomposites significantly impact dental filler and antibacterial applications. The study aims to overcome some problems dental filers present and improve their properties and antibacterial activity. Synthesis graphene oxide (GO) and poly (methyl methacrylate) (PMMA) were used to reinforce two types of commercial hybrid/nano-dental fillings. METHODS: Developed acoustic-solution-sonication-casting methods were applied to fabricate the new graphene-polymer-dental filler nanocomposites. The structure, morphology, rheological and mechanical properties, and antibacterial of the newly fabricated filling-PMMA/ GO nanocomposites were investigated. RESULTS: Fourier transform infrared (FTIR) showed a significant interaction between the filling and the additional materials. The X-ray diffraction (XRD) analysis revealed a considerable change in crystalline behavior. Optical microscope (OM) with field emission scanning electron microscopy (FESEM) pictures demonstrated a substantial change in the morphology of the samples with a homogeneous and fine dispersion of the nanomaterials in the filler matrix. Multi-frequency ultrasound mechanical properties measured the ultrasonic velocity, absorption coefficient, compressibility, bulk modulus, and other mechanical properties that notably enhanced after GO contributed up to 325% of the ultrasonic absorption coefficient compared with hybrid/nano-fillers. Rheological properties were measured as viscosity, absorption coefficient, and specific viscosity, which significantly improved after adding PMMA and incorporating GO up to 57% of the viscosity, compared with hybrid/nano-fillers. The inhibition zone of moth bacteria, such as Enterococcus faecalis and E. staph bacteria, improved after the contribution of GO nanosheets up to 46%. CONCLUSION: Nanofillers nanocomposites presented better properties and inhabitances zone diameter of antibacterial.

3.
Sci Rep ; 13(1): 5680, 2023 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-37029253

RESUMEN

In the last few decays, the fiber-optic was employed in the field of sensing because of its benefits in contrast to other types of sensors such as small size, easy to fabricate, high response, and flexibility. In this study, unclad single mode fiber-optic sensor is proposed to operate at 650 nm wavelength. COMSOL Multiphysics 5.1 finite element method (FEM) is used to design the sensor and tested it theoretically. The middle portion of the fiber cladding is removed and replaced by gold nanoparticles (Au NPs) of 50 nm thickness. Analytic layer of 3 µm thickness was immersed in different liquids in range of refractive index (RI) from 1.000281 to 1.39. These liquids are NaCl Deionized (DI) water solution, sucrose-Deionized (DI) water solution, and glycerol solution Deionized (DI) water. It was found that the highest obtained sensitivity and resolution are for glycerol-DI water solution with value of 3157.98 (nm/RIU) and 3.16 × 10-5 (RIU), respectively. Furthermore, it is easy to fabricate and of low cost. In experiments, pulsed laser ablation (PLA) was used to prepare Au NPs. X-ray diffraction (XRD) shown that the peak of the intensity grew as the ablated energy increased as well as the structure crystallization. Transmission electron microscopy (TEM) revealed an average diameter of 30 nm at the three ablated energies, while X-ray spectroscopy (EDX) spectrum has indicated the presence of Au NPs in the prepared solution. The photoluminescence (PL) and ultraviolet-visible UV-Vis transmission were used to study the optical properties of the prepared Au NPs. An optical spectrum analyzer was used to obtain the sensor's output results. It has shown that best intensity was obtained for sucrose which confined with theoretical results.

4.
Appl Opt ; 61(21): 6257-6267, 2022 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-36256240

RESUMEN

This study proposed an unclad optical fiber biosensor based on the localized surface plasmon resonance phenomenon and operating at 650 nm using COMSOL Multiphysics 5.1 finite element method (FEM). Gold nanoparticles (50 nm thickness) were coated on the middle portion of the unclad fiber. Air, water, blood plasma, liver tissue, colon tissue, and pentanol (C5H11OH) were used as analytical layers with 3 µm. The sensor serves as a theoretical foundation for experimental research. The blood plasma had the highest sensitivity with a sensitivity of 10,638.297 nm/RIU and a resolution of 9.410-6RIU. The proposed sensor is a promising candidate for a low-cost, simple-geometry biochemical sensing solution.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Resonancia por Plasmón de Superficie/métodos , Oro , Pentanoles , Análisis de Elementos Finitos , Técnicas Biosensibles/métodos , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA