Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Endod ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39089614

RESUMEN

INTRODUCTION: This study aimed to compare a new multicolored rotary system with four heat-treated rotary instruments using the multimethod approach. METHODS: Three-hundred instruments of RCS Rainbow, Rotate, RaCe EVO, OneCurve, and ProTaper Ultimate systems were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy, and mechanical performance (cyclic fatigue, torsional resistance, bending and buckling resistance, and cutting ability). Unprepared surfaces after canal preparation of maxillary molars were evaluated using micro-computed tomography. Kruskal-Wallis and one-way analysis of variance post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments exhibited variations in active blade length, number of spirals, and cross-sectional designs. RCS Rainbow showed specific phase transformation temperatures, highest bending (400.5gf) and buckling (286gf) resistance values, and lowest mean angle of rotation (529°) (P < .05). OneCurve exhibited superior cutting ability (8.4 mm) and longer time to fracture (112s). RaCe EVO displayed the lowest time to fracture (51s), maximum torque (1.2 N.cm), buckling (174gf), and bending resistance (261gf) values (P < .05). ProTaper Ultimate showed the highest torque (1.6 N.cm) and angle of rotation (611°) (P < .05), while its bending load (262gf) was comparable to RaCe EVO (P > .05). Rotate instrument showed intermediate values in the mechanical tests. No difference was observed regarding the unprepared canal surfaces (P > .05) CONCLUSIONS: RCS Rainbow demonstrates a trade-off between flexibility and other mechanical properties. Its dimensions exceeded those of other instruments, affording it higher torque resistance, yet concurrently reducing its flexibility, angle of rotation, and cutting ability. OneCurve stands out as a well-balanced choice by integrating geometric design and mechanical performance.

2.
Int Endod J ; 57(5): 601-616, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38376108

RESUMEN

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Asunto(s)
Instrumentos Dentales , Titanio , Estudios Transversales , Diseño de Equipo , Ensayo de Materiales , Estrés Mecánico , Titanio/química , Preparación del Conducto Radicular , Metalurgia
3.
Int Endod J ; 56(11): 1412-1428, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37698946

RESUMEN

AIM: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS: Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.


Asunto(s)
Instrumentos Dentales , Calor , Diseño de Equipo , Estrés Mecánico , Preparación del Conducto Radicular , Titanio/química , Metalurgia , Oro , Ensayo de Materiales
4.
Int Endod J ; 56(6): 775-785, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36942476

RESUMEN

AIM: This study aimed to compare three rotary instruments produced by the EDM process with the heat-treated ProTaper Gold system regarding design, metallurgy, mechanical properties and shaping ability. METHODOLOGY: HyFlex EDM (25/~), Neoniti (25/.06), EDMax (25/.06) and ProTaper Gold (25/.08v) instruments (n = 58 per group) were compared regarding design, metallurgy and mechanical performance. Unprepared canal areas were calculated for each system after preparation of mesiobuccal, mesiolingual and distal canals of mandibular molars (15 canals per group) using micro-CT technology. Statistical analyses were performed using One-way anova post-hoc Tukey and Kruskal-Wallis post-hoc Dunn's tests (α = 5%). RESULTS: All instruments had asymmetrical blades, no radial lands, no major defects and almost equiatomic nickel/titanium ratios, but different cross-section designs, tip geometries and surface appearances. Although instruments had distinct transformation temperature curves, they showed crystallographic martensitic arrangement at 21°C and mixed austenite plus R-phase at body temperature. Neoniti and HyFlex EDM showed similar results in all mechanical tests (p > .05), while EDMax and ProTaper Gold had similar time to fracture (p = .841), maximum bending load (p = .729), and cutting ability (p = .985). ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mean percentages of unprepared canal areas ranged from 20.4% to 25.7% in the mesial canals, and from 20.8% to 26.2% in the distal canal, with no statistical differences among systems (p > .05). CONCLUSIONS: Instruments' geometry and phase transformation temperatures influenced the results of the mechanical tests, but not their shaping ability.


Asunto(s)
Preparación del Conducto Radicular , Humanos , Aleaciones Dentales/química , Instrumentos Dentales , Diseño de Equipo , Ensayo de Materiales , Temperatura , Titanio/química , Torque
5.
Clin Oral Investig ; 27(5): 2427-2436, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36749411

RESUMEN

OBJECTIVE: This study aimed to compare 3 reciprocating systems regarding design, metallurgy, mechanical properties, and shaping ability. MATERIALS AND METHODS: New Reciproc Blue R25, WaveOne Gold Primary, and REX 25 instruments (n=41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin, and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. Results were compared using one-way ANOVA post hoc Tukey and Kruskal-Wallis tests with a significant level set at 5%. RESULTS: All instruments showed symmetrical cross sections with asymmetrical blades, no radial lands, no major defects, and an almost equiatomic nickel and titanium ratio. The highest R-phase start temperatures were observed with WaveOne Gold (46.1°C) and REX (44.8°C), while Reciproc Blue had the lowest R-phase start (34.5°C) and finish (20°C) temperatures. WaveOne Gold had the lowest time to fracture (169 s) and the highest maximum load (301.6 gf) (P <0.05). The maximum torque of Reciproc Blue (2.2 N.cm) and WaveOne Gold (2.1 N.cm) were similar (P >0.05), but lower than REX (2.6 N.cm) (P <0.05). No statistical differences were observed among instruments in the angle of rotation (P >0.05) and in the shaping ability in both mesial and distal canals (P >0.05). CONCLUSION: Although the overall design, temperature transition phases and mechanical behavior parameters were different among tested instruments, they were similar in terms of shaping ability. CLINICAL RELEVANCE: All tested heat-treated NiTi reciprocating systems showed similar shaping ability, without clinically significant errors.


Asunto(s)
Calor , Preparación del Conducto Radicular , Instrumentos Dentales , Diseño de Equipo , Titanio , Metalurgia , Ensayo de Materiales
6.
Int Endod J ; 56(4): 530-542, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36508297

RESUMEN

AIM: To compare design, metallurgy and mechanical performance of the ProTaper (PT) Ultimate system with instruments of similar dimensions from the ProGlider, PT Gold and PT Universal systems. METHODOLOGY: New PT Ultimate instruments (n = 248) were compared with instruments of similar dimensions from ProGlider (n = 31), PT Gold (n = 155) and PT Universal (n = 155) systems regarding their number of spirals, helical angle, blade symmetry, tip geometry, surface finishing, nickel/titanium ratio, phase transformation temperatures and mechanical performance. One-way anova and nonparametric Mood's median tests were used for statistical comparison (α = 5%). RESULTS: All instruments had symmetrical blades without radial lands or flat sides, similar surface finishing and an almost equiatomic nickel/titanium ratio, whilst the number of spirals, helical angles and the tip geometry were different. PT Ultimate instruments showed 3 distinct heat treatments that matched with the colour of their metal wire. Slider and ProGlider instruments had similar R-phase start (Rs) and R-phase finish (Rf) temperatures. SX, F1, F2, F3 and Shaper instruments showed equivalent heat treatments (Rs ~45.6°C and Rf ~28.3°C) that were similar to their PT Gold counterparts (Rs ~47.9°C and Rf ~28.2°C), but completely distinct to the PT Universal ones (Rs ~16.2°C and Rf ~-18.2°C). Amongst the PT Ultimate instruments, the lowest maximum torques were observed in the SX (0.44 N cm), Slider (0.45 N cm) and Shaper (0.60 N cm) instruments, whilst the highest was noted in the FXL (4.90 N cm). PT Ultimate Slider and ProGlider had similar torsional (~0.40 N cm) and bending loads (~145.0 gf) (p = 1.000), whilst the other PT Ultimate instruments showed statistically significantly lower maximum torque, higher angle of rotation and lower bending load (higher flexibility) than their counterparts of the PT Universal and PT Gold systems. CONCLUSIONS: The PT Ultimate system comprises instruments with 3 distinct heat treatments that showed similar phase transformation temperatures to their heat-treated analogues. PT Ultimate instruments presented lower torsional strength and superior flexibility than their counterparts, whilst maximum torque, angle of rotation and bending loads progressively increased with their sizes.


Asunto(s)
Níquel , Titanio , Calor , Falla de Equipo , Ensayo de Materiales , Aleaciones Dentales , Preparación del Conducto Radicular , Diseño de Equipo , Torsión Mecánica
7.
Materials (Basel) ; 15(15)2022 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-35955223

RESUMEN

This study aimed to compare three endodontic rotary systems. The new Genius Proflex (25/0.04), Vortex Blue (25/0.04), and TruNatomy (26/0.04v) instruments (n = 41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. The results were compared using one-way ANOVA, post hoc Tukey, and Kruskal−Wallis tests, with a significance level set at 5%. All instruments showed symmetrical cross-sections, with asymmetrical blades, no radial lands, no major defects, and almost equiatomic nickel−titanium ratios. Differences were noted in the number of blades, helical angles, cross-sectional design, and tip geometry. The Genius Proflex and the TruNatomy instruments had the highest and lowest R-phase start and finish temperatures, as well as the highest and lowest time and cycles to fracture (p < 0.05), respectively. The TruNatomy had the highest flexibility (p < 0.05), while no differences were observed between the Genius Proflex and the Vortex Blue (p > 0.05). No differences among tested systems were observed regarding the maximum torque, angle of rotation prior to fracture, and shaping ability (p > 0.05). The instruments showed similarities and differences in their design, metallurgy, and mechanical properties. However, their shaping ability was similar, without any clinically significant errors. Understanding these characteristics may help clinicians to make decisions regarding which instrument to choose for a particular clinical situation.

8.
Restor Dent Endod ; 46(3): e42, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34513648

RESUMEN

OBJECTIVES: This study aimed to analyze the main features of the 25 most-cited articles in minimally invasive access cavities. MATERIALS AND METHODS: An electronic search was conducted on the Clarivate Analytics' Web of Science 'All Databases' to identify the most-cited articles related to this topic. Citation counts were cross-matched with data from Elsevier's Scopus and Google Scholar. Information about authors, contributing institutions and countries, year and journal of publication, study design and topic, access cavity, and keywords were analyzed. RESULTS: The top 25 most-cited articles received a total of 572 (Web of Science), 1,160 (Google Scholar) and 631 (Scopus) citations. It was observed a positive significant association between the number of citations and age of publication (r = 0.6907, p < 0.0001); however, there was no significant association regarding citation density and age of publication (r = -0.2631, p = 0.2038). The Journal of Endodontics made the highest contribution (n = 15, 60%). The United States had the largest number of publications (n = 7) followed by Brazil (n = 4), with the most contributions from the University of Tennessee and Grande Rio University (n = 3), respectively. The highest number of most-cited articles were ex vivo studies (n = 16), and 'fracture resistance' was the major topic studied (n = 10). CONCLUSIONS: This study revealed a growing interest for researchers in the field of minimally invasive access cavities. Future trends are focused on the expansion of collaborative networks and the conduction of laboratory studies on under-investigated parameters.

9.
J Endod ; 40(9): 1400-3, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25043329

RESUMEN

INTRODUCTION: Interleukin (IL)-17 expression has been detected in apical periodontitis lesions, but its role in the disease process remains unclear. The present study compared the expression of IL-17 in periradicular cysts and granulomas and evaluated the association of this cytokine with clinical and radiographic findings. METHODS: Apical periodontitis lesions (18 cysts and 20 granulomas) were obtained from 38 patients subjected to periradicular surgery. Some clinical, radiographic, and cone-beam computed tomographic features were recorded. Silanized slides containing paraffin sections were used for the immunohistochemical reactions using anti-IL-17 antibody. Image analysis was performed using an optical microscope, and each sample was divided into 5 high-power fields, which were evaluated for the expression of IL-17 in the epithelium and connective tissues. Results were evaluated for correlations with the lesion size and the occurrence of symptoms and sinus tract. RESULTS: Expression of IL-17 was significantly higher in cysts than in granulomas (P = .02). Among the periradicular cysts, a thin epithelium showed significantly increased labeling for IL-17 when compared with a hyperplastic epithelium (P = .003). IL-17 expression was usually associated with focal accumulations of polymorphonuclear leukocytes. No association of IL-17 expression with symptoms, sinus tract, or lesion size was observed (P > .05). CONCLUSIONS: The present study reinforces the notion that IL-17 may take part in the pathogenesis of apical periodontitis lesions. A role in the exacerbation of chronic inflammation and cyst formation is suspected. Further studies are required to shed light on the specific functions of IL-17 in periradicular inflammatory processes.


Asunto(s)
Interleucina-17/análisis , Periodontitis Periapical/inmunología , Adulto , Tomografía Computarizada de Haz Cónico/métodos , Tejido Conectivo/inmunología , Tejido Conectivo/patología , Fístula Dental/inmunología , Fístula Dental/patología , Epitelio/inmunología , Epitelio/patología , Femenino , Humanos , Hiperplasia , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Neutrófilos/inmunología , Neutrófilos/patología , Granuloma Periapical/diagnóstico por imagen , Granuloma Periapical/inmunología , Granuloma Periapical/patología , Periodontitis Periapical/diagnóstico por imagen , Periodontitis Periapical/patología , Quiste Radicular/diagnóstico por imagen , Quiste Radicular/inmunología , Quiste Radicular/patología
10.
J Endod ; 39(4): 534-7, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23522552

RESUMEN

INTRODUCTION: This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files. METHODS: S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation. RESULTS: Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P < .05), except for PathFiles at the 0-mm level. ScoutRaCe instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P < .05). CONCLUSIONS: Findings suggest that rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance.


Asunto(s)
Instrumentos Dentales , Cavidad Pulpar/anatomía & histología , Preparación del Conducto Radicular/instrumentación , Análisis de Varianza , Aleaciones Dentales , Diseño de Equipo , Humanos , Imagenología Tridimensional , Modelos Dentales , Níquel , Preparación del Conducto Radicular/métodos , Acero Inoxidable , Titanio
11.
J Endod ; 39(2): 173-6, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23321226

RESUMEN

INTRODUCTION: The aim of this randomized, controlled, prospective clinical study was to determine if foraminal enlargement instrumentation during endodontic treatment is associated with more postoperative pain compared with standard nonenlargement instrumentation. METHODS: Forty volunteers with a single root canal were diagnosed with asymptomatic necrosis with apical periodontitis and randomized into 2 experimental groups (ie, the control group and the foraminal enlargement group). Endodontic treatment was performed in a single visit, and volunteers were instructed to record pain intensity (ie, none, slight, moderate, and severe). Scores from 1 to 4 were attributed to each kind of pain after 12, 24, and 48 hours. The Kolmogorov-Smirnov and Student's t tests were used to determine significant differences at P < .05. RESULTS: No statistically significant age difference was found between the groups (P > .05, Student's t test). Postoperative pain showed no statistically significant difference between the groups at any observation period (P > .05). Also, no significant difference was observed in the mean number of analgesic tablets used between the groups (P > .05). CONCLUSIONS: The foraminal enlargement and nonenlargement techniques resulted in the same postoperative pain and necessity for analgesic medication. This may suggest that the use of foraminal enlargement should be performed for endodontic treatment previsibility without increasing postoperative pain.


Asunto(s)
Cavidad Pulpar/cirugía , Necrosis de la Pulpa Dental/terapia , Dolor Postoperatorio/etiología , Periodontitis Periapical/terapia , Preparación del Conducto Radicular/métodos , Adulto , Antiinflamatorios no Esteroideos/uso terapéutico , Enfermedades Asintomáticas , Cavidad Pulpar/patología , Prueba de la Pulpa Dental , Femenino , Estudios de Seguimiento , Gutapercha/uso terapéutico , Humanos , Ibuprofeno/uso terapéutico , Masculino , Dimensión del Dolor , Estudios Prospectivos , Materiales de Obturación del Conducto Radicular/uso terapéutico , Irrigantes del Conducto Radicular/uso terapéutico , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación , Hipoclorito de Sodio/uso terapéutico , Ápice del Diente/patología
12.
Rev. bras. odontol ; 69(2): 255-257, Jul.-Dez. 2012. ilus
Artículo en Portugués | LILACS | ID: lil-720353

RESUMEN

O objetivo do presente estudo foi avaliar o efeito antimicrobiano do Paramonoclorofenol Canforado (PMCFC) e do Tricresol Formalina (TF) frente ao Enterococcus faecalis utilizando uma nova metodologia para simular a volatilização dos compostos. Enterococcus faecalis foram inoculados em placas de Petri com BHI, na qual foram fincados escalpes contendo algodão embebido em PMCFC e TF. Bolinhas de algodão sem medicação foram utilizadas como controle negativo. Após 48 horas de cultivo, foi avaliada a formação de halos de inibição de crescimento bacteriano. Pode-se constatar que o grupo com TF produziu halos de inibição em 100% dos escalpes, enquanto o PMCFC e o controle negativo não produziram halo de inibição. Conclui-se que somente o TF apresentou atividade antimicrobiana por volatilização.


The aim of the present study was to evaluate the antimicrobial effects of paramonochlorophenol and tricresol formalin using a new methodology to simulate the volatilization of these substances. Enterococcus faecalis were inoculated em petri dishes with BHI and mm scalps containing cotton balls soaked with the tested substances were stucked in the petri dishes. Cotton balls without medication were used as negative control. After 48 hours the inhibition halo formation was evaluated. The results showed that tricresol formalin group presented inhinition zones in 100% of scalps, while paramochlorophenol and control group produced no inhibition zone. The results suggested that the vapor of formalin tricresol has antibacterial activity; however paramonochlorophenol was unable to exert antibacterial activity from the volatilization of its gases.


Asunto(s)
Irrigantes del Conducto Radicular , Endodoncia , Microbiota
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA