Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Polymers (Basel) ; 15(5)2023 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-36904337

RESUMEN

PLA and its blends are the most extensively used materials for various biomedical applications such as scaffolds, implants, and other medical devices. The most extensively used method for tubular scaffold fabrication is by using the extrusion process. However, PLA scaffolds show limitations such as low mechanical strength as compared to metallic scaffolds and inferior bioactivities, limiting their clinical application. Thus, in order to improve the mechanical properties of tubular scaffolds, they were biaxially expanded, wherein the bioactivity can be improved by surface modifications using UV treatment. However, detailed studies are needed to study the effect of UV irradiation on the surface properties of biaxially expanded scaffolds. In this work, tubular scaffolds were fabricated using a novel single-step biaxial expansion process, and the surface properties of the tubular scaffolds after different durations of UV irradiation were evaluated. The results show that changes in the surface wettability of scaffolds were observed after 2 min of UV exposure, and wettability increased with the increased duration of UV exposure. FTIR and XPS results were in conjunction and showed the formation of oxygen-rich functional groups with the increased UV irradiation of the surface. AFM showed increased surface roughness with the increase in UV duration. However, it was observed that scaffold crystallinity first increased and then decreased with the UV exposure. This study provides a new and detailed insight into the surface modification of the PLA scaffolds using UV exposure.

2.
Acta Histochem ; 122(7): 151615, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33066837

RESUMEN

Modification of Polylactic acid (PLA), a biopolymer, is a strategy still to be fully explored for the next generation of bioresorbable vascular stent (BVS) biomaterials. With this focus, inclusions upto 5% of Polycaprolactone (PCL) and Magnesium in PLA were tested in the rat subcutaneous model and their cellular and tissue interactions characterized, specifically with respect to inflammatory response, angiogenesis and capsularization. The cytokines IL6, TNF Alpha and IL-1Beta were estimated in the peri-implant tissue, all of which showed a non-significant difference between the non-implanted animals and those containing PLA by 8 weeks, speaking to the benign nature of PLA as an implant biomaterial. Both modified materials, had increased macrophage counts and cytokine levels, except IL6 at 8 weeks. Vascularization only at 8 weeks in PLA PCL containing tissue was significantly higher than pure PLA, which may be more carefully controlled along with the material hydrophobicity for possible efforts towards therapeutic angiogenesis. Capsule thickness, measured by staining with both Hematoxylin & Eosin and Masson's Trichome did not show any differences between materials, including PLA.


Asunto(s)
Materiales Biocompatibles , Poliésteres/efectos adversos , Stents , Andamios del Tejido , Animales , Materiales Biocompatibles/efectos adversos , Materiales Biocompatibles/metabolismo , Anomalías Cardiovasculares/cirugía , Poliésteres/metabolismo , Ratas , Andamios del Tejido/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA