Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38290999

RESUMEN

PURPOSE: When applied alone, titanium (Ti) mesh may not effectively block the penetration of soft tissues, resulting in insufficient new bone formation. This study aimed to confer bioactivity and improve bone regeneration by doping calcium phosphate (CaP) precipitation and strontium (Sr) ranelate onto a TiO2 nanotube (TNT) layer on the surface of a Ti mesh. METHODS: The TNT layer was obtained by anodizing on the Ti mesh, and CaP was formed by cyclic pre-calcification. The final specimens were produced by doping with Sr ranelate. The surface properties of the modified Ti mesh were investigated using high-resolution field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray diffraction. To evaluate the effects of surface treatment on cell viability, osteoblasts were cultured for 1-3 days, and their absorbance was subsequently measured. In an in vivo experiment, critical-size defects were created in rat calvaria (Ф=8 mm). After 5 weeks, the rats were sacrificed (n=4 per group) and bone blocks were taken for micro-computed tomography and histological analysis. RESULTS: After immersing the Sr ranelate-doped Ti mesh in simulated body fluid, the protrusions observed in the initial stage of hydroxyapatite were precipitated as a dense structure. On day 3 of osteoblast culture, cell viability was significantly higher on the pre-calcified Sr ranelate-doped Ti mesh surface than on the untreated Ti mesh surface (P<0.05). In the in vivo experiment, a bony bridge formed between the surrounding basal bone and the new bone under the Sr ranelate-doped Ti mesh implanted in a rat calvarial defect, closing the defect. New bone mineral density (0.91±0.003 g/mm3) and bone volume (29.35±2.082 mm3) significantly increased compared to the other groups (P<0.05). CONCLUSIONS: Cyclic pre-calcification of a Ti mesh with a uniform TNT layer increased bioactivity, and subsequent doping with Sr ranelate effectively improved bone regeneration in bone defects.

2.
Dent Mater J ; 39(2): 206-213, 2020 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-31694997

RESUMEN

The aim of this study was to evaluate the effects of the kinds of veneering ceramics and veneering methods on the debonding/crack initiation and 3-point flexural strengths in bilayered zirconia core and veneering ceramic composites. Zirconia block was used as core material, and Cerabien ZR and Lava Ceram for the layering technique and IPS e.max ZirPress and Amber LiSi-POZ for the heat pressing technique were used as veneering materials. Both debonding/crack initiation and 3-point flexural strengths of bilayered zirconia core and veneering ceramic composites as well as the bi-axial flexural strengths of veneering materials, were higher when using heat pressing technique than layering technique. It was identified that not only bonding strength between zirconia core and veneering materials but also the intrinsic strength of veneering ceramic should be high to prevent chipping of veneering material.


Asunto(s)
Porcelana Dental , Coronas con Frente Estético , Cerámica , Análisis del Estrés Dental , Resistencia Flexional , Ensayo de Materiales , Propiedades de Superficie , Circonio
3.
J Adv Prosthodont ; 7(5): 349-57, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26576250

RESUMEN

PURPOSE: The purpose of this study was to assess the impact of the core materials, thickness and fabrication methods of veneering porcelain on prosthesis fracture in the porcelain fused to metal and the porcelain veneered zirconia. MATERIALS AND METHODS: Forty nickel-chrome alloy cores and 40 zirconia cores were made. Half of each core group was 0.5 mm-in thickness and the other half was 1.0 mm-in thickness. Thus, there were four groups with 20 cores/group. Each group was divided into two subgroups with two different veneering methods (conventional powder/liquid layering technique and the heat-pressing technique). Tensile strength was measured using the biaxial flexural strength test based on the ISO standard 6872:2008 and Weibull analysis was conducted. Factors influencing fracture strength were analyzed through three-way ANOVA (α≤.05) and the influence of core thickness and veneering method in each core materials was assessed using two-way ANOVA (α≤.05). RESULTS: The biaxial flexural strength test showed that the fabrication method of veneering porcelain has the largest impact on the fracture strength followed by the core thickness and the core material. In the metal groups, both the core thickness and the fabrication method of the veneering porcelain significantly influenced on the fracture strength, while only the fabrication method affected the fracture strength in the zirconia groups. CONCLUSION: The fabrication method is more influential to the strength of a prosthesis compared to the core character determined by material and thickness of the core.

4.
J Adv Prosthodont ; 7(2): 172-7, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25932317

RESUMEN

PURPOSE: The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS: It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens (10×10×1.5 mm) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS: The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION: The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.

5.
Clin Oral Implants Res ; 26(6): 709-14, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24712313

RESUMEN

OBJECTIVES: The aim was to analyze influential factors and effects of proximal contact loss between implant-supported fixed dental prostheses (FDP) and adjacent teeth. MATERIAL AND METHODS: Ninety-four subjects treated with 135 FDPs supported by 188 implants were included. Degree of proximal contact tightness, food impaction, and periodontal/peri-implant tissue conditions were assessed in 191 proximal embrasures between implant-supported FDPs and adjacent teeth. Potential factors influencing proximal contact loss were estimated with the generalized estimation equation (GEE) procedure. RESULTS: Thirty-four percent of the proximal embrasures between implant-supported FDPs and teeth lost a proximal contact. The proximal contact loss rate continuously increased over the follow-up periods. A longer follow-up period, splinted implants, and mesial aspect of proximal contact were significant factors influencing the proximal contact loss in the univariate GEE analysis, whereas a longer follow-up period was the only significant factor in the multivariate GEE analysis. Food impaction was more frequently reported in the proximal contact loss group than the proximal contact group (odds ratio: 2.2). However, the proximal contact loss did not appear to affect the periodontal/peri-implant tissue conditions. CONCLUSIONS: Proximal contact loss between implant-supported FDPs and teeth occurred frequently and increased continuously over the follow-up period. The proximal contact loss significantly affected food impaction, but not the periodontal/peri-implant tissue conditions. Proximal contact loss should be carefully monitored during follow-up examinations in relation to food impaction.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija , Migración del Diente , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Pilares Dentales , Femenino , Humanos , Masculino , Persona de Mediana Edad
6.
J Adv Prosthodont ; 6(3): 241-4, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25006389

RESUMEN

Fabricating a crown to retrofit an existing abutment tooth for a partial removable dental prosthesis (PRDP) is one of the most time-consuming and labor-intensive clinical procedures. In particular, when the patient is concerned with esthetic aspects of restoration, the task of fabricating becomes more daunting. Many techniques for the fabrication of all-metallic or metal-ceramic crowns have been discussed in the literature. This article was aimed to describe a simple fabrication method in which a retrofitting crown was fabricated for a precise fit using a ceramic-pressed-to-metal system.

7.
J Adv Prosthodont ; 4(1): 52-6, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22439101

RESUMEN

Conventional implant protocols required a load-free healing period of three to six months between placement and functional loading of the implants. Many efforts have been made to minimize the duration of treatment time. Several literatures have documented immediate function with provisional or definitive prosthesis within a week of the placement in response to these demands. In addition, immediate implant placement has advantages such as shortened treatment time and preservation of soft tissue architectures. This article presents immediate implant placement into fresh extraction sockets followed by functional immediate loading with provisional prosthesis on canine and premolars for a patient having canine protected occlusion.

8.
J Adv Prosthodont ; 2(4): 128-33, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21264191

RESUMEN

PURPOSE: The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS: The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with 10° of mesial angulation to the center analog. Four types of impression coping were prepared with different combinations of types (transfer, pick-up) and lengths (long, short) of the coping. The impressions were made using vinyl polysiloxane (one step, heavy + light body) with an individual tray, and 10 impressions were made for each group. Eventually, 40 experimental casts were produced. Then, the difference in the distance between the master cast and the experimental cast were measured, and the error rate was determined. The analysis of variance was performed using the SPSS (v 12.0) program (α = .05), and the statistical significance was set at P < .05. RESULTS: The ANOVA showed that the pick-up type impression coping exhibited a significantly lower error rate than the transfer type. However, no significant difference was observed with respect to the length of the impression coping. Additionally, no significant difference was observed between the parallel and mesial angulated groups. CONCLUSION: Within the limitations of this study, the pick-up type impression coping exhibited a more accurate implant master cast than the transfer type in parallel group. The accuracy of the implant master cast did not differ for different lengths of impression coping of at least 11 mm. Additionally, the accuracy of the implant cast was not different for the parallel and 10° mesial angulated groups.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA