Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 377
Filtrar
1.
Magn Reson Med ; 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39221556

RESUMEN

PURPOSE: To propose a new method for quantitatively mapping the renal metabolic rate of oxygen (RMRO2) and to evaluate the proposed method using a caffeine challenge. THEORY AND METHODS: Pseudo-continuous arterial spin labeling (pCASL) and QSM sequences were used to obtain MR images in the kidney. Six healthy volunteers were scanned on caffeine and control days. The pCASL and QSM images were registered using DICOM information and rigid translation. The Fick principle was applied to estimate RMRO2. The results on caffeine and control days were compared to evaluate the capability of the proposed method to estimate renal oxygen consumption. A paired t-test was used to assess the statistical significance. RESULTS: Estimated renal blood flow (RBF), QSM, and RMRO2 maps were consistent with those reported in the literature. RMRO2 values were higher than the cerebral metabolic rate of oxygen (CMRO2) and were significantly reduced on the caffeine days compared to the control days, consistent with findings from non-MRI literature. CONCLUSION: The feasibility of measuring renal oxygen consumption using pCASL and QSM images was demonstrated. To the best of our knowledge, this work provides quantitative maps of renal oxygen consumption in humans for the first time. The results were consistent with the literature, including the statistically significant reduction in renal oxygen consumption with caffeine challenge. These findings suggest the potential utility of our technique in measuring renal oxygen consumption noninvasively, especially for patients with complications associated with contrast agents.

2.
Blood Adv ; 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39293078

RESUMEN

The pathogenesis of MYC and BCL2 double expressor diffuse large B-cell lymphoma (DE-DLBCL) remains unclear. To investigate how MYC and BCL2 contribute to tumor aggressiveness, we analyzed tumors from 14 patients each with DE- and non-DE-DLBCL patients by whole transcriptome sequencing. Validation was performed using publicly available datasets, tumor tissues from 126 patients, DLBCL cell lines, and a syngeneic mouse lymphoma model. Our transcriptome analysis revealed significantly elevated mRNA levels of C-C motif chemokine ligand 2 (CCL2) and C-C chemokine receptor type 2 (CCR2) in DE-DLBCLs compared to non-DE-DLBCLs (Padj < 0.05). Transcriptomic analysis with public datasets and immunohistochemistry corroborated these findings, indicating heightened M2 macrophage presence but diminished T-cell infiltration in DE-DLBCLs compared to non-DE-DLBCLs (all, P < 0.05). CCR2 expression was observed mainly in tumor-infiltrating macrophages rather than DLBCL cells. Increased CCL2 and CCR2 expression were significantly associated with the poor prognosis of patients with DLBCL. In vitro analyses, MYChigh/BCL2high DLBCL cells showed higher CCL2 expression and secretion than MYClow/BCL2low cells. MYC and BCL2 increased CCL2 expression and secretion by upregulation of nuclear factor-κB p65 in DLBCL cells and the CCL2 promoted M2 polarization of macrophages. In a mouse lymphoma model, CCL2 contributed to the immunosuppressive microenvironment and tumor growth of MYChigh/BCL2high tumor. We demonstrated that the increased CCL2/CCR2 axis confers aggressiveness to DE-DLBCL by increasing M2 polarization and can be a potential therapeutic target.

3.
Sci Adv ; 10(36): eadp5192, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39231222

RESUMEN

Light fields carry a wealth of information, including intensity, spectrum, and polarization. However, standard cameras capture only the intensity, disregarding other valuable information. While hyperspectral and polarimetric imaging systems capture spectral and polarization information, respectively, in addition to intensity, they are often bulky, slow, and costly. Here, we have developed an encoding metasurface paired with a neural network enabling a normal camera to acquire hyperspectro-polarimetric images from a single snapshot. Our experimental results demonstrate that this metasurface-enhanced camera can accurately resolve full-Stokes polarization across a broad spectral range (700 to 1150 nanometer) from a single snapshot, achieving a spectral sensitivity as high as 0.23 nanometer. In addition, our system captures full-Stokes hyperspectro-polarimetric video in real time at a rate of 28 frames per second, primarily limited by the camera's readout rate. Our encoding metasurface offers a compact, fast, and cost-effective solution for multidimensional imaging that effectively uses information within light fields.

4.
J Clin Monit Comput ; 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39158783

RESUMEN

PURPOSE: Intraoperative hypotension is associated with adverse outcomes. Predicting and proactively managing hypotension can reduce its incidence. Previously, hypotension prediction algorithms using artificial intelligence were developed for invasive arterial blood pressure monitors. This study tested whether routine non-invasive monitors could also predict intraoperative hypotension using deep learning algorithms. METHODS: An open-source database of non-cardiac surgery patients ( https://vitadb.net/dataset ) was used to develop the deep learning algorithm. The algorithm was validated using external data obtained from a tertiary Korean hospital. Intraoperative hypotension was defined as a systolic blood pressure less than 90 mmHg. The input data included five monitors: non-invasive blood pressure, electrocardiography, photoplethysmography, capnography, and bispectral index. The primary outcome was the performance of the deep learning model as assessed by the area under the receiver operating characteristic curve (AUROC). RESULTS: Data from 4754 and 421 patients were used for algorithm development and external validation, respectively. The fully connected model of Multi-head Attention architecture and the Globally Attentive Locally Recurrent model with Focal Loss function were able to predict intraoperative hypotension 5 min before its occurrence. The AUROC of the algorithm was 0.917 (95% confidence interval [CI], 0.915-0.918) for the original data and 0.833 (95% CI, 0.830-0.836) for the external validation data. Attention map, which quantified the contributions of each monitor, showed that our algorithm utilized data from each monitor with weights ranging from 8 to 22% for determining hypotension. CONCLUSIONS: A deep learning model utilizing multi-channel non-invasive monitors could predict intraoperative hypotension with high accuracy. Future prospective studies are needed to determine whether this model can assist clinicians in preventing hypotension in patients undergoing surgery with non-invasive monitoring.

5.
bioRxiv ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39026880

RESUMEN

Venous thrombosis (VT) is a common vascular disease associated with reduced survival and a high recurrence rate. Previous studies have shown that the accumulation of platelets and neutrophils at sites of endothelial cell activation is a primary event in VT, but a role for platelet αIIbß3 in the initiation of venous thrombosis has not been established. This task has been complicated by the increased bleeding linked to partial agonism of current αIIbß3 inhibitory drugs such as tirofiban (Aggrastat ® ). Here, we show that m-tirofiban, an engineered version of tirofiban, is not a partial agonist of αIIbß3. This is based on its cryo-EM structure in complex with human full-length αIIbß3 and its inability to increase expression of an activation-sensitive epitope on platelet αIIbß3. m-tirofiban abolished agonist-induced platelet aggregation ex vivo at concentrations that preserved clot retraction and markedly suppressed the accumulation of platelets, neutrophils, and fibrin on thrombin-activated endothelium in real-time using intravital microscopy in a mouse model of venous thrombogenesis. Unlike tirofiban, however, m-tirofiban did not increase bleeding at the thrombosis-inhibitory dose. These findings establish a key role for αIIbß3 in the initiation of VT, provide a guiding principle for designing potentially safer inhibitors for other integrins, and suggest that pure antagonists of αIIbß3 like m-tirofiban merit further consideration as potential thromboprophylaxis agents in patients at high-risk for VT and hemorrhage.

6.
Nanophotonics ; 13(17): 3147-3154, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39055568

RESUMEN

The metasurfaces have shown great potential for miniaturizing conventional optics while offering extended flexibility. Recently, there has been considerable interest in using algorithms to generate meta-atom shapes for these metasurfaces, as they offer vast design freedom and not biased by the human intuition. However, these complex designs significantly increase the difficulty of fabrication. To address this, we introduce a design process that rigorously enforces the fabricability of both the material-filled (fill) and empty (void) regions in a metasurface design. This process takes into account specific constraints regarding the minimum feature size for each region. Additionally, it corrects any violations of these constraints across the entire device, ensuring only minimal impact on performance. Our method provides a practical way to create metasurface designs that are easy to fabricate, even with complex shapes, hence improving the overall production yield of these advanced meta-optical components.

7.
Perioper Med (Lond) ; 13(1): 79, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39039548

RESUMEN

BACKGROUND: Surgery is the primary treatment for non-small cell lung cancer (NSCLC), but microscopic residual disease may be unavoidable. Preclinical studies have shown that volatile anesthetics might suppress host immunity and promote a pro-malignant environment that supports cancer cell proliferation, migration, and angiogenesis, whereas propofol may preserve cell-mediated immunity and inhibit tumor angiogenesis. However, clinical evidence that propofol-based total intravenous anesthesia (TIVA) can reduce tumor recurrence after curative resection remains inconsistent due to the retrospective observational nature of previous studies. Therefore, we will test the hypothesis that the recurrence-free survival (RFS) after curative resection of NSCLC is higher in patients who received TIVA than volatile anesthetics (GAS) in this multicenter randomized trial. METHODS: This double-blind, randomized trial will enroll patients at 22 international sites, subject to study registration, institutional review board approval, and patient written informed consent. Eligible patients are adult patients undergoing lung resection surgery with curative intent for NSCLC. Exclusion criteria will be contraindications to study drugs, American Society of Anesthesiologists physical status IV or higher, or preexisting distant metastasis or malignant tumor in other organs. At each study site, enrolled subjects will be randomly allocated into the TIVA and GAS groups with a 1:1 ratio. This pragmatic trial does not standardize any aspect of patient care. However, potential confounders will be balanced between the study arms. The primary outcome will be RFS. Secondary outcomes will be overall survival and complications within postoperative 7 days. Enrollment of 5384 patients will provide 80% power to detect a 3% treatment effect (hazard ratio of 0.83) at alpha 0.05 for RFS at 3 years. DISCUSSION: Confirmation of the study hypothesis would demonstrate that a relatively minor and low-cost alteration in anesthetic management has the potential to reduce cancer recurrence risk in NSCLC, an ultimately fatal complication. Rejection of the hypothesis would end the ongoing debate about the relationship between cancer recurrence and anesthetic management. TRIAL REGISTRATION: The study protocol was prospectively registered at the Clinical trials ( https://clinicaltrials.gov , NCT06330038, principal investigator: Hyun Joo Ahn; date of first public release: March 25, 2024) before the recruitment of the first participant.

8.
Perioper Med (Lond) ; 13(1): 56, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38877533

RESUMEN

BACKGROUND: Remimazolam is a short-acting benzodiazepine newly approved for the induction and maintenance of general anesthesia. Remimazolam emerges as an ideal drug for the neurosurgical population due to its rapid emergence, enabling early neurological assessment, and its ability to maintain perfusion pressure, which is crucial for preventing cerebral ischemia. However, the use of benzodiazepine has been associated with an increased risk of postoperative delirium (POD). There is currently limited evidence about the relationship between remimazolam-based total intravenous anesthesia (TIVA) and POD. METHODS: In this double-blind, randomized, non-inferiority trial, we plan to include 696 adult patients with American Society of Anesthesiologists physical status class I to III, undergoing elective neurovascular surgery under general anesthesia. After informed consent, the patients will be randomized to receive either remimazolam or propofol-based TIVA with a 1:1 ratio. The primary outcome is the incidence of POD within 5 days after surgery. Secondary outcomes include subtypes, number of positive assessments and severity of POD, emergence agitation, intraoperative awareness and undesirable patient movement, intraoperative hypotension, and postoperative cognitive function. The data will be analyzed in modified intention to treat. DISCUSSION: This trial will evaluate the effect of remimazolam on the development of POD compared to propofol anesthesia. The results of this trial will provide evidence regarding the choice of optimal anesthetics to minimize the risk of POD in neurosurgical patients. TRIAL REGISTRATION: The study protocol was prospectively registered at the Clinical trials ( https://clinicaltrials.gov , NCT06115031, principal investigator: Jiseon Jeong; date of first registration: November 2, 2023, before the recruitment of the first participant.

9.
ACS Appl Mater Interfaces ; 16(24): 31384-31391, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38855921

RESUMEN

Soft electronic materials hold great promise for advancing flexible functional devices. Among the various soft materials available, hydrogels are particularly attractive for soft electronic device development due to their inherent properties, including transparency, shape adaptability through swelling/deswelling, and self-healing capabilities. Transparent hydrogels contribute to the creation of advanced smart devices such as sensors, smart windows, and anticounterfeiting technologies. Poly(vinyl alcohol) hydrogels are used as a platform for creating electrofluorochromic (EFC) devices in combination with oligothiophene-conjugated benzothiazole derivatives (OCBs) as fluorescent emitters. OCBs demonstrated excited-state intramolecular proton transfer (ESIPT) behavior with a large Stokes shift and emission changes responsive to solvent polarity and pH stimuli. Even in the solid state, OCBs exhibited strong fluorescence emission across a wide range of colors from blue to red, making them exceptionally well-suited for EFC device development. Their quantum yields in the powder state were obtained between 2.3% and 19.9%. Through the incorporation of OCBs into a PVA hydrogel (OCB@PVA), we achieved the successful fabrication of flexible EFC devices, including electronic paper and smart panels. When electric potentials (-2.4 and +2.4 V) were applied in OCB@PVA, fluorescence color changes were observed by an electrochemically induced pH change owing to electrohydrolysis of water. These devices demonstrated the potential of OCB@PVA hydrogels in the realm of flexible electronics. They could be used to create innovative and versatile devices with stimuli-responsive fluorescence properties.

10.
J Anesth ; 38(5): 591-599, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38824469

RESUMEN

PURPOSE: Adequate oxygenation and airway management during deep sedation can be challenging. We investigated the effect of high-flow nasal cannula (group HF) and conventional nasal cannula (group CO) during sedation for endoscopic submucosal dissection (ESD). METHODS: Patients undergoing ESD with deep sedation were enrolled. The primary outcome was difference in lowest oxygen saturation (SpO2) between the groups. Incidence of hypoxia (SpO2 < 90%), patients with SpO2 < 95%, hypercapnia, and airway interventions; operator satisfaction; and adverse events were recorded. RESULTS: Thirty-two patients in each group completed the study. The mean of minimum SpO2 values was significantly higher in group HF than in group CO (96.8% ± 4.2% vs. 93.3% ± 5.3%, p = 0.005). The incidence of hypoxia was comparable between the groups (4 [12.5%] vs. 6 [18.8%], p = 0.491); however, patients with SpO2 < 95% were significantly less in group HF (5 [15.6%] vs. 18 [56.3%], p = 0.003). Incidence of hypercapnia was higher in group HF than in group CO (14 [46.7%] vs. 5 [16.7%], p = 0.013). Airway rescue interventions were significantly less common in group HF. Satisfaction of operators and post-procedural complications were comparable between the two groups. In multivariable analysis, group CO and higher body mass index were risk factors for airway managements (odds ratio [95% confidence interval]: 6.204 [1.784-21.575], p = 0.004; 1.337 [1.043-1.715], p = 0.022, respectively). CONCLUSIONS: Compared to conventional nasal cannula, high-flow nasal cannula maintained higher minimum SpO2 value during deep sedation with propofol-remifentanil for ESD. TRIAL REGISTRATION: Clinical Trial Registry of the Republic of Korea (KCT0006618, https://cris.nih.go.kr ; registered September 29, 2021; principal investigator: Ji Won Choi).


Asunto(s)
Cánula , Sedación Profunda , Resección Endoscópica de la Mucosa , Hipercapnia , Humanos , Masculino , Femenino , Sedación Profunda/métodos , Anciano , Persona de Mediana Edad , Resección Endoscópica de la Mucosa/métodos , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/instrumentación , Hipoxia/etiología , Hipoxia/prevención & control , Saturación de Oxígeno , Manejo de la Vía Aérea/métodos , Manejo de la Vía Aérea/instrumentación , Terapia por Inhalación de Oxígeno/métodos , Terapia por Inhalación de Oxígeno/instrumentación
11.
Anesth Pain Med (Seoul) ; 19(2): 94-108, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38725164

RESUMEN

Cancer is a leading cause of death worldwide. With the increasingly aging population, the number of emerging cancer cases is expected to increase markedly in the foreseeable future. Surgical resection with adjuvant therapy is the best available option for the potential cure of many solid tumors; thus, approximately 80% of patients with cancer undergo at least one surgical procedure during their disease. Agents used in general anesthesia can modulate cytokine release, transcription factors, and/or oncogenes. This can affect host immunity and the capability of cancer cells to survive and migrate, not only during surgery but for up to several weeks after surgery. However, it remains unknown whether exposure to anesthetic agents affects cancer recurrence or metastasis. This review explores the current literature to explain whether and how the choice of anesthetic and perioperative medication affect cancer surgery outcomes.

12.
ChemSusChem ; : e202400593, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38676292

RESUMEN

Recent advances in electrosynthesis of nanomaterials expanded structural and compositional variations accessible by the electrochemical method; however, reliably synthesizable morphological variety fall shy of that available by conventional solvothermal synthesis. In this communication, electrochemical preparation of surfactant-free hollow nanoparticles is demonstrated. By anodic conversion of core-shell precursors with metastable cores, hollowed nickel nanoparticles with uniform dimensions were synthesized and characterized. Implementation of TEM grids as the working electrodes, identical location tracking of the morphological evolution of single particles to anodic stimulus has been demonstrated. The synthesized nanoparticles were employed as catalysts for the alkaline hydrogen evolution reaction and exhibited catalytic rates that compare favorably to the Pt/C benchmark. This marks the first pure electrochemical synthesis of hollow nanoparticles and shall contribute to the structural diversification of electrosynthesized nanomaterials.

13.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38624037

RESUMEN

AIMS: Pulmonary vein isolation using cryoablation is effective and safe in patients with atrial fibrillation (AF). Although both obesity and underweight are associated with a higher risk for incident AF, there is limited data on the efficacy and safety following cryoablation according to body mass index (BMI) especially in Asians. METHODS AND RESULTS: Using the Korean Heart Rhythm Society Cryoablation registry, a multicentre registry of 12 tertiary hospitals, we analysed AF recurrence and procedure-related complications after cryoablation by BMI (kg/m2) groups (BMI < 18.5, underweight, UW; 18.5-23, normal, NW; 23-25, overweight, OW; 25-30, obese Ⅰ, OⅠ; ≥30, obese Ⅱ, OⅡ). A total of 2648 patients were included (median age 62.0 years; 76.7% men; 55.6% non-paroxysmal AF). Patients were categorized by BMI groups: 0.9% UW, 18.7% NW, 24.8% OW, 46.1% OI, and 9.4% OII. Underweight patients were the oldest and had least percentage of non-paroxysmal AF (33.3%). During a median follow-up of 1.7 years, atrial arrhythmia recurred in 874 (33.0%) patients (incidence rate, 18.9 per 100 person-years). After multivariable adjustment, the risk of AF recurrence was higher in UW group compared with NW group (adjusted hazard ratio, 95% confidence interval; 2.55, 1.18-5.50, P = 0.02). Procedure-related complications occurred in 123 (4.7%) patients, and the risk was higher for UW patients (odds ratio, 95% confidence interval; 2.90, 0.94-8.99, P = 0.07), mainly due to transient phrenic nerve palsy. CONCLUSION: Underweight patients showed a higher risk of AF recurrence after cryoablation compared with NW patients. Also, careful attention is needed on the occurrence of phrenic nerve palsy in UW patients.


Asunto(s)
Fibrilación Atrial , Índice de Masa Corporal , Criocirugía , Obesidad , Venas Pulmonares , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , República de Corea/epidemiología , Anciano , Resultado del Tratamiento , Factores de Riesgo , Venas Pulmonares/cirugía , Obesidad/complicaciones , Delgadez/complicaciones , Factores de Tiempo , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
14.
Chemistry ; 30(27): e202400191, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38498874

RESUMEN

Controlling the formation of photoexcited triplet states is critical for many (photo)chemical and physical applications. Here, we demonstrate that a permanent out-of-plane distortion of the benzothioxanthene imide (BTI) dye promotes intersystem crossing by increasing spin-orbit coupling. This manipulation was achieved through a subtle chemical modification, specifically the bay-area methylation. Consequently, this simple yet efficient approach expands the catalog of known molecular engineering strategies for synthesizing heavy atom-free, dual redox-active, yet still emissive and synthetically accessible photosensitizers.

15.
Can J Anaesth ; 71(5): 619-628, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38468077

RESUMEN

PURPOSE: Recently, endotracheal tubes with an embedded temperature sensor in the inner surface of the tube cuff (temperature tracheal tubes) have been developed. We sought to assess whether temperature tracheal tubes show a good agreement with esophageal temperature probes during surgery. METHODS: We enrolled 40 patients who underwent laparoscopic surgery in an observational study. The tracheas of all patients were intubated with a temperature tracheal tube, and an esophageal temperature probe was inserted into the esophagus. Tracheal and esophageal temperatures were recorded at 15-min intervals until the end of surgery. Temperatures from both devices were analyzed using Bland-Altman analysis, four-quadrant plots, and polar plots. RESULTS: We analyzed 261 data points from 36 patients. Temperatures ranges were 34.2 °C to 36.6 °C for the tracheal temperature tube and 34.7 °C to 37.2 °C for the esophageal temperature probe. Bland-Altman analysis showed an acceptable agreement between the two devices, with an overall mean bias (95% limit of agreement) of -0.3 °C (-0.8 °C to 0.1 °C) and a percentage error of 3%; the trending ability (temperature changes over time) between the two devices showed a concordance rate of 94% in four-quadrant plot (cut-off ≥ 92%), but this was higher than the acceptable mean angular bias of 177° (cut-off < ± 5°) and radial limits of agreement of 52° (cut-off < ± 30°) in the polar plot. Bronchoscopy during extubation and patient interviews at six hours postoperatively revealed no serious injuries related to the use of the temperature tracheal tube. CONCLUSION: The temperature tracheal tube showed an acceptable overall mean bias of -0.3 °C and a percentage error of 3%, but incompatible trending ability with the esophageal temperature probe. STUDY REGISTRATION: cris.nih.go.kr (KCT0007265); 22 April 2022.


RéSUMé: OBJECTIF: Récemment, des sondes endotrachéales munies d'un capteur de température intégré dans la surface interne du ballonnet de la sonde (sondes thermiques trachéales) ont été mises au point. Nous avons cherché à évaluer si les sondes trachéales de température montraient une bonne concordance avec les sondes thermiques œsophagiennes pendant la chirurgie. MéTHODE: Nous avons recruté 40 patient·es ayant bénéficié d'une chirurgie par laparoscopie dans le cadre d'une étude observationnelle. Les trachées de tou·tes les patient·es ont été intubées à l'aide d'une sonde trachéale de température et une sonde thermique œsophagienne a été insérée dans l'œsophage. Les températures trachéale et œsophagienne ont été enregistrées à des intervalles de 15 minutes jusqu'à la fin de la chirurgie. Les températures des deux appareils ont été analysées à l'aide d'une analyse de Bland-Altman, de diagrammes à quatre quadrants et de diagrammes polaires. RéSULTATS: Nous avons analysé 261 points de données provenant de 36 patient·es. Les plages de température allaient de 34,2 °C à 36,6 °C pour la sonde trachéale de température et de 34,7 °C à 37,2 °C pour la sonde thermique œsophagienne. L'analyse de Bland-Altman a montré une concordance acceptable entre les deux dispositifs, avec un biais moyen global (limite de 95 % de la concordance) de −0,3 °C (−0,8 °C à 0,1 °C) et un pourcentage d'erreur de 3 %; la capacité de tendance (changements de température au fil du temps) entre les deux dispositifs a montré un taux de concordance de 94 % dans un diagramme à quatre quadrants (limite ≥ 92 %), mais cette capacité était plus élevée que le biais angulaire moyen acceptable de 177° (limite < ± 5°) et que les limites radiales de l'accord de 52° (limite < ± 30°) dans le diagramme polaire. La bronchoscopie réalisée lors de l'extubation et les entretiens avec les patient·es six heures après l'opération n'ont révélé aucune blessure grave liée à l'utilisation de la sonde trachéale de température. CONCLUSION: La sonde trachéale de température a montré un biais moyen global acceptable de −0,3 °C et un pourcentage d'erreur de 3 %, mais une capacité de tendance incompatible avec la sonde thermique œsophagienne. ENREGISTREMENT DE L'éTUDE: cris.nih.go.kr (KCT0007265); 22 avril 2022.


Asunto(s)
Laparoscopía , Tráquea , Humanos , Temperatura , Temperatura Corporal , Intubación Intratraqueal
16.
Small ; 20(30): e2400038, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38402430

RESUMEN

Development of synthetic strategies selectively yielding single crystals is desired owing to the facet-dependent chemical reactivities. Recent advances in electrochemical materials synthesis yielded nanomaterials that are surfactant-free, however, typically in polycrystalline forms. In this work, an electrochemical synthetic strategy selectively yielding single-crystalline nanoparticles by implementation of surface-selective heating of the working electrode is developed. Single crystals of copper, silver, gold, and platinum are afforded, and the crystallinity verified by electron diffraction and chemical reactivity studies. Notably, Cu (100) surface prepared by electrochemical synthesis yielded high single product selectivity when applied to electrochemical CO2 reduction catalysis.

17.
Anesth Analg ; 139(3): 562-570, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38412113

RESUMEN

BACKGROUND: The effect of sevoflurane on left ventricular diastolic function is not well understood. We hypothesized that parameters of diastolic function may improve under sevoflurane anesthesia in patients with preexisting diastolic dysfunction compared to patients with normal diastolic function. METHODS: This observational study included 60 patients undergoing breast surgery or laparoscopic cholecystectomy. Patients were assigned to diastolic dysfunction (n = 34) or normal (n = 26) groups of septal e' < 8 or ≥ 8.0 cm/s on the first thoracic echocardiography (TTE) performed before anesthesia. During anesthesia, sevoflurane was maintained at 1 to 2 minimum alveolar concentration (MAC) to maintain the bispectral index at 40 to 50. At the end of surgery, the second TTE was performed under 0.8 to 1 MAC of sevoflurane with the patient breathing spontaneously without ventilator support. Primary end point was the percentage change (Δ) of e' on 2 TTEs (Δe'). Secondary end points were ΔE/e', Δleft atrial volume index (ΔLAVI), and Δtricuspid regurgitation maximum velocity (ΔTR Vmax). These percentage changes (Δ) were compared between diastolic dysfunction and normal groups. RESULTS: e' (Δe': 30 [6, 64] vs 0 [-18, 11]%; P < .001), mitral inflow E wave velocity (E), mitral inflow E/A ratio (E/A), and mitral E velocity deceleration time (DT) improved significantly in diastolic dysfunction group compared to normal group. LAVI decreased in diastolic dysfunction group but did not reach statistical significance between the 2 groups (ΔLAVI:-15 [-31, -3] vs -4 [-20, 10]%, P = .091). ΔE/e' was not different between the 2 groups (11 [-16, 26] vs 12 [-9, 22]%, P = .853) (all: median [interquartile range, IQR]). TR was minimal in both groups. CONCLUSIONS: In this study, echocardiographic parameters of diastolic function, including septal e', E, E/A, and DT, improved with sevoflurane anesthesia in patients with preexisting diastolic dysfunction, but remained unchanged in patients with normal diastolic function.


Asunto(s)
Anestésicos por Inhalación , Diástole , Sevoflurano , Función Ventricular Izquierda , Humanos , Sevoflurano/administración & dosificación , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Anestésicos por Inhalación/administración & dosificación , Diástole/efectos de los fármacos , Masculino , Anciano , Función Ventricular Izquierda/efectos de los fármacos , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Éteres Metílicos/administración & dosificación , Colecistectomía Laparoscópica , Adulto
18.
Sci Rep ; 14(1): 3864, 2024 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-38366042

RESUMEN

We aimed to evaluate the feasibility of MR elastography (MRE) using a transpelvic approach. Thirty-one patients who underwent prostate MRE and had a pathological diagnosis were included in this study. MRE was obtained using a passive driver placed at the umbilicus and iliac crests. The shear stiffness, clinical data, and conventional imaging findings of prostate cancer and benign prostatic hyperplasia (BPH) were compared. Inter-reader agreements were evaluated using the intraclass coefficient class (ICC). Prostate MRE was successfully performed for all patients (100% technical success rate). Nineteen cancer and 10 BPH lesions were visualized on MRE. The mean shear stiffness of cancer was significantly higher than that of BPH (5.99 ± 1.46 kPa vs. 4.67 ± 1.54 kPa, p = 0.045). One cancer was detected on MRE but not on conventional sequences. Six tiny cancer lesions were not visualized on MRE. The mean size of cancers that were not detected on MRE was smaller than that of cancers that were visible on MRE (0.8 ± 0.3 cm vs. 2.3 ± 1.8 cm, p = 0.001). The inter-reader agreement for interpreting MRE was excellent (ICC = 0.95). Prostate MRE with transpelvic vibration is feasible without intracavitary actuators. Transpelvic prostate MRE is reliable for detecting focal lesions, including clinically significant prostate cancer and BPH.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hiperplasia Prostática , Neoplasias de la Próstata , Masculino , Humanos , Próstata/diagnóstico por imagen , Vibración , Diagnóstico por Imagen de Elasticidad/métodos , Estudios de Factibilidad , Hiperplasia Prostática/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos
19.
Ann Pharmacother ; 58(4): 383-390, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37401103

RESUMEN

BACKGROUND: Only some studies have directly compared and analyzed the roles of activated partial thromboplastin time (aPTT) and activated clotting time (ACT) in coagulation monitoring during argatroban administration. OBJECTIVES: This study aims to assess the correlation of argatroban dose with ACT and aPTT values and to identify the optimal coagulation test for argatroban dose adjustment. METHODS: We evaluated 55 patients on extracorporeal membrane oxygenation (ECMO) who received argatroban for more than 72 hours. The correlation between argatroban dose and aPTT and ACT values was evaluated. To compare argatroban dose and bleeding events according to liver dysfunction, the patients were divided into 2 groups based on alanine aminotransferase and total bilirubin. RESULTS: Among the 55 patients, a total of 459 doses and coagulation tests were evaluated. The aPTT and ACT values showed a weak correlation with argatroban dose, with the Pearson correlation coefficients of 0.261 (P < 0.001) and 0.194 (P = 0.001), respectively. The agreement between the target 150 to 180 seconds for ACT and 55 to 75 seconds for aPTT was observed in 140 patients (46.1%). Twenty-four patients (43.6%) had liver dysfunction when they started argatroban. The median argatroban dose was lower in the liver dysfunction group than in the control group (0.094 mcg/kg/min vs 0.169 mcg/kg/min, P = 0.020). Difference was not observed between the 2 groups in the amount of red blood cell (0.47 vs 0.43 pack, P = 0.909) and platelet (0.60 vs 0.08 pack, P = 0.079) transfusion per day. CONCLUSION AND RELEVANCE: A weak correlation was observed between argatroban dose and the aPTT and ACT values. However, the agreement between aPTT and ACT was only 46.1% regarding the scope of target range. Further research is necessary to determine how to assess the optimal argatroban dose for patients administered argatroban while undergoing ECMO at the intensive care unit.


Asunto(s)
Arginina/análogos & derivados , Oxigenación por Membrana Extracorpórea , Hepatopatías , Sulfonamidas , Humanos , Tiempo de Tromboplastina Parcial , Heparina/efectos adversos , Anticoagulantes/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Ácidos Pipecólicos
20.
Anesthesiology ; 140(5): 920-934, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38109657

RESUMEN

BACKGROUND: Mechanical power (MP), the rate of mechanical energy (ME) delivery, is a recently introduced unifying ventilator parameter consisting of tidal volume, airway pressures, and respiratory rates, which predicts pulmonary complications in several clinical contexts. However, ME has not been previously studied in the perioperative context, and neither parameter has been studied in the context of thoracic surgery utilizing one-lung ventilation. METHODS: The relationships between ME variables and postoperative pulmonary complications were evaluated in this post hoc analysis of data from a multicenter randomized clinical trial of lung resection surgery conducted between 2020 and 2021 (n = 1,170). Time-weighted average MP and ME (the area under the MP time curve) were obtained for individual patients. The primary analysis was the association of time-weighted average MP and ME with pulmonary complications within 7 postoperative days. Multivariable logistic regression was performed to examine the relationships between energy variables and the primary outcome. RESULTS: In 1,055 patients analyzed, pulmonary complications occurred in 41% (431 of 1,055). The median (interquartile ranges) ME and time-weighted average MP in patients who developed postoperative pulmonary complications versus those who did not were 1,146 (811 to 1,530) J versus 924 (730 to 1,240) J (P < 0.001), and 6.9 (5.5 to 8.7) J/min versus 6.7 (5.2 to 8.5) J/min (P = 0.091), respectively. ME was independently associated with postoperative pulmonary complications (ORadjusted, 1.44 [95% CI, 1.16 to 1.80]; P = 0.001). However, the association between time-weighted average MP and postoperative pulmonary complications was time-dependent, and time-weighted average MP was significantly associated with postoperative pulmonary complications in cases utilizing longer periods of mechanical ventilation (210 min or greater; ORadjusted, 1.46 [95% CI, 1.11 to 1.93]; P = 0.007). Normalization of ME and time-weighted average MP either to predicted body weight or to respiratory system compliance did not alter these associations. CONCLUSIONS: ME and, in cases requiring longer periods of mechanical ventilation, MP were independently associated with postoperative pulmonary complications in thoracic surgery.


Asunto(s)
Ventilación Unipulmonar , Respiración con Presión Positiva , Humanos , Respiración con Presión Positiva/efectos adversos , Pulmón , Respiración Artificial/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Volumen de Ventilación Pulmonar , Ventilación Unipulmonar/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA