Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 12(11)2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36421141

RESUMEN

Both passive and active microfluidic chips are used in many biomedical and chemical applications to support fluid mixing, particle manipulations, and signal detection. Passive microfluidic devices are geometry-dependent, and their uses are rather limited. Active microfluidic devices include sensors or detectors that transduce chemical, biological, and physical changes into electrical or optical signals. Also, they are transduction devices that detect biological and chemical changes in biomedical applications, and they are highly versatile microfluidic tools for disease diagnosis and organ modeling. This review provides a comprehensive overview of the significant advances that have been made in the development of microfluidics devices. We will discuss the function of microfluidic devices as micromixers or as sorters of cells and substances (e.g., microfiltration, flow or displacement, and trapping). Microfluidic devices are fabricated using a range of techniques, including molding, etching, three-dimensional printing, and nanofabrication. Their broad utility lies in the detection of diagnostic biomarkers and organ-on-chip approaches that permit disease modeling in cancer, as well as uses in neurological, cardiovascular, hepatic, and pulmonary diseases. Biosensor applications allow for point-of-care testing, using assays based on enzymes, nanozymes, antibodies, or nucleic acids (DNA or RNA). An anticipated development in the field includes the optimization of techniques for the fabrication of microfluidic devices using biocompatible materials. These developments will increase biomedical versatility, reduce diagnostic costs, and accelerate diagnosis time of microfluidics technology.


Asunto(s)
Técnicas Biosensibles , Técnicas Analíticas Microfluídicas , Microfluídica , Dispositivos Laboratorio en un Chip , ADN
2.
Micromachines (Basel) ; 11(8)2020 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-32751989

RESUMEN

Piezoelectric micro-pumps offer many applications and could provide considerable flow rates in miniature systems. This study parametrically investigates the effects of major parameters, namely the length, width and attack angle of valves, piezoelectric length, and applied voltage. The results show that these parameters significantly affect the performance of the designed micro-pump. Even though increasing the piezoelectric length and operating voltage raise the flow rate, the modification of valve dimensions is more efficient since these parameters do not rely on any external power. According to the obtained results, as the length of the working valves increases, the provided flow rate becomes larger. There is an optimum condition for the width and attack angle of the valves. This optimum width is not dependent on the flow rate. With the use of the attack angle and the length of the valves as design parameters, the studied design shows promising results.

3.
Micromachines (Basel) ; 11(4)2020 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-32295138

RESUMEN

Label-free, size-dependent cell-sorting applications based on inertial focusing phenomena have attracted much interest during the last decade. The separation capability heavily depends on the precision of microparticle focusing. In this study, five-loop spiral microchannels with a height of 90 µm and a width of 500 µm are introduced. Unlike their original spiral counterparts, these channels have elliptic configurations of varying initial aspect ratios, namely major axis to minor axis ratios of 3:2, 11:9, 9:11, and 2:3. Accordingly, the curvature of these configurations increases in a curvilinear manner through the channel. The effects of the alternating curvature and channel Reynolds number on the focusing of fluorescent microparticles with sizes of 10 and 20 µm in the prepared suspensions were investigated. At volumetric flow rates between 0.5 and 3.5 mL/min (allowing separation), each channel was tested to collect samples at the designated outlets. Then, these samples were analyzed by counting the particles. These curved channels were capable of separating 20 and 10 µm particles with total yields up to approximately 95% and 90%, respectively. The results exhibited that the level of enrichment and the focusing behavior of the proposed configurations are promising compared to the existing microfluidic channel configurations.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA