Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rep Pract Oncol Radiother ; 29(2): 176-186, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39143974

RESUMEN

Background: Daily image-guided radiotherapy (IGRT) and deep inspiration breath hold (DIBH) technique are recommended for locoregional RT of breast cancer. The optimal workflow for a combination of surface-guided RT (SGRT) with DIBH technique is of current clinical interest. Materials and methods: The setup accuracy at three hospitals was evaluated using different SGRT workflows. A total of 150 patients (2269 image pairs) were analyzed in three groups: patient setup with the AlignRT® SGRT system in Tampere (Site 1, n = 50), the Catalyst™ SGRT system in Turku (Site 2, n = 50) and the Catalyst™ SGRT system in Jönköping (Site 3, n = 50). Each site used their routine workflow with SGRT-based setup and IGRT positioning. Residual errors of the bony chest wall, thoracic vertebra (Th 1) and humeral head were evaluated using IGRT images. Results: Systematic residual errors in the cranio-caudal (CC) direction and in pitch were generally larger at Site 2 than those at Sites 1 and 3 (p = 0.01-0.7). With daily IGRT, only a small difference (p = 0.01-0.9) was observed in residual random errors of bony structures in other directions between sites. Conclusion: The introduction of SGRT and the use of daily IGRT lead to small residual errors when combining the best workflow practices from different hospitals. Our multicenter evaluation led to improved workflow by tightening the SGRT tolerances on Site 2 and fixation modification. Because of mainly small random errors, systematic posture errors in the images need to be corrected after posture correction with new setup surfaces. We recommend tight SGRT tolerances, good fixation and correction of systematic errors.

2.
Rep Pract Oncol Radiother ; 27(5): 797-808, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36523797

RESUMEN

Background: In locoregional radiotherapy of breast cancer with deep inspiration breath hold (DIBH), setup accuracy may depend on hospital protocol. At present, comparison between different positioning devices is challenging due to differing hospital protocols. The aim of this study was to evaluate the setup accuracy obtained with surface-guided radiation therapy (SGRT; AlignRT®, Catalyst™) or with lasers and real-time position management (RPM™) in DIBH. Materials and methods: A total of 1692 image pairs were analyzed in three groups: positioning using AlignRT® surface guidance system (Group A, n = 45), Catalyst™ (Group C, n = 50) and conventional lasers and tattoos (Group L, n = 46). We evaluated residual errors for the bony chest wall, th1 and humeral head in kV images with laser- or SGRT-based setup with and without daily image-guided radiation therapy (IGRT). Results: Less isocenter variance was found in Group A than in Group L or C (p ≤ 0.05) and in Group C than in L (p = 0.02-0.6). With SGRT only, the smallest random rotation error was found in Group A (p = 0.01). With daily IGRT, only a small difference was found for residual errors between the groups. Conclusion: Setup with SGRT improves the isocenter reproducibility compared to lasers and RPM™. Only small differences were found in setup accuracy between the SGRT devices. Due to improved isocenter accuracy, daily orthogonal IGRT is suggested in all the groups.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA