Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Neurointerv Surg ; 9(7): 686-688, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28108500

RESUMEN

The Pipeline Embolization Device (PED) is a flow diverting stent used in the treatment of a wide variety of intracranial aneurysms. The device differs from traditional stents used in stent-assisted coil embolization in that it has a tighter lattice structure with smaller cell sizes designed specifically to disrupt blood flow into aneurysms rather than only to retain coils within aneurysms. While the PED has been shown to be safe and effective, it has a unique risk profile that includes side branch and perforator vessel occlusion. Side branch occlusion in particular has been noted in several articles to occur at a relatively high rate with coverage of the ophthalmic artery origin by the PED. In this series, we present two cases of ophthalmic artery occlusion after PED placement with reconstitution of flow via an endoleak.


Asunto(s)
Trastornos Cerebrovasculares/diagnóstico por imagen , Embolización Terapéutica/efectos adversos , Endofuga/diagnóstico por imagen , Arteria Oftálmica/diagnóstico por imagen , Stents/efectos adversos , Anciano , Prótesis Vascular/efectos adversos , Trastornos Cerebrovasculares/etiología , Trastornos Cerebrovasculares/cirugía , Embolización Terapéutica/instrumentación , Endofuga/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Oftálmica/cirugía , Resultado del Tratamiento
2.
J Glaucoma ; 18(4): 305-10, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19365196

RESUMEN

OBJECTIVE: To determine and compare variance components in linear cup-to-disc ratio (LCDR) estimates by computer-assisted planimetry by human experts, and automated machine algorithm (digital automated planimetry). DESIGN: Prospective case series for evaluation of planimetry. PARTICIPANTS: Forty-four eyes of 44 consecutive patients from the outpatient Glaucoma Service at University of Iowa with diagnosis of glaucoma or glaucoma suspect were studied. METHODS: Six stereo pairs of optic nerve photographs were taken per eye: 3 repeat stereo pairs using simultaneous fixed-stereo base fundus camera (Nidek 3Dx) and another 3 repeat stereo pairs using sequential variable-stereo base fundus camera (Zeiss). Each optic disc stereo pair was digitized and segmented into cup and rim by 3 glaucoma specialists (computer-assisted planimetry) and using a computer algorithm (digital automated planimetry), and LCDR was calculated for each segmentation (either specialist or algorithm). A linear mixed model was used to estimate mean, SD, and variance components of measurements. MAIN OUTCOME MEASURES: Average LCDR, interobserver, interrepeat, intercamera coefficients of variation (CV) of LCDR and their 95% tolerance limits. RESULTS: There was a significant difference in LCDR estimates among the 3 glaucoma specialists. The interobserver CV of 10.65% was larger than interrepeat (6.7%) or intercamera CV (7.6%). For the algorithm, the LCDR estimate was significantly higher for simultaneous stereo fundus images (Nidek, mean: 0.66) than for sequential stereo fundus images (Zeiss, mean: 0.64), whereas interrepeat CV for Nidek (4.4%) was lower than Zeiss (6.36%); the algorithm's interrepeat and intercamera CV were 5.47% and 7.26%, respectively. CONCLUSIONS: Interobserver variability was the largest source of variation for glaucoma specialists, whereas their interrepeat and intercamera variability is comparable with that of the algorithm. DAP reduces variability on LCDR estimates from simultaneous stereo images, such as the Nidek 3Dx.


Asunto(s)
Glaucoma/diagnóstico , Interpretación de Imagen Asistida por Computador/métodos , Disco Óptico/patología , Enfermedades del Nervio Óptico/diagnóstico , Fotograbar/métodos , Algoritmos , Femenino , Fondo de Ojo , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos
3.
Psychiatry Res ; 163(3): 193-200, 2008 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-18656332

RESUMEN

Connections of the cortical-thalamic-cerebellar-cortical regions provide a framework for studying the neural substrates of schizophrenia. A novel diffusion tensor tractography method was used to evaluate the differences in white matter connectivity between 12 patients with schizophrenia and 10 controls. For the tract tracing, we focused on the connection between the cerebellum and the thalamus. Fractional anisotropy (FA) measures along the fiber tracks were compared between patients and the control sample. Fiber tracts located between the cerebellar white matter and the thalamus exhibit a reduced FA in patients with schizophrenia in comparison with controls. The FA values along the defined fiber tracts were not overall reduced but exhibited a reduction in the anisotropy in the region in the superior cerebellar peduncles projecting towards the red nucleus.


Asunto(s)
Cerebelo/fisiopatología , Imagen de Difusión por Resonancia Magnética , Red Nerviosa/fisiopatología , Esquizofrenia/fisiopatología , Tálamo/fisiopatología , Adulto , Anisotropía , Manual Diagnóstico y Estadístico de los Trastornos Mentales , Femenino , Humanos , Masculino , Proyectos Piloto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA