Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Catheter. cardiovasc. interv ; 98(7): 1335-1342, Dec. 2021. ilus, graf, tab
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352807

RESUMEN

ABSTRACT AIMS: The aim of SiBi study was to evaluate the early vascular healing and neointimal coverage after implantation of ultrathin (60 µm) biodegradable polymer-coated Tetriflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent (SES) using optical coherence tomography (OCT) at 4 to 6 weeks after implantation. METHODS: SiBi was a single-center, observational, investigator-initiated study. From January 15, 2018 to April 15, 2018, total 29 consecutive patients who had consented and underwent OCT examination at 4­6 weeks after Tetriflex SES implantation were enrolled. All OCT images were analyzed at an independent core laboratory by analysts who were blinded to patient and procedural information. RESULTS: Of 29 patients, four patients were excluded, as those OCT images were technically inadequate for analysis. Therefore, 25 patients were included in final OCT analysis. Average OCT analysis was performed after 35.3 ± 5 days of Tetriflex implantation. Total 14,024 stent struts in 1,520 cross sections were analyzed. Strut tissue coverage was observed in 91.26 ± 5.53% of struts and malapposed struts were seen in 0.89 ± 1.67%. The mean neointimal hyperplasia (NIH) thickness on the covered struts was 50 ± 30 µm. CONCLUSION: A large percentage of struts were found to be covered with thin layer of NIH evenly distributed along the stent length at around 1 month from stent implantation. The results of this pilot study serve as ethical and scientific backbone to conduct an adequately powered clinical trial to evaluate outcomes of short dual-antiplatelet therapy in context of ultrathin strut stent.


Asunto(s)
Stents , Sirolimus , Tomografía de Coherencia Óptica
2.
BMJ Open ; 6(2): e010028, 2016 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-26888727

RESUMEN

OBJECTIVES: To evaluate, in the FLEX Registry, clinical outcomes of an ultrathin (60 µm) biodegradable polymer-coated Supraflex sirolimus-eluting stent (SES) for the treatment of coronary artery disease. Additionally, to determine the vascular response to the Supraflex SES through optical coherence tomography (OCT) analysis. SETTING: Multicentre, single-arm, all-comers, observational registry of patients who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. PARTICIPANTS: 995 patients (1242 lesions) who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. A total of 47 participants underwent OCT analysis at 6 months' follow-up. INTERVENTIONS: Percutaneous coronary intervention with Supraflex SES, PRIMARY AND SECONDARY OUTCOME MEASURES: The primary endpoint-the rate of major adverse cardiac events (defined as a composite of cardiac death, myocardial infarction (MI), target lesion revascularisation (TLR))-was analysed during 12 months. RESULTS: At 12 months, the primary endpoint occurred in 36 (3.7%) of 980 patients, consisting of 18 (1.8%) cardiac deaths, 16 (1.6%) MI, 7 (0.7%) TLR and 2 (0.2%) cases of non-target lesion target vessel revascularization. In a subset of 47 patients, 1227 cross-sections (9309 struts) were analysed at 6 months by OCT. Overall, a high percentage of struts was covered (98.1%), with a mean neointimal thickness of 0.13 ± 0.06 µm. CONCLUSIONS: The FLEX Registry evaluated clinical outcomes in real-world and more complex cohorts and thus provides evidence that the Supraflex SEX can be used safely and routinely in a broader percutaneous coronary intervention population. Also, the Supraflex SES showed high percentage of stent strut coverage and good stent apposition during OCT follow-up.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Sistema de Registros , Sirolimus/administración & dosificación , Implantes Absorbibles , Anciano , Enfermedades Cardiovasculares/mortalidad , Femenino , Humanos , India , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Revascularización Miocárdica/estadística & datos numéricos , Neointima/patología , Polímeros , Tomografía de Coherencia Óptica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA