Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Asunto principal
Intervalo de año de publicación
1.
Cureus ; 15(8): e43500, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37719625

RESUMEN

Stereotactic ablative radiotherapy (SABR) is a possible treatment option for patients who develop recurrence within or at the edge of a previously irradiated volume. Robotic stereotactic radiotherapy is the result of technological advances in robotic precision, real-time imaging, non-invasive, highly customizable treatment plan, and delivery with sub-millimeter accuracy. This article reviews the radiobiologic, technical, and clinical aspects of robotic-based SABR re-irradiation for various anatomical sites. An extensive literature search was performed to identify articles on the utilization of robotic stereotactic radiotherapy for patients undergoing re-irradiation. The reported prescription dose and fractionation data along with outcomes such as overall survival, local control rates, and toxicities were qualitatively reviewed. The findings consistently indicate that re-irradiation using robotic SABR provides encouraging survival rates with minimal toxicity in the clinical setting of various anatomical sites delivered using locally non-invasive means where other treatment options are scarce.

2.
Cureus ; 15(5): e39600, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37384098

RESUMEN

The objective of this research is to conduct a comprehensive bibliometric analysis using the Web of Science Core Collection (WoSCC) to examine the current research topics and trends pertaining to stereotactic-based re-irradiation. A bibliometric search was conducted for re-irradiation-related literature published in English from the WoSCC database from 1991 to 2022, using VOSviewer to visualize the results. The extracted information comprises the publication year, overall citation count, average citation rate, keywords, and research domains. We conducted a literature review to identify trends in research on re-irradiation. A total of 19,891 citations were found in 924 qualifying papers that came from 48 different nations. The number of publications and citations has grown steadily since 2008 with the highest number of publications in the year 2018. Similarly, a substantial increase in the number of citations has increased since 2004 and the citation growth rate has been positive between 2004 and 2019 with a peak in 2013. The top authorship patterns were six authors (111 publications and 2498 citations), whereas the highest number of citations per publication was attained with an authorship pattern of 17 authors (C/P = 41.1). The collaboration patterns analysis showed that the largest proportion of publications emanated from the United States with 363 publications (30.9%), followed by Germany with 102 publications (8.7%), and France with 92 publications (7.8%). The majority of the analyzed studies were focused on the brain (30%), head and neck (13%), lung (12%), and spine (10%) and there have been emerging studies on the use of re-irradiation for lung, prostate, pelvic and liver utilizing stereotactic radiotherapy. The main areas of interest have changed over time and are now based on a multidisciplinary approach that integrates advanced imaging techniques, stereotactic treatment delivery, the toxicity of organs at risk, quality of life, and treatment outcomes.

3.
Radiol Phys Technol ; 16(1): 109-117, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36729272

RESUMEN

In a brachytherapy room irradiated with an Iridium-192 (192Ir) source, the spatial distributions of photon dose rates were measured and calculated for the dose distribution both inside and outside the room. The spatial distributions were measured using a thermoluminescent dosimeter (LiF-100) on the surfaces of the concrete walls and barriers of the irradiation room. The calculations were performed using the particle and heavy ion transport code system (PHITS) by considering the detailed model of the brachytherapy room and the radiation source used in the measurements. The measured and calculated doses exhibited a similar distribution pattern within and outside the brachytherapy room. To reduce the edge effect at the entrance door, the addition of a 3-mm thick lead layer on the surface of the concrete wall on the left doorstop is recommended. For the 60Co source, with the existing walls and lead door thickness, the dose at the control console and in front of the entrance maze increased by a factor of approximately 60.


Asunto(s)
Braquiterapia , Dosimetría Termoluminiscente , Dosificación Radioterapéutica , Fotones/uso terapéutico , Método de Montecarlo
4.
Heliyon ; 9(1): e13032, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36711293

RESUMEN

Biodegradable adhesives prepared using three different forms of soy protein-based products (defatted soy flour/soy protein concentrate/soy protein isolate), sodium hydroxide, and itaconic acid polyamidoamine-epichlorohydrin (IA-PAE) with 0 wt%-20 wt% substitution rates were utilized to enhance the production of mangrove wood composites. 1H nuclear magnetic resonance, differential scanning calorimetry, and ultra-high-resolution field emission scanning electron microscopy were employed to characterize the composite samples. Other measurements involved the determination of viscosity, pH, physical, mechanical, dimensional stability, CT numbers, and relative electron density parameters. The ideal curing conditions for the composite bio-adhesives were found to be 15 wt% IA-PAE, 602.50 ± 172.21-391.11 ± 105.82 mPa s, pH 11.0, 180 °C, and 18 min, respectively. The improved physiochemical characteristics of DSF, SPC, and SPI confirmed that NaOH/IA-PAE was integrated into the adhesive system and ameliorated the overall performance of the resulting composites. The results showed that all composite samples, except for those bonded with 0 wt% and 5 wt% IA-PAE, matched up with the quality specification stated in the JIS A-5908 and ASTM D1037. Samples D1, D2, and D3 exhibited optimum characteristics, demonstrating their uses in the development of low-toxicity and sustainable reference tissue substitute phantom in radiological areas.

5.
Hepat Oncol ; 9(3): HEP44, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36176484

RESUMEN

Materials & methods: High dose rate interstitial brachytherapy (HDR-IBT) treatment plan for 15 metastatic liver lesions in a patient with pancreatic cancer was retrieved and analyzed for liver dose parameters and diaphragm dose. Serial 18F-FDG PET-CT scans were reviewed for disease response assessment and left liver lobe volume. Serial laboratory records were analyzed for liver parameters. Results: Left liver lobe volume increased from 241 cm3 pre-HDR-IBT to estimated 600 cm3 after seven sessions of HDR-IBT. Metabolic complete response (CR) and subsequently pathological CR was confirmed in the right hepatotectomy specimen for all the 15 PET-CT avid lesions treated with HDR-IBT. Maximum diaphragm dose in a single fraction was 82 Gy. The liver parameters were stable and patient did not develop radiation induced liver disease. Discussion: This is the largest reported series of HDR-IBT to liver lesions in a single patient. This first ever reported combined treatment of immunotherapy (IT) and HDR-IBT had likely rendered this patient disease free both at local the liver and systemically. Metabolic CR by PET-CT can be seen as early as 46 days after HDR-IBT. Diaphragm can tolerate very high doses of radiation and repeated treatment. Conclusion: In this patient HDR-IBT for multiple liver lesions with IT is well tolerated. PET-CT can be used for response assessment of HDR-IBT liver. Synergistic effect of IT with HDR-IBT and it's role as bridging for liver resection has clinical potential and should be further studied in prospective trials.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA