Semin Dial ; 27(2): E21-3, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24118583

RESUMEN

Percutaneous transluminal balloon angioplasty (PTA) is a commonly performed procedure for hemodialysis vascular access dysfunction including thrombosis. While PTA is generally safe, balloon rupture during the procedure is a potential complication. Because such a rupture can cause damage to the blood vessel, indication of an imminent balloon rupture might help avoid such a complication. This analysis reports on six PTA procedures that were complicated by balloon rupture. All cases demonstrated terminal (caudal/cranial) cinch deformation. There was a loss of sharp terminal tapering and its replacement with banana silhouette before the balloon rupture. Importantly, the contour deformation and balloon rupture occurred at a pressure that was lower than the rated burst pressure. The cinch deformity can be used as an indication for impending balloon rupture. We suggest deflation of balloons that demonstrate shape deformations to avoid vascular injury.


Asunto(s)
Angioplastia de Balón/instrumentación , Falla de Equipo , Adulto , Anciano , Femenino , Humanos , Complicaciones Intraoperatorias/prevención & control , Masculino , Persona de Mediana Edad
2.
Semin Dial ; 27(4): E38-41, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24262012

RESUMEN

Vessel diameter is objectively measured by a lead ruler positioned in the fluoroscopic field and software calibration during angioplasty. We conducted a prospective study to evaluate the accuracy of lead ruler determination of vessel diameter. Chronic hemodialysis patients undergoing an angioplasty procedure were included in this study (n = 37). Vessel diameter was determined by calibrating the fluoroscopy machine to a ruler with lead markers placed in the fluoroscopic field. The same calibration was used to measure the fully effaced angioplasty balloon in its intravascular location. We compared the measured balloon diameter with the actual (manufacturer's) diameter. The approximate depth of the ruler from the measured vessel was also determined. Angioplasty balloons appeared 13.75-40.83% (mean 25.8% ± 7.015) smaller than the actual size of the balloon (p < 0.0001) when measured using a calibrated fluoroscopic machine. There was a tendency toward the fact that the bigger the distance between the ruler and the vessel (that contained the angioplasty balloon), the more likely the technique underestimated the size of the angioplasty balloon. Lead ruler method underestimates the diameter of the vessel. Recognizing such a discrepancy is important when determining the size of an angioplasty balloon or endovascular stent.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Vasos Coronarios/cirugía , Fluoroscopía/métodos , Stents , Enfermedad Coronaria/cirugía , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados