Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Saudi Heart Assoc ; 35(1): 1-6, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37020971

RESUMEN

Carney complex is rare neoplastic disorder. Intracardiac myxoma presenting the most common non-cutaneous lesions in this complex. We are reporting a 31-year-old Saudi female known case of Carney complex presented with asymptomatic biatrial myxoma that was identified on routine transthoracic echocardiogram, and was successfully excised. However, these patients need a careful surveillance in order to detect any new masses and prevent their complications.

2.
Rev. bras. cir. cardiovasc ; 38(1): 37-42, Jan.-Feb. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1423067

RESUMEN

ABSTRACT Introduction: Bleeding after transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The predictive value of the HAS-BLED score in TAVR patients is still to be evaluated. We assessed the value of the HAS-BLED score to predict in-hospital bleeding and mortality after TAVR and the impact of diferent renal impairment definitions on the predictive value of the score system. Methods: We retrospectively included 574 patients who underwent TAVR at a single center. Study outcomes were 30-day mortality and the composite endpoint of major and life-threatening bleeding as defined by The Valve Academic Research Consortium-2. The predictive value of the HAS-BLED score was calculated and compared to a modified model. The performance of the score was compared using two definitions of renal impairment. Model discrimination was tested using C-statistic and the Net Reclassification Index. Results: Bleeding occurred in 78 patients (13.59%). HAS-BLED category 3 was a significant predictor of bleeding (OR: 1.99 ]1.18- 3.37], C-index: 0.56, P=0.01). C-index increased to 0.64 after adding body surface area and extracardiac arteriopathy to the model. The Net Reclassification Index showed an increase in the predic tive value of the model by 11.4% (P=0.002). The C-index increased to 0.61 using renal impairment definition based on creatinine clearance. Operative mortality was significantly associated with the HAS-BLED score (OR: 7.54 [95% CI: 2.73- 20.82], C-index: 0.73, P<0.001). Conclusion: The HAS-BLED score could be a good predictor of in-hospital mortality after TAVR. Its predictive value for bleeding was poor but improved by adding procedure-specific factors and using creatinine clearance to define renal impairment.

3.
Braz J Cardiovasc Surg ; 38(1): 37-42, 2023 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-36112738

RESUMEN

INTRODUCTION: Bleeding after transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The predictive value of the HAS-BLED score in TAVR patients is still to be evaluated. We assessed the value of the HAS-BLED score to predict in-hospital bleeding and mortality after TAVR and the impact of diferent renal impairment definitions on the predictive value of the score system. METHODS: We retrospectively included 574 patients who underwent TAVR at a single center. Study outcomes were 30-day mortality and the composite endpoint of major and life-threatening bleeding as defined by The Valve Academic Research Consortium-2. The predictive value of the HAS-BLED score was calculated and compared to a modified model. The performance of the score was compared using two definitions of renal impairment. Model discrimination was tested using C-statistic and the Net Reclassification Index. RESULTS: Bleeding occurred in 78 patients (13.59%). HAS-BLED category 3 was a significant predictor of bleeding (OR: 1.99 ]1.18- 3.37], C-index: 0.56, P=0.01). C-index increased to 0.64 after adding body surface area and extracardiac arteriopathy to the model. The Net Reclassification Index showed an increase in the predic tive value of the model by 11.4% (P=0.002). The C-index increased to 0.61 using renal impairment definition based on creatinine clearance. Operative mortality was significantly associated with the HAS-BLED score (OR: 7.54 [95% CI: 2.73- 20.82], C-index: 0.73, P<0.001). CONCLUSION: The HAS-BLED score could be a good predictor of in-hospital mortality after TAVR. Its predictive value for bleeding was poor but improved by adding procedure-specific factors and using creatinine clearance to define renal impairment.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Medición de Riesgo , Estudios Retrospectivos , Creatinina , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Hemorragia/etiología
4.
J Saudi Heart Assoc ; 33(1): 26-34, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33936938

RESUMEN

OBJECTIVES: Left ventricular diastolic dysfunction (LVDD) in patients undergoing transcatheter aortic valve replacement (TAVR) is associated with poor outcomes; however, the effect of its severity is controversial. We sought to assess the impact of diastolic dysfunction on hospital outcomes and survival after TAVR and identify prognostic factors. METHODS: We included patients who underwent TAVR for severe aortic stenosis with preexisting LVDD from 2009 to 2018 (n = 325). Patients with prior mitral valve surgery (n = 4), atrial fibrillation (n = 39), missing or poor baseline diastolic dysfunction assessment (n = 36) were excluded. The primary endpoint was all-cause mortality. 246 patients were included in the study. RESULTS: The median age was 80 years (25th and 75th percentiles:75-86.7), 154 (62.6%) were males and the median EuroSCORE II was 4.3 (2.2-8). Patients with severe LVDD had significantly higher EuroSCORE, and lower ejection fraction (p < 0.001). There was no difference in post-TAVR new atrial fibrillation (p = 0.912), pacemaker insertion (p = 0.528), stroke (p = 0.76), or hospital mortality (p = 0.95). Patients with severe LVDD had longer hospital stay (p = 0.036). The grade of LVDD did not affect survival (log-rank = 0.145) nor major adverse cardiovascular events (log-rank = 0.97). Predictors of mortality were; low BMI (HR: 0.95 (0.91-0.99); p = 0.019), low sodium (0.93 (0.82-2.5); p = 0.021), previous PCI (HR: 1.6 (1.022-2.66); p = 0.04), E-peak (HR: 1.01 (1.002-1.019); p = 0.014) and implantation of more than one device (HR: 3.55 (1.22-10.31); p = 0.02). CONCLUSION: Transcatheter aortic valve replacement is feasible in patients with diastolic dysfunction, and the degree of diastolic dysfunction did not negatively affect the outcome. Long-term outcomes in those patients were affected by the preoperative clinical state and procedure-related factors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA