RESUMEN
Flavivirus detection in humans and mosquito reservoirs has been an important issue since it can cause a variety of illnesses and could represent a health problem in geographical zones where the vector is endemic. In this work, we designed and characterized a biosensor based on gold nanoparticles (AuNPs) and antibody 4G2 for the detection of dengue virus (DENV) in vitro, obtaining different conjugates (with different antibody concentrations). The AuNP-4G2 conjugates at concentrations of 1, 3, and 6 µg/mL presented an increase in the average hydrodynamic diameter compared to the naked AuNPs. Also, as part of the characterization, differences in the UV-Vis absorbance spectrum and electrophoretic migration were observed between the conjugated AuNPs (with BSA or antibody) and naked AuNPs. Additionally, we used this biosensor (AuNP-4G2 conjugate with 3 µg/mL antibody) in the assembly of a competitive lateral flow assay (LFA) for the development of an alternative test to detect the flavivirus envelope protein in isolated DENV samples as a future tool for dengue detection (and other flaviviruses) in the mosquito vector (Aedesaegypti) for the identification of epidemic risk regions. Functionality tests were performed using Dengue virus 2 isolated solution (TCID50/mL = 4.58 × 103) as a positive sample and PBS buffer as a negative control. The results showed that it is possible to detect Dengue virus in vitro with this gold nanoparticle-based lateral flow assay with an estimated detection limit of 5.12 × 102 PFU. We suggest that this biosensor could be used as an additional detection tool by coupling it to different point-of-care tests (POCT) for the easy detection of other flaviviruses.
Asunto(s)
Técnicas Biosensibles , Virus del Dengue , Nanopartículas del Metal , Animales , Técnicas Biosensibles/métodos , Oro , Humanos , Inmunoensayo/métodosRESUMEN
The progression and distribution of the SARS-CoV-2 pandemic are continuously changing over time and can be traced by blood donors' serological survey. Here, we investigated the seroprevalence of anti-SARS-CoV-2 antibodies in blood donors in Nuevo Leon, Mexico during 2020 as a strategy for the rapid evaluation of the spread of SARS-CoV-2 and asymptomatic case detection. We collected residual plasma samples from blood donors who attended two regional donation centers from January to December of 2020 to identify changes in anti-SARS-CoV-2 IgG prevalence. Plasma samples were analyzed on the Abbott Architect instrument using the commercial Abbott SARS-CoV-2 IgG chemiluminescent assay. We found a total of 99 reactive samples from 2068 analyzed plasma samples, resulting in a raw prevalence of 4.87%. Donors aged 18-49 years were more likely to be seropositive compared to those aged >50 years (p < 0.001). Weekly seroprevalence increased from 1.8% during the early pandemic stage to 27.59% by the end of the year. Prevalence was 1.46-fold higher in females compared to males. Case geographical mapping showed that Monterrey city recorded the majority of SARS-CoV-2 cases. These results show that there is a growing trend of seroprevalence over time associated with asymptomatic infection that is unnoticed under the current epidemiological surveillance protocols.